PM Check and thus IBIS Fails for LVShim, but the Data Passes and SPT and LVShim were run within 24 hours of each other
Symptom
PM Check and thus IBIS Fails for LVShim, but the Data Passes and SPT and LVShim were run within 24 hours of each other PM Check, and thus IBIS, fails for LVShim but we don't know why, the data passes and the gap between SPT and LVShim was less than a day. In fact, the gap between the two tests was only eighteen minutes. We can see this in the time stamp on the files in /usr/g/service/data. Why then do we have this failure? -------------------------------------------------- Contents of PM_history file -------------------------------------------------- ***************************************************************** PM Assist Status : PM complete. ***************************************************************** SPT PM File Name : /usr/g/service/data/GCJK3353_PM.SPT ---------------------------------------------------------------- Head SNR : PASS Head FSE Stab : PASS Head GRE Stab : PASS Body SNR : PASS Body FSE Stab : PASS Body GRE Stab : PASS Coherent Noise : PASS Eddy Current X : PASS Eddy Current Y : PASS Eddy Current Z : PASS LVS PM FILE NAME : /usr/g/service/data/GCJK51RC.LVS ---------------------------------------------------------------- LV Shim : FAIL EPI White Pixel PM FILE NAME : /usr/g/service/data/G4OJ3913_PM.EPT ------------------------------------------------- Head White Pixel : PASS Body White Pixel : PASS Please Fix the SEVERE Failures (except for EPIWP tests ) before : 1/9/2007 Last & Next scheduled PM dates --------------------------------- LAST PM DATE : 12/19/2006 Next PM is DUE by : 2/28/2007 PM Status: ON TIME
Error message
THE GAP BETWEEN SPT & LVS PM DATA FILES IS MORE THAN A DAY, Exiting PM Check Failure. THE GAP BETWEEN SPT & LVS PM DATA FILES IS MORE THAN A DAY, Exiting
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.