GE Healthcare · MROptimaBrivo2227556226758733881226760122569252267519
TPS Reset Fails With Error 2267587 due to RRX Module
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2227556 *** Reset/Download TPS was not successful. *** 2227556 sdm sdm_main.c 320 *** Reset/Download TPS was not successful. *** 2267587 The RF Hub reports that the following RRX do not have an active fiber signal See in the long description. Tue Apr 13 10:45:30 2010 Error: 2267587 Host: nmr5 Process: diagCoord File: rfHub.cpp Line: 829 Task ID: 0x47d8d10 Time: 33881 Object: AGP Exception Class: Unknown Function: Software/Firmware/Config: N/A The RF Hub reports that the following RRX do not have an active fiber signal^A connection to the IRF3 or ERF boards. (RRX-1 RRX-2 ) Check the RRX, the IRF3, and the interconnecting fiber cables.-> 2267601 AGP forced TPS_reset to fail because AGP could not successfully calibrate the Exciters, Receivers, and Rf-Hub. Look for calibration related error messages in this log See Long Description 2267601 ERROR: EM_IRF3_CAL_FAILED AGP forced TPS_reset to fail because AGP could not successfully calibrate the Exciters, Receivers, and Rf-Hub. Look for calibration related error messages in this log. Extended Error : TPS_reset will fail if the AGP can not calibrate the TG tables for the exciters, the DC offset of the receivers, and the R1 gain of the RF
Applies to
- Models
- Optima, Brivo
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Component
- 5174169 HDv Remote Receiver Module 5174169 HDv Remote Receiver Module
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.