Fails TPS Reset when booting up to Applications or when Resetting TPS Due to failed Scan Room Power Supply.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2270016 ADS1 VRF did not receive correct device ID from RRX module in scan room. RRX does not exist or is not connected to VRF. The VRF is located at ICN1(ICN2), Fri Feb 27 07:06:54 2009 Error: 2270016 Host: mr1 heri Process: LxMxConsumer File: VrfTrace.cpp Line: 80 Server Name: ADS1 VRF did not receive correct device ID from RRX module in scan room. RRX does not exist or is not connected to VRF. The VRF is located at ICN1(ICN2), if ADS(ADS1) reports this error. VRF ID: 0 Device ID: 2- 2252239 Startup Timeout was detected on the RF Hub. Fri Feb 27 07:06:41 2009 Error: 2252239 Host: mr1 heri Process: NSP File: SCP:CanAutoConfig Line: 3377 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 Startup Timeout was detected on the RF Hub.- 2269061 The 1-Wire Network detected that either the XGD Ethernet or DVMR Fiber Optic Links ar e down Fri Feb 27 07:08:59 2009 Error: 2269061 Host: mr1 heri Process: diagCoord File: oneWire.c Line: 1157 Task ID: 0x6db4440 Time: 25258 Object: AGP Exception Class: Notification Function: Software/Firmware/Config: N/A The 1-Wire Network detected that either the XGD Ethernet or DVMR Fiber O
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Component
- 5231801-3 Scan Room Power Supply 16 ch and 32 ch 5231801-3 Scan Room Power Supply, 16 ch and 32 ch
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.