133485 Unable to Scan with SSM HV Power Supply Low Errors.
Symptom
Unable to Scan with SSM HV Power Supply Low Errors. See long description. New install. Unable to do first scan, get one pulse in prescan and then get a "SSM HV power supply low" and an "inductive or direct drive fault. Both faults state possible shorted load. The FE did a diode check on the BCD1, BCD2, and DD drive lines at the rear of the SSM, and read diode on all. FE powered off the SSM and then powered back on and measured OL on the HV test point on the CPFD, and then after about 25 seconds the HV went to 6-7 volts and HVPS fault led lit on the SSM, this happens with or without the BCD1, BCD2, and DD cables connected. This was very repeatable. FE got into the SSM and found the HV would stay up if the HV line to the CPD was disconnected at J5 (red cable) and JP2 in on the HV board and monitoring at TP7 & TP4 on the HV board. Also found a chip on the SSM which had a hole burned through it (don't know the location of this chip). With all of this we have concluded that the CPD is likely the problem. The SSM is the FRU on Excite systems. FE to order the SSM.
Error message
2249147 High Voltage Power Supply Low. Also may be a shorted load on dynamic disable or direct drive circuits. Tue Mar 30 13:50:47 2004 Error: 2249147 Host: CCRC Process: NSP File: SCP:../TrDriverMdsHWO.cpp Line: 1255 SSM fault.^A High voltage power supply low. Also may be a shorted load on dynamic disable or direct drive circuits. 2248599 A T/R or dynamic disable fault occurred. 2248599 IC_OPEN_SG NSP APS:aps_cf 220 A T/R or dynamic disable fault occurred.
Applies to
- Models
- Ovation, Excite, Signa
- Product
- Ovation with EXCITE
- Software
- OVATION5 Applies to Ovation5 (Excite) only. Ovation5 is 12.x platform software, not OvationHD.
- Component
- 2160200-45 SSM assy for Ovation/OpenSpeed
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.