GE MR — field troubleshooting
9,114 field-service issues · page 24 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Using the HNS coil Scans Stop Intermittently With Error Code 2248008 "RFM EOS semaphore timeout error" due to IRF2 board.MR · 2248008
- CWA ID139134. All Coils are not being recognized by the System.MR · 2224857
- Planned Maintenance PM Schedules Window Pops Up On The Screen Due to Too Much Time Since Last Planned Maintenance.MR · 2218673
- The T/L Bridge is Broken Preventing the Latch from Locking onto the CTL Coil.MR
- Where Do I Find the Installation Instructions for the Ceiling Cable Curtain for the MR750 Magnet.MR
- Poor performance when using VCG or ECG Cardiac Gating Due to No layout available for ECG lead placementProper Patient Prep.MR
- Unable to Start the Service Desktop Browser Due To The SDM Process has Crashed and Cannot Execute most Service Tools.MR
- Design of System.MR
- Confirma MR Console Service Pack CD is not setup as FRU any longer at the GE end because this is delivered as part of the "CADstream Server Upgrade" from Confirma.MR · 5263496, 5159591
- Lower 10mm Of Image Has Very Low Signal On PURE Protocol Scan Due To Scan Area Outside Of Cal Area.MR · 2228303
- VCC measurement on front Panel of power supply in GIP out of Spec.MR · 2241608
- Unable to Scan with HD Lower leg Array Right Coil or Boot due to Error Code 2252303 Multicoil Bias Fault Short Circuit due to Coil's Preamp Box.MR · 2252357, 2224666
- Where do the Network Cables connect between the Ethernet Switch and the Sun ICN.MR
- Intermittent Corduroy Artifacts on HNS Head Coil only, due to HEAD NECK unit of HNS coil.MR
- CWA ID139398. Can Not Boot Application Software With VRE ErrorsMR · 2223859, 2223625
- Clarify gattention command doesn't Work on LINUX HP Host ComputerMR
- Multicoil Bias Fault Open Circuit on 7 Channel Breast Coil MRI Devices Due to Multicoil Assembly.MR · 2252301
- OrthoMRI What is the weight of the Escan magnet OrthoMRI Escan magnets weigh 1960 kg OrthoMRI Escan XQ OrthoMRI S/W Release 9.1BMR
- MRIQ White Lines in CEMRA Due to TRM Gradient Filter on the Pen PanelMR
- OrthoMRI Unable to acess CD drive, or Peripherals after Replacement Due to login Other than servMR
- The Main Disconnect PDU Power Breaker Tripped due to Loss of Incoming Power.MR
- MRIQ Images Show No Anatomy, Only Noise due to 1.5T Prima 9000 8-Channel Body Array.MR
- The MM3 Does Not Connect to Modem.MR
- Will Not Scan with Gradient Errors due to ACGD SGA Control Board.MR · 2245177, 43455
- CWA ID139457. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR · 200002352, 200002
- Medrad SHOPA3 coil fails to prescan after download of 11.0 M4 patch 14-PL.MR · 2252294
- CWA ID139460. Air Conditioning failure in the Computer room.MR · 2248606
- Exciter Calibration Errors And Power Monitor Trips Due to CERD Exciter.MR · 2234496, 2225664
- HP Computer Will Not Boot Applications Software due to AGP Board.MR · 2252112
- CWA ID139467. PM Assist reported a Failure with the 16ch Diagnostics and 21 days had expired.MR · 2218672
- When are the QMI / Technical Tele-Conference for HDxt, MR750, MR450, MR450w, and later MR Products.MR
- Gradient Diagnostic Failure due to STIF or SRF/TRF I/O Board Failure.MR · 2245309, 1627847
- Prescan fails or images are washed out / full of metal artifact.MR
- Blurry Knee Images after Upgrade to HDe 15.0 Software due to Timing Change of RF Excitation Pulses in FSE PSD in HDe 15.0 Software.MR · 13256879
