GE MR — field troubleshooting
9,114 field-service issues · page 20 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- MOD Will Not Insert or Load into the MOD Drive Due to the MOD Drive.MR
- Unable to Start Multicoil Receive Chain Tool due to Error Another Instance of Multi Coil Receive Chain is already running .. due to Someone Already Started Multicoil Receive Chain Tool in Current Boot…MR
- FMI 60746 Upgrade from Signa HD_M5 to Signa HD_M5A Must Be Installed Prior to FMI 60752 Upgrade. 3T Excite HD 12.0.MR · 60752, 60746
- How Do You Find Host ID for eLicense.There are Two Ways to Find Host ID.Excite.11.0MR
- Customer wants to convert DAT Tape Archive to something compatible with Excite.MR
- 133485 Unable to Scan with SSM HV Power Supply Low Errors.MR · 2249147, 2248599
- What is the model type to be used for Insite CheckoutMR
- Unable to scan with Power Monitor Faults on Head Coil due to Center Frequency Was Off By 400 Hz.MR · 2254782
- Cannot add new coil Invivo 7 channel Breast coil due to Failure to Save Changes before exiting Config File Manager.MR
- Asset Scan Wont Run Due To Different Scan Range Than Asset Cal Scan.MR · 2218528, 2227990
- MRCustomerCall Image Quality DWI Motion Pixel Voids (wormhole artifacts) due to patient motion.MR
- Wrong date causes PM Pop Up Message to Remain Posted.MR
- Will Not Scan with Gradient Errors.MR · 2240243
- CWA ID133585. Application Software does not complete the boot process with TPS Download failure.MR · 2223849, 2252112
- Cannot Network to Remote Host Due to AE Title Does Not Match Uppercase or Lowercase of Actual Destination.MR · 11010
- What is the TCU2 Temperature Controller Unit II Setup and Calibration.MR
- SCP2 Board may be incorrectly reported in the HART Log as an SCP Board.MR
- PDU was in stop mode.MR · 2248662, 2252318
- Unable to Boot Due to System Cabinet 8-Port Ethernet Switch Communication.MR · 2223849, 200002352
- Cannot Open the Network/archive Queue because the Remote Host is configured for Archive Node Auto Detect which can't be reachedMR
- Twin speed Main Disconnect Panel does not turn on due to lack of 12 DC from Charging Circuit.MR
- CWA ID133813. Protocol Never Downloads Due to a Corrupt Series Download.MR
- CWA ID133818. Corrupt Image Database.MR · 2218062
- 2248261Receiver Channel Map doesn't match the number of Receivers in Scan Setup Packet due to mcChannelSelect value of 127.MR · 2248261
- Corrupt Image Database.MR
- How to interpret the SdCRHosts file.MR
- RF calibration not in specification.MR · 2224589, 4062796
- PDU was in stop modeMR · 2244857, 2244587
- What is the Part Number for the Retaining Clip used on the Lateral Crank Handle on the HFO/MFO Swing Table.MR
- Cannot Save Protocols to MOD Due to Corrupt Protocol.MR · 2219999
- Table Caster Will Not Swivel Due to Caster Pin that Moves Locking Arm Bent and Falling OffMR
- OrthoMRI How to Turn Off Auto Send OrthoMRI Steps to Turn off Auto Send Orthopedics E-Scan Orthopedics E-Scan (win) XQ OrthoMRI 3.1BMR
- CWA ID133982. Some or All Images in the Last Scan Did Not Reconstruct.MR · 2218077
- PDU was in stop mode.MR · 2254352, 2244857
- PACS not configured correctly.MR
- How do I reinstall mini viewer.MR
- The O2 Sensor is Faulty.MR
- Unable to Create or Edit Protocols Due to setupProtocols Script Was Executed From root Login.MR · 2219663
- Cannot Establish Landmark Due to System Needs Longitudinal Drive Calibration.MR
