GE X-ray R&F — field troubleshooting
3,432 field-service issues · page 1 of 43
Symptom, error message and equipment context for each GE X-ray R&F issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…X-ray R&F
- AEC Backup Time messageX-ray R&F
- New style ion chamber does not have a preampX-ray R&F · 2252611
- Precision 500D Table Fluoro Carriage Front Bumper is not properly adjusted, allows excessive travel toward the front of the table.X-ray R&F
- Precision 500D Aurora, dose readout does not update when an overhead Rad Tube Exposure is made, at any technic due to abnormally low mR/mAS from the Rad Overhead XRT.X-ray R&F
- P500D Aurora with M4 Software (May 2006 Release), Dose Readout Correct on Console, Dose Printer Prints 0.0 due to a M4 Software BugX-ray R&F
- Precision 500D Aurora, RCIM E-stop circuit is difficult to troubleshoot because there is no overall interconnect schematic from the RCIM operator console to the Corona 2 board in the System Cabinet.X-ray R&F
- Precision 500D Aurora system with Magic PC.X-ray R&F
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…X-ray R&F
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.X-ray R&F · 1000243
- Definium 8000 One or both monitors display the following message on every bootX-ray R&F
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.X-ray R&F · 3400017, 1090253
- Revolution XRd2X Worklist query on "All Systems in this Modality" does not retrieve anything after FMI 10791A is completed due to the default query set to DX.X-ray R&F
- MVP3 Intermittent Error 16 due to a Loose Wire in the MVP Generator Auxiliary Module.X-ray R&F
- P500D Siemens Collimator lamp voltage adjustment instructions missing due to documentation issues.X-ray R&F
- Definium 8000 OTS Collimator has no power due to a tripped breaker (CB8) ont he Tube Suspension Logic (TSL) Board.X-ray R&F
- Definium 8000 The Siemens Collimator has not power due to a tripped breaker (CB9) on the Tube Suspension Logic (TSL) Board.X-ray R&F
- Definium 8000 OTS movements have no power due to multiple tripped breakers on the OTS Tube Suspension Logic (TSL) Board.X-ray R&F
- Definium 8000 The OTS UIF has no power due to a tripped breaker (CB7) on the OTS Tube Suspension Logic (TSL) Board.X-ray R&F
- Definium 8000 OTS Locks have no power due to a tripped breaker (CB6) on OTS Tube Suspension Logic (TSL) Board.X-ray R&F
- No XRAY on large FocusX-ray R&F
- MPH or MPH+X-ray R&F
- Definium 8000 ThunderX-ray R&F
- Prestige AK Table Incorrect grid and cassette carriage motions during boot, other table motions very jerky, all due to a corrupt table calibration.X-ray R&F
- P500D Aurora install startup issueX-ray R&F · 1090115
- Precision MPI and RXI Software license key missing.X-ray R&F
- Revolution XR/d error 4280 when trying to make exposure to table or wallstand detectorX-ray R&F
- COLLIMATOR NOT COMMUNICATINGX-ray R&F
- incompatible issue between the DVD-Combo recorder and the CD-R media diskX-ray R&F · 5198015
- The part number for the vinyl – naugahyde flexible cover for XT and OTS hanger cable covers is 46-329261P1X-ray R&F
- Definium 5000 Hospital connection to the Magic PC Ethernet portX-ray R&F
- Definium 8000 Error 3400021 Unable to Fetch User Permissions since no Permission were Selected for User LoginX-ray R&F · 3400021
- Precision 500D No auto-collimationX-ray R&F
- Precision 500D Several bearings missing from the race within the bearing block.X-ray R&F
- Revolution XRd 2X The HP Workstation reboots itself.X-ray R&F
- Definium 8000 Error indicates collimator is rotated even though it is not due to an open lead in the TSL Asm.X-ray R&F · 600529
- Definium AMX700 stopped making exposures due to a broken wire on the back side of the power supply connector.X-ray R&F · 1201020
- Definium 8000 Volume Rad Imtermittently the rotor stays on after the PREP button is released.X-ray R&F
- DEFINIUM 8000 OTS High voltage cable connector requires silicon oil.X-ray R&F
