GE MR — field troubleshooting
9,114 field-service issues · page 12 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Corrupt Image Database.MR · 2218085, 2224340
- Open or disconnected cable or bad pressure transducer.MR
- Gibbs Ringing Artifact Due to Incomplete Digitization of the Echo.MR
- The compressor is not charged properly. lcc300i2 alarm I2 HePressure Limit.MR
- Incomplete Documentation.MR · 13225213, 580707
- SGA Power Supply Over Voltage Fault Due to SGA Power Supply.MR · 2244592
- OrthoMRI TPM module needs to be reset.MR
- OrthoMRI Corroded/Dirty network printer cable connector OrthoMRI Open association error when sending 3 on 1 images to the printer OrthoMRI Cleaned network printer cable connectors OrthoMRI Escan XQ Or…MR
- OrthoMRI The customer ran the scout with "Other" selected as the anatomy OrthoMRI No customer protocols in the list after scout OrthoMRI Reran the scout with correct anatomy then the protocols were in…MR
- OrthoMRI Incorrect magnet temperatureMR
- OrthoMRI Probable loss of power during hurricane, need to isolate the MRI system from electrical grid.MR
- OrthoMRI Blown fuse in the SRFA module OrthoMRI Unable to scan due to RFA failure Replaced SRFA fuse OrthoMRI Escan XQ OrthoMRI SRFA OFF Direct power supply failure to the RF amplifierMR
- OrthoMRI There is metal attached to the patient's clothes which caused the signal loss OrthoMRI No signal on the top of the real time images OrthoMRI Removed the metal object from the patient's clothe…MR
- No Scan Time or Respiratory Signal Display Seen on The PC Display Monitor.MR · 2240400
- Unable to scan with multicoil TR driver faults due to a failed preamp protection module.MR · 2225558
- Cannot Boot Applications with Host Monitor Timeout Error due to YP(NIS) Service was turned "On" in Network Configuration in Guided Install.MR · 2249372, 1706269
- DRF Over Range Errors Due to Gradient Power Supply.MR · 2248108
- 2225740 Analogic RF Amplifier 1 Power Loss Fault due to RFI.MR · 2225740
- Cannot print after upgrade from 11.0 to 11.1 FMI 60747 Due to Printer Not Configured.MR
- MRIQ Signal Loss on Multiple Coils due to bent pins in Legacy Connector.MR
- Cable from Instrumentation Box Assembly to LCC magnet turret not seated properly. lcci2 alarm I2 Heater stuck on 100.MR
- Octane Computer Hangs With Errors.MR · 195805184
- CoilID Fails Unless Cradle is at Home Position due to Intermittent Cable in Rear Pedestal Cable and Track Assembly.MR · 2262134
- The systemhealth files on the ASC Drag-On Health Page Viewer have been compressed to save server space and decrease download time.MR
- Low water flow alarm due to Water Flow and Temperature Assembly Failure.LCCI2 ALARM I2 WATERFLOW LOW.Rebuild flow sensor per Service Note 67097.Magnet Monitor 3.LCCI2 ALARM I2 WATERFLOW LOW.MR
- PC Computer won't Boot due to failed power supply in PC.MR
- MRCustomerCall Dark Signal Void or Shading in Center of Anatomy Due to Bad Prescan MRIQ100002.MR
- Equipment Room temperature exceeds GE specification window of 59-89.6°F (15-32 °C).MR
- CWA ID12100. Unable to send images to PACS.MR · 11057, 32736
- 2234203 QIN arbitration bus error Due to UCERD Digital board.MR · 2233396, 2234203
- Computer Does Not Recognize The MOD Drive and scsistat Does Not List the MOD Drive.MR · 2246014, 1113497804
- How To Prune Profile System Log File When It Gets Too LargeMR
- CWA ID121069. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR · 2257017
- High Transmit Gain Is Due To Large Patient Over 250lbs.MR · 2248825
- Head and Body SPT Stability Fail Due to Wrong Grafidy Values.MR · 2225146, 2234211
- Intermittent Signal Brightness changes from image to image Due to the 8 Channel NV Array CoilMR
