GE Healthcare · MRSignaExciteDiscoveryOptima22238492252112222385222238802223817
CWA ID133585. Application Software does not complete the boot process with TPS Download failure.
Symptom
Application Software does not complete the boot process with TPS Download failure
Error message
2223849 SCP EPROM power-up boot failed (See attachment for extended error message) 2223849 rmny NSP TardisReset.cc 1841 Exception Class: Unknown Function: Host: NSP SCP EPROM power-up boot failed. Communication Timed-out from SCP board. Verify that MCP820 boards are installed and seated properly for APS and AGP.-> 2252112 Board SCP is in invalid power up state 2 See Long Description Verify ENV parameters and retry power up. Extended Error: The board may be in one of the following states: 0 - No response, 1 - OS Loaded, 2 - PPC Bug, 3 - PPC Diag, 4 - OS not loaded If the error message states that the board is in state 4, then the OS load was stopped. This may happen if characters are detected on the serial cable. In order to eliminate this problem, disconnect the serial cable from AGP/COM1 Connector or SCP/Console Connector and reboot the board. If the error message states that the board is in state 2 or 3, then run the Motorola Board Level Diagnostics to verify the board is OK. If the BLD passes but this message appears during TPS reset then it is highly probable that the boards are not being reset by STIF connection. You can verify if the boards are not being reset by STIF connec
Applies to
- Models
- Signa, Excite, Discovery, Optima
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.