GE Healthcare · MRSigna224485722445872244588225231851384
GP is reporting SGA Power Supply Power Off Fault due to SGA Power Supply.
Symptom
The driver module has detected a power supply fault
Error message
2244857 The GP is reporting SGA Power Supply Power Off Fault. Same as 2244587 and 2244588. 2244857 errorcode on Post 14M5 is the same error as 2244587 on 11X, G3 and 2244588 on 12X, E2, 14M4 (HDx, HDe).2244857 The GP is reporting SGA Power Supply Power Off Fault. 2252318 Exception Class The Driver Module Has Detected a Power Supply Fault Source of Fault is High Voltage Power Supply. Fri Apr 7 08:18:07 2006 Error: 2252318 Host: b5 Process: NSP File: SCP:DCB Line: 1355 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Vasc TOF Coil: HEAD Scan: 51384/3 The Driver Module Has Detected a Power Supply Fault. Source of Fault is High Voltage Power Supply. Actual Voltage = 10.0 Limit Voltage = 950.0->
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2334862-2 ACGD SGA PS ASM W/FRU PACKAGING See Long Description 2334862-2 Part Type: GP REPAIRABLES Part Weight: 2.18 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ACGD SGA PS ASM W/FRU PACKAGING FRU: Yes Status: Orderable This supply is for use with HFD, HFD-S, and ACGD Cabinets. ** WARNING - POSSIBLE PERSONAL INJURY. HEAVY OBJECT - THE POWER SUPPLY WITH CASE WEIGHS APPROXIMATELY 240 LBS (109 KG). Assistance to lift this product mechanical (Dollies) or Additional personnel] is required. 212002950 May 27, 2009
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.