- Precision RXi At some sites, Error 63 occurs after installing FMI 10794.X-ray R&F
- DRS Repeated Gel boards failure and intermittent DRS over-temperature error due to incorrect orientation of cabinet fans.X-ray R&F
- Precision RXi Cannot Fluoro in apps, no error reported in applications due to a defective cable between the CPI Generator and the Infimed Digital.X-ray R&F
- Definium 5000 The generator restore from backup CD never completes due to an incorrect switch setting on the ATP Console Board.X-ray R&F
- Definium 5000 The Def 5000 will only drive the gantry elevation in low speed due to an improperly miss adjusted Height Inverter.X-ray R&F
- MPH or MPH +X-ray R&F
- Precision 500D Angulation stops at 30-37 degrees during tilt of table due to insufficient power to the motor.X-ray R&F
- communication via ethernet interface fail.X-ray R&F · 5198015
- MPH or MPH + associated with Presige VH or SIX-ray R&F
- OTS SAFETY REEL REPLACEMENTX-ray R&F
- DICOM issues happened in hospitals, such as worklist query failure, etcX-ray R&F
- software issue when doing system restore in SUIF->Utilities->System->restoreX-ray R&F
- FEITIAN V15 INSITE PAGE NO DISPLAY ISSUEX-ray R&F
- Precision MPi Error E032 when trying to complete the heating calibrationX-ray R&F
- error 723 Anode rotation problem only in low speed .X-ray R&F
- ADXE RFX/SFX Legacy popping noises during angulation SN 3715X-ray R&F
- Definium 8000 Auto Positioning may fail to complete.X-ray R&F
- Definium 8000 Auto Protocol does not work after FMI 10808 / FMI 10810X-ray R&F
- Proteus - LED on Longitudinal SID sensor goes out while on the 72" SIDX-ray R&F
- Precision 500D Aurora, new installation.X-ray R&F
- RXI system, CPI generator reports error code 08 kV/mA fault, at any technique, with both X-Ray tubes.X-ray R&F
- Precision 500D, Aurora version (with Magic PC).X-ray R&F · 3800105
- Precision 500D error code 1100123 and 1100124 Failure to Setup Image Intensifier Optics with Debug text Neutral Density Filter Timeout during prep or after a digital record exposure.X-ray R&F · 1100123, 1100124
- P500D Service Engineer is unable to complete calibration Unit AV02 Image Intensifier Sizing and Focus due to corrupt values stored in the image intensifier high voltage power supply.X-ray R&F
- Advantx Rad Compax 40E system with SG100 Tilting Vertical Bucky Stand.X-ray R&F
- P500D Precision 500D Aurora version with HP computer.X-ray R&F
- Gene MPG 65 / 80 / 100X-ray R&F
- P500D Aurora Table E-STOP circuit is difficult to troubleshoot because there is no overall interconnect chart from the Table E-Stop red pushbutton switch to the Corona 2 board in the System Cabinet.X-ray R&F
- Precision 500D Aurora documentation does not provide an overall interconnect chart from the Jedi generator to the Table Ion Chamber.X-ray R&F
- Advantx Legacy system with DRS 3.2 with DRS Gateway.X-ray R&F
- The power on is OK but the console is blank .Change the fuse and if the fuse blown again , the pb is in the console .X-ray R&F
- No XRAY and red led flash on console .:Replace fuse F11 or circuit Command Gachettes .X-ray R&F
- No complete "Power On " .X-ray R&F
- Definium 5000 System will not completely power down when shutdown from the CRIBX-ray R&F
- All fuses F15 , F16 , F17 , F18 blown when you make a carriage .:Check fuses 2F24 and 2F25 .X-ray R&F
- Prestige VH and Prestige 2X-ray R&F
- Def8000, Def5000, Revolution XRd and XRD2X Latent lead marker image burned into the detector.X-ray R&F
- Revolution XRd2X, XRd, and XQi The chest stand counterweight belt part number is 2336380.X-ray R&F
- DRE Procedure to potentially recover an image accidentally deleted by the user.X-ray R&F
- Def8000 XRd2X The Customer is unable to print films from the Digital Rad system due to a corrupt printer configuration file.X-ray R&F
- Proteus Eclipse Collimator Renewal Parts are not readily available.X-ray R&F