Unable to Scan with 1.0T CTLBOT due to Multi-Coil T/R Driver Fault.
Symptom
Unable to Scan with 1.0T CTLBOT due to Multi-Coil T/R Driver Fault 1.0T 5X Horizon system unable to scan with the CTLBOT coil definition using the CTL coil, due to error 2225558 "Multi-Coil T/R Driver Fault. A short circuit was detected on port 4". (See Long Description for complete error message). All other coil definitions work with this coil. Also FE replaced the coil and has the same error with the new coil. The Coil Config entry in /w/config/CoilConfig.cfg is correct. 1.0T 5X Horizon system unable to scan with the CTLBOT coil definition using the CTL coil, due to error 2225558 "Multi-Coil T/R Driver Fault. A short circuit was detected on port 4". (See below for complete error message). All other coil definitions work with this coil. Also FE replaced the coil and has the same error with the new coil. The Coil Config entry in /w/config//CoilConfig.cfg is correct. Wed Mar 28 12:26:42 2007 2225558 1 MR01 OC0 HPC_PORT_ID PMH.m 1.29 spi_tr_mon 6310 Multi-Coil T/R Driver Fault. A short circuit was detected on port 4. Check cable to multi-coil board or check for a shorted pin diode. Wed Mar 28 12:26:43 2007 2224583 2 MR01 OC0 MSG_HANDLR0 PMH.m 1.29 aps_cf 15 Auto Prescan failed, possible data acquisition failure.
Error message
2224583 Auto Prescan Failed, Possible Data Acquisition Failure. File: APS:aps_cf Line: 15 Auto Prescan failed, possible data acquisition failure. 2225558 Multi-Coil T/R Driver Fault. A short circuit was detected on port 4. Check cable to multi-coil board or check for a shorted pin diode. 2225558 MR01 OC0 HPC_PORT_ID PMH.m 1.29 spi_tr_mon 6310 Multi-Coil T/R Driver Fault. A short circuit was detected on port 4. Check cable to multi-coil board or check for a shorted pin diode.
Applies to
- Models
- Signa
- Product
- Signa Horizon (5X Horizon) 5X Horizon systems
- Software
- 5.X
- Component
- 46-328371P1 CABLE ASM RUN 736 MG3–A36–J19 TO MG2–A16–A8–J9 Cable Run # 736. This is the white MC Bias cable between the MULTI–COIL SELECT SWITCH J19 in the Rear Pedestal and MULTI–COIL PREAMP PROTECTION J9 in the HEAD COIL CARRIAGE ASSY. It is routed through the cable takeup. Cable Run # 736. This is the white MC Bias cable between the MULTI–COIL SELECT SWITCH J19 in the Rear Pedestal and MULTI–COIL PREAMP PROTECTION J9 in the HEAD COIL CARRIAGE ASSY. It is routed through the cable takeup.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.