- Unusualy High TG During LV Shim Due to Body Coil.MR
- 2248121 APS Send DRF Error Due to DRF.MR · 2248121, 2248131
- Will Not Scan with Gradient Clock Stop Errors Due to STIF Board.MR · 2250109
- Unable to Network to PACS Due to 8 Port Ethernet Switch Hub.MR · 11029
- PPC Module failed on AP board.MR · 2224666, 2228718
- Unable to Boot Applications Software with Host Monitor Faults Due to Corrupt Image Database.MR · 200002372, 200002352
- MOD Drive will Not Insert or Load MOD.MR · 10286
- PPC Module failed on AP board.MR · 2224666, 2228010
- Unable to Run EPT with error Unable to write EPT header file due to Corrupt Software.MR
- Service Key Unrecognized Due to Vendor Mislabeling LPT1 and LPT2 Connectors on Operator Workspace PC.MR · 2284297, 13186389
- New Operator Workspace PC FRU is Physically Different From Original Part.MR · 2284297
- The systemhealth files on the ASC Drag-On Health Page Viewer have been compressed to save server space and decrease download time.MR
- Unable to Run ECMT2 (Eddy Current Measurement Tool 2) due to ECMT2 Tool Hardware Kit.MR
- Signal Too Small to Process Due to Twin Gradient Switch Box.MR · 2224580
- SCIC and IMAGE FILTER Will Not Work Prospectively.MR · 2220019
- Set Jumpers on MOD Drive Incorrectly During FMI 60754 Installation.MR · 10102
- System Forgets DASM Setup on Every System Reboot Since 11.1 Software Upgrade FMI 60747 Installation due to Software Bug in 11.1 M4 Software.MR
- CWA ID121286. MRIQ Multiple System Cross talk Artifact Theory.MR
- Driver Module Errors Due to Driver Module.MR · 2252304, 50334
- Can SPT in PM mode be run to satisfy the SPT requirement for generating an install_in_spec key.MR
- CWA ID121303. Loss of Signal or Shading in Spine Images due to center frequency is off by 2KHz.MR
- Banana plug on the Head T/R switch has bent/broken fingers causing coil to disconnect.MR · 2224580, 2224725
- How to Find SCSI Devices on Ovation with Linux.MR
- CWA ID121384. Mouse Cursor Movement Erratic Due to Mouse.MR
- Slow and intermittent erratic Table movement Due to New style cradles and wheels are not strong enough to handle weight.MR
- Cradle will not advance to scan due to contrast media on bridge under cradle.MR · 2224842
- CWA ID121528. Applications will not Initialize with PM Due Pop Up Message Due to PM Not Scheduled.MR
- Shaded Area Seen Only Using FIESTA PSD.MR
- CWA ID121558. Corrupt Image Database.MR
- Customer Wants to Know if an Exam They Removed can be Restored.MR
- CWA ID121605. Fails to Scan with TORSO Coil.MR · 2225553
- MRIQ No signal on Medical Advances Knee coil due to blown fuse in Quick Disconnect box.MR
- Unable to Find Details on Cable Run 1381 Power Cable to GOC Shipped After July 1, 2008.MR · 5166001, 5155500
- Error Messages for MFO Systems refer to Rear and Front of BRM, which doesn't exist on Ovation.MR · 2249160, 2249157
- Peripheral Gating not functioning due to poor fiber optic connections at the PAC.MR
- RRF Errors Due to IRF Board.MR · 2253574, 2248160
- Internal DVD Drive Inside xw8400 PC Not Reading or Writing on Discovery MR750.MR
- Plasma and Image Monitor Blank Due to Genesis Console Power Supply.MR
- Discovery MR750 Does Not Support DASM.MR
- Troubleshooting Tips for DVMR Table Elevation Problems.MR
- Baldor Dock Motor does Not Function on Non Shielded Magnets.MR
- Unable to Align Dock on Forward Production Magnet During Installation So That Table is Properly Aligned with Bridge.MR
- CWA ID121756. Unable to Scan with Message The IRF3 is not ready.MR · 2248602, 2267798
- Is it Possible to Jumper the Emergency Stop Temporarily at the PDU for Troubleshooting Purposes?MR