- Cannot Archive Due to Corrupt MOD media disk.MR · 1213501, 10102
- report card filming setup does not stay after rebootMR
- Unable To Login As Root Due To Changed Password.MR
- FE needs to order the HFO "T" fitting for the bypass unitMR
- Can Customer Save Raw Data Files to CDR or DVD Media using the System's CD/DVD Drive.MR
- Colapsed Image.MR · 2241520
- Applications Will Not Boot with SRI SPI Communication Error Due to FO Repeater Board at PP.MR · 2224829, 2224839
- What Level Should the Computer Equipment Scan and Operator Room Temperature and Humidity Be Set.MR
- Unable to Perform Grafidy3 with New Grafidy3 6-Coil Kits Received March and April 2009 due to 1.5T Grafidy3 6-Coil Kit 5135527 has Incorrectly Programmed Coilid Code.MR
- Cannot Boot Applications Due to Host Monitor Timeout Error and IRF BoardMR · 2249410, 23639
- Pressure Heater controller software is stuck.MR
- How to Determine the Host ID on the HP8000 Computer.MR
- Diffusion does not work on NV Array coil on HFO3 getting "coil not compatible" message.MR
- How do you identify which CPU is on a Profile or Contour UNIX system?MR
- The Volume Level of the Intercom in the bore is Much Lower than the Level in the Patient's Head Set using the Magnacoustics Sound System due to the Integrated Magnacoustics Sound System.Excite HDe 14.…MR
- Defective Scan Monitor.MR
- Can Not Scan With An instruction on waveform generator SSP executes beyond the act_tr.MR · 2227063, 38638
- HP 9300 Rebooting Itself during booting.MR
- Erroneous emergency stop message generated by Auxiliary Board.MR · 2267825
- The helium level is dropping greater than 5% over a 30 day period due to a possible helium leak.MAC00005 Proactive Magnet Performance Issue.Low level Helium Loss > 5% in 30 days.MR
- Corrupt Image Database.MR · 16003
- Coil not plugged in properly.MR · 2252301, 2252293
- Defective GP Module.MR · 2241545
- Patient Comfort Sensor Trips Due To Cooling Water Temperature Too High.MR
- Unable to Scan with Not enough TPS memory available Errors. remove ZIP512. 3.0T Signa HDxT 15.0. 2227994 The memory or other resources may be insufficientMR · 2227994
- Fails TPS Reset when booting up to Applications or when Resetting TPS Due to failed Scan Room Power Supply.MR · 2270016, 2252239
- RF Amp Not Ready with Error Codes 2254347, 2254342, and 2254352 due to SRFD2 RF Amplifier.MR · 2254347, 2254352
- Image Ghost Due to Patient Respiratory Motion.MR
- Broken handle on anterior section of USAI 8 Channel body array.MR
- Details on Customer Letter entitled Table lowering hazard on GE Signa OpenSpeed and Ovation MR Scanners.MR
- Unable to connect to InSite 2 via GE VPN Tunnel.Unable to connect to InSite 2 thru GE VPN Tunnel.Properly Configure the InSite 2 device to use the GE VPN Tunnel.Magnet Monitor 3.InSite Running, Can't…MR · 5155500
- Applications will not Initialize with PM Due Pop Up Message Due to PM Not Scheduled.MR · 2218670
- T/R Driver Faults Due To SSM.MR · 2225519
- What is the MR Signa Applications Support phone number.MR
- PM check does not complete.MR
- 2247373 UTNS/Receiver Gain diagnostic failed.MR · 2247373
- Will Not Scan With Gradient Errors Due To GRAM Module.MR · 2238663, 2238645
- CoilID Validation Fails Due to Wrong Coil ConnectorMR · 2258106
- Table Will Not Turn on the Floor Due to Table wheel.MR
- MRSPT Head GRE Stability Fails Due to GP3.MR · 2245097
- Coil ID LED is off when 3T NV array coil is connected due to defective Coil cable.MR