GE MR — field troubleshooting
9,114 field-service issues · page 63 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Cannot DICOM Network Images Due to A back slash in the Protocol Name.MR · 11057
- Magnet Monitor 3 was not placed into Service Mode prior to Magnet or System Service.LCC_HMI2 ALARM I2 - CH RUO CBL OPEN.Use Magnet Monitor 3 Service Mode When Performing Magnet Service or System Servi…MR
- Where is MCQA Test Data Located on System.MR
- Language Pop Up Not Coming up Due to saveINFO media was in the mod drive while performing applications load.MR
- What are the Dicom Tag numbers and description in Numerical Order?MR
- Cradle Wheels Stick Due to Contrast in Wheel Bearings.MR · 2224727, 2224842
- CWA Concern about pop-up Message Application Disk Space Low, but System Scanning ok.MR
- CWA ILINQ test message received from customer site.MR
- CWA MRIQ Images are Grainy, Noisy Low SNRMR
- White Pixels Due to Contamination present on Magnet, Gradient Coil and CablesMR
- How to Add, Update, or Delete a Network Host.MR
- 183473 System Has A Failure That Could Significantly Degrade Image Quality, Pop Up Window at End of System Startup.MR · 2218672
- Time or date incorrect on wavetime PC.MR
- Need FRU PN for Handwheel Shaft used on OpenSpeed table.MR · 2261552
- Table Will Not Move in or Out Due to Swapped Cables.MR
- MRSPT SNR fails due to corrupted image database.MRSPT fails SNR with a negative SNR value.MR
- TR Driver Fault Detected Open Circuit Source of Fault is both Head TR and Body TR Due to Driver Module Lite.MR · 2224666, 2252305
- Unable to scan.MR · 2219628
- 2267910 Power cabinet reporting 48V overvoltage due to PS1 48 V supply in PDU.MR · 2267728, 2267600
- Oxygen Monitor needs to be Calibrated.MR
- TPS Reset Fails With Error 2267587 due to RRX ModuleMR · 2227556, 2267587
- Design of System.MR
- Errors 2261715 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level and Error 2256925 StartupCondition error on HWo due to signal box 5269691MR · 2256925, 2261715
- Rf amp response timeout due to SSM.MR · 2253822, 2248759
- SRI SCP Communication Error Due to SRI.MR · 2249110
- Archive Status shows No Due to Default Archive Device not set correctly.MR
- Will Not Scan with Gradient Errors.MR · 2245044, 2245053
- Will Not Scan With Current Distortion faults Due to Gradient Power SupplyMR · 2244848, 2244574
- Multi Coil Bias Faults Due to Bent Pins in Connector.MR · 2252293, 2224666
- Multicoil Bias Short or Open Faults Due to CableMR · 2274023
- Fails TPS Reset when booting up to Applications or when Resetting TPS Due to Scan Room Power Supply breaker tripped.MR · 2270032, 2268873
- ILINQ test message received from customer site.MR
- Left mouse button difficult to press due to faulty mouse.MR
- Defective Cable.MR
- MDS link failure due to SSM.MR · 2248816, 2248674
- Patient comfort sensor trip Due to Gradient Cooling Problem.MR · 2224667, 2224666
- Cradle will not move in or out due to SRI3.MR · 2254661, 2249129
- Coil validation error due to bent pins in the coil connector.MR · 2258107
- Use Model Type MR in eLicense for Discovery MR450 and Optima MR450W Systems.MR
- MRCustomerCall Image Quality Low Signal to Noise Ratio (SNR) Due To Coil Cable.MR · 2224589, 4062796
- Where are the MM3 Laptop Scripts or One Click Laptop Connection files Located?The MM3 Laptop Scripts or One Click Laptop Connection can be accessed from the Magnet Monitor 3 Deployment Site,wqr.Magnet…MR
- Head TR Driver faults Due to Loose Head Heliax Connection.MR · 2252305
- Will Not Scan with Gradient Errors due to Defective XRMW gradient coil.MR · 2267857
