GE MR — field troubleshooting
9,114 field-service issues · page 19 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- 2252304 Multi Coil Bias Fault Due to Driver Module for Excite.MR · 2252304, 50334
- Table Longitudinal Drive Problems Due to Gear Reducer 40 to 1 Gear Box.MR
- Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.Unable to Scan with RF Air Temperature FaultsMR · 2261733, 2268905
- Lytron Chiller Replaces Neslab, Information and Part Numbers Needed.MR
- CWA ID131578. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR · 2223621
- TRM Shim Cable Termination Connector is missing.MR
- Customer has a Research Agreement with GE and Needs Support on Research PSDs.MR
- How to Determine / Identify Magnet Serial Number.Magnet serial number can be found in the MRconfig.cfg file.Excite.11.1MR
- FATSAT on Ovation doesn't work properly.MR
- MKS 3.0T 35 KW RF Amplifier will not power up Due to blown line fuses.MR · 2261230, 2254342
- Magnet Monitor devices Alarming for Coldhead Temperatures because the Checkout was not completed properly.SIV ALARM 1ST STAGE SHIELD TEMP HIGH.Magnet Monitor Devices Alarming For Coldhead Temperatures…MR
- Compressor shuts down within 30 minutes of resetting Due to Water cooling failure.CXI2 ALARM I2 COMP OFF.The water chiller that supplies water cooling to the compressor will need maintenance.Magnet Mo…MR
- OrthoMRI What is the field strength of the magnet?MR
- Open or disconnected cable or bad pressure transducer.SIIII2 ALARM I2 - HEPRESSURE CABLE OPEN.Follow Magnet Monitor 3 Alarm handling procedures and verify that the Questra and Drag-on pages are updati…MR
- CWA ID131775. Octane Computer Crashed.MR · 2217489, 2218077
- Patient Comfort Module Fan Motor is Producing a High Pitch Squeal.MR
- CWA ID131889. System still Allows Protocol Changes Without Password After Lock Protocol was Set In GUI.MR
- Found Medcam board is not responding and fails TPS diagnostics.MR · 2223847, 2223621
- No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.MR · 2248602
- CWA ID131919. Applications Software Will Not Boot.MR · 2223621
- Intermittently unable to download or scan the Propeller PSD Due to the Eight Port Ethernet Switch.MR · 2256458
- Wrong type of data on the accession number field.MR · 11046
- CWA ID131935. Unable to Create or Edit Protocols Due to setupProtocols Script Was Executed From root Login.MR · 2219999, 2219662
- The BIT 3 FIBER OPTIC INTERFACE Module in the Octane Computer Cabinet Failed.MR · 2224360, 2224330
- Will Not Scan with Gradient Errors Due to the GSC Twin Gradient Switch Module Box.MR · 2244655, 2244649
- Unable to Start Clariview.MR
- Octane Was Powered On Before MOD Drive Powered OnMR · 10191
- Can Not Boot Applications Software Due To ICN.MR · 2223883, 2223859
- Infiniband cables on left port on ICNs port 2.MR · 2249420, 106634
- Current Distortion Faults Due to HFA CONTROL BOARD ASSEMBLY.MR · 2244851, 2244577
- Swapped labeling of J11 and J12 connectors of fiber optic cable run causing the installer to cross the connections going from the pen-panel to the SRI.MR
- Global Order Number GON Needed for eLicense.MR
- Cannot Archive Due to Corrupt MOD medium disk.MR · 10102
- Monarch Error Due to Infiniband cables on left port on ICNs port 2.MR · 2249432, 2249420
- How To Find Directories Consuming the Most File Space. du and sort Command To Find Directories In Descending Order of Largest File Space ConsumedMR
- Unable to boot due to hard drive.MR · 200002357, 2246068
- Where is MCQA Test Data Located on System.MR
- Where is the Quench Report found.MR
- Install in Spec IIS Fails with Error Missing Probe P Calibrations Due to breastsvq Option.MR
- Reasons Why the IBIS Web Portal is Not Updated After a Sweep.MR
- CWA ID132466. How to Remotely Check Operator Settings For Remote Host Parameters.MR
- CWA ID132493. Customer Restored Power to and Rebooted Router.MR · 2219945, 200002356
- Compressor Shut Off Due to Chiller Issue. lcc300i2 alarm I2 - Comp Temp Limit 123.MR
- CWA ID132592 Banding and Signal Drop in CUBE is due to Phase Correction Choosing Echoes of Lower SNR in Cube.MR
- The SWIFT Application Button is Missing From the Browser due to Someone at the Site Accidently Deleted the Button from the Browser in Services -- Application Management.MR
- CWA ID132608. Can Not Scan.MR · 2219549
- Compressor Not Functioning Due to insufficient power to the compressor. siiii2 alarm I2 HePressure Limit.MR
- How do You Display Ethernet Card Settings?MR
- Customer's chiller is operating outside of specifications.MR
- Center Frequency was off.MR · 2224567
- CWA ID132703 Artifacts in SWAN in Sagittal Plane.MR · 13250234
- PDU was in stop mode.MR · 2218537
- Unable to film due to network Hub Turned Off.MR · 14145
- CWA ID132728. How To Add Network Workstation Host.MR
- How to Get Every Protocol Series Description From Any MR System to Load Into PACs For Identification.MR
- How to Determine Advanced or Restricted Service Key Expiration Date?MR
- CWA ID132760. Application Software Is Slow Due To dcserver PID's Taking Up CPU Time.MR
- Profile cannot find part number for Keyboard Adaptor bd. not listed in Service Docs.MR
- Low Vessel Pressure Alarms due to Post Magnet Service Alarm Handling Procedure Failure.lcc300 alarm He Vessel Pressure Low.Place a hold off on the He Vessel Pressure alarm to allow time for LOW magnet…MR
- Details on Customer Letter entitled Table lowering hazard on GE Signa OpenSpeed and Ovation MR Scanners.MR
- CWA ID132877. Unable to scan.MR · 2218527
- CWA ID132916. Table dock hook is stuck in down position, too low to hook onto the ring of the dock assembly.MR
- CWA ID132917. Due To Coil Not Being Seated Properly.MR · 2224725
- TPS Reset Failure with Processor Exception Frame Error Due to Dual PPC Module.MR · 2227556
- Will Not Scan with No Respiratory Trigger Gating Signal Found Due to SRF TRF Board.MR · 2227337
- CWA ID133135. Application Software does not complete the boot process with TPS Download failure Due to Idle Overnight With Power On.MR · 2223817, 2252106
- The Medrad HD NV Coil may demonstrate intermittent Open Circuit Driver faults during scanning.MR · 2252301
- TCU powered off.MR
- Lines superimposed on the LCD Monitor.MR
- CWA ID133181. Corrupt Image Database.MR · 2218082, 2218527
- Compressor Not Functioning Due to insufficient power to the compressor.siiii2 alarm I2 Comp Off.Reset the Shield Cooler or Cold head Compressor.Magnet S3.siiii2 alarm I2 Comp Off.MM3 1.56MR
- Carriage LPCA Hook will not latch to Cradle Due to Carriage Actuator or Plunger adjustment.MR
- What is the Weight of the SI Magnet.MR
- Equipment Room Humidity Has Exceeded the Maximum Lower Limits Due to Sites HVAC.MR · 2269048
- Unable to scan with Power Monitor Faults.MR · 2254782, 13444
- Defective LCD monitor.MR
- Save State does not transfer all changes over the networkMR
- How to figure out MGD AP types.MR
- How To Turn Off Data Mining.MR · 2218088
- Where is MCQA Test Data Located on System.MR