- Signal Dropout, Ghosted Smeared Blurry Knee Images using STIR PSD after HDxT Upgrade due to a Software Problem in 15.0 Software.MR
- TCU powered off.MR
- Unable to scan with multi coil TR driver faults due to a failed preamp protection module.MR · 2225555
- CWA ID139593. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR · 2223849, 2223880
- Image Disk Space Is Low Due to Hard Drive.MR
- Question on ACR questionaire, For shimming, does GE use Spectro peak or phase difference.MR
- ermes Errors Due to Corrupt Error Message Database.MR
- Low SNR on all Channels of Standard Multicoil.MR
- Are the MOD Save Protocols saved from the GUI compatibles with the ones saved form the Service Desktop Browser.MR
- Cannot Scan Due to TR and Dynamic Disable Faults.MR · 2228537, 2218537
- CWA ID139880. Application Software does not complete the boot process with TPS Download failure.MR · 2223880
- RF calibration not in specification.MR
- Where is the SGI Octane Troubleshooting Flowchart ?MR
- 2256854 Process Prescan on board ICN1 appears to have failed Due to Large Debugging File.MR · 2256854
- FTP service wide open on scanner.MR
- The System is Missing the Functool Option.MR
- Around the time the HNS coil was configured, the cardiac coil with lava failed to download.MR · 2220029
- USA CTL 1.0 T SNR specifications on 9.1, Report Manager Does Not Contain Correct Passe/Failed limits for this CoilMR
- HP Linux Workstation fails to power due to a defective workstation.MR
- Multi coil Bias Fault errors on multiple coils due to plastic shaving in Multicoil port connector.MR · 2252301
- Compact PDU 80 Amp Main Circuit Breaker Will Not Reset in Auto Mode due to Logic Board C.MR
- RX Window Moved Because The Tech Was Wiping Off The Keyboard Keys.MR · 2254783
- Auto Subtract failed due to different between Phase FOVMR · 2218668
- CWA ID140016. Unable to Download or Reset The TPS MGD or ISE.MR · 2227556, 2249126
- SGA Power Supply Over Voltage Fault Due to SGA Power Supply.MR · 2244843
- USB Service Key Not Working.MR
- MRIQ Noise Band Due to PURE Image Enhancement option.MR
- HDx and HDxt Upgrade Documents Are Not Described Or Listed As System Installations.MR
- Documentation is Not Clear.MR · 60761
- CWA ID140116. Will Not Scan with Gradient Errors.MR · 2244871
- The PDU is in Stop Mode Due to Phoenix PDU control board.MR · 2248602
- Unable to Start IVI.MR
- Unable to emulate PDU/Emergency stop circuitry.MR
- EMO Reset button not responding because of a loose cable between the SCIM and the WIM.MR · 2224666
- Unable to download propeller due to a corrupt protocol.MR · 3000004
- Fails TPS Reset when booting up to Applications or when Resetting TPS due to UPM NB AMP IF Board in ASC Chassis.MR · 2252233, 2262850
- Equipment Room temperature exceeds GE specification window of 59-89.6°F (15-32 °C).MR
- CWA ID140312. Auto Prescan Failure.MR · 2224583
- HFO or MFO Swing Table Stuck in the Down Position.MR
- Unexpected Table Motion Errors Due To Table Out Of Adjustment.MR · 2224864
- OrthoMRI MTU packet size set up on customer's VPN too small OrthoMRI intermittent errors when sending images to the remote station OrthoMRI Adjusting the MTU Size for the Network Card on the Modality…MR
- OrthoMRI CPU battery failure.MR
- Ghosted Images on All Coils, All PSDs.MR
- Unable to mount IRIX 6.5 CD labeled “Boot/Update” during software Load From Cold Procedure.MR
- The PDU is in Stop Mode Due to Phoenix PDU control board.MR
- CWA ID140392. Can Not Boot Application Software With VRE Errors.MR · 2223859, 2223883