- How can the MAC address of the Magnet Monitor 3 be found.Log into the Magnet Monitor 3 to Determine the MAC Address,wqr.Magnet Monitor 3 1.62MR
- 2267889 The % axis XPS is reporting a High Voltage I-Bus Over-current Fault due to XGA.MR · 2267889, 2267835
- Scan pauses intermittently with errors logged due to SCP3 board.MR · 2249431, 116808
- Mouse Not Working Due To WIMMR · 2225385
- SNR low on Surface coils but Head coil Normal.MR
- SPT Fails Head Stability on isocenter slices Due to Scanning using the wrong phantom.MR
- An eLicense Option Key was Generated for the Wrong System ID, How Do We "Move It" to the Correct System ID?MR
- Unable to Boot Applications Software with Host Monitor Faults Due to Corrupt Image Database.MR · 200002352
- 2267857 gradient distortion fault has occurred on the % axis due to defective XGD amplifier.MR · 2218527, 2267857
- GP is reporting SGA Power Supply Power Off Fault due to SGA Power Supply.MR · 2244857, 2244587
- 2252305 TR Driver Fault Detected Open Circuit Source of Fault is Body TR Due to Hybrid Splitter.MR · 2252305, 2252357
- Banding in the reformatted images of a 2dtof runoff series can be caused by varying noise levels of the source axial images.MR
- ID184118. MR000002 PDS - MC Bias Alert - Channel Biasing Degradation Detected with Coil Due to Defective Cable Assembly.MR
- Table is making a grinding noise and will not move correctly from side to side.MR · 2224666
- TPS is not responding due to the ReceiverMR · 2267601
- Image partition on hard disk full.MR · 2218083, 700000
- How to check the gamma value currently running on an Ocatne-based system.MR
- SSM HVON and DRV FLT Rocker Switches Were In the "DIS" Position.Unable To Scan With Driver Module Errors.Set the SSM HVON and DRV FLT (MC,TR,DD) Rocker Switches to the "EN" Position wqr.Signa HDxT.225…MR · 2252289, 2249163
- What is the part number for the UTNS antenna?MR
- Series disappears after Completeing Edit Patient Data due to Low Maximum Images Configured in Edit Patient Data in Guided InstallMR
- Applications Software Will Not Boot with 2223639 Environmental Variable TPSHOST is not defined due to bad Fiber Optic CAN Assembly (CFB)MR · 2223639
- muticoil coil SNR low for cable broken.MR · 2224725
- Planned Maintenance PM Schedules Window Pops Up On The Screen Due to Too Much Time Since Last Planned MaintenanceMR · 2277504
- Blinking CPU lights on MV4000 computerMR
- What is the part number for the Bridge Height Gauge.MR
- Scanning intermittently interrupted with RF Hub errors due to the RF HUB CONTROL BD (RFCB).MR · 2224666, 2269910
- SupCent #2668249 The SHeM modem connection is intermittent, slow, poor, inconsistent.MR
- How to remotely find monitor model type configured in Octane-based systemsMR
- How to remotely find monitor refresh rate in hertz configured in Octane-based systems.MR
- CWA Browser Lists Exams from Last to First Instead of First to Last.MR
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2248847
- CWA Unable to Login to Boot Applications with username signa.MR
- How To Turn Off Or On Auto Network Transfers.MR
- SupCent #2668023 Coldhead Temp. (RUO) reading is low.MR
- Customer is unable to scan due to intermittent PDU PS1 48 V power supply failures.MR · 2269060, 19823
- Table raises very slow due to Hydraulic Pump Assembly.MR
- 2267863 The % axis XGA is reporting a I_Coil Wire Fault due to XGA amplifier.MR · 2267863, 2267778
Full cause & resolution for every GE MR issue
Unlock the complete cause analysis, step-by-step resolutions and attached service documents — re-authored, web-first, searchable.
Start free trial7-day free trial · no credit card required