GE MR — field troubleshooting
9,114 field-service issues · page 11 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Table Can Be Moved by Hand in Lateral Direction without Enabling Latch Switch.MR
- MFO table will not lower due to home flag position that was altered by a large patient when getting off the table.MR
- Do the DRF1 or DRF2 (Digital Receive Filter) Boards Require Switch or Jumper Settings Before Installation.MR
- OrthoMRI Radiologist changed the remote host IP address OrthoMRI Modifying Remote Host Configuration OrthoMRI Procedure to Modify Remote Host Configuration Orthopedics E-Scan (Win) XQ.MR
- Corrupt Image DatabaseMR · 2224382, 2218062
- Software is Corrupt.MR · 2223817
- Unable to archive Due to svst File.MR · 10033
- Corrupt Image DatabaseMR
- Low Vessel Pressure Alarms due to Post Magnet Service Alarm Handling Procedure Failure. lcci2 alarm I2 HePressure Low.MR
- Monitor is gray due to the Color Palette in the Host.cfg system tab is changed to gray.MR
- Can Not Restore Exam Images From MOD Due to Corrupt Image DB.MR
- CWA ID118772. Unable to Scan with PDU ErrorMR · 2218537, 2224666
- CWA ID118802. Cycle Power To The System Cabinet And Reset TPS.MR · 2233312
- SRF and TRF Power Faults Due to MGD Power Supplies.MR · 2257210, 2252720
- Fat Sat Not Uniform, or No Fat Sat At All, Due to Center Frequency Not Set At Optimum Value.MR
- Cannot Boot to Login Prompt During LFC of FMI 60748 Due to Corrupt CD.MR · 60748
- The customer wants to change the host passwords.MR
- MRIQ Head Flair Ghosting Due to SGA Control Board.MR
- The Magnet Monitor 3 Alarm data is delivered seperately from the parameter data.MR
- Clarify how to set up an LX system (9.x/10.x) for a network with multiple routers or gateways.MR
- Can Customer Edit the Date and/or Time That Scan Was Done.MR
- What is the ampere rating on the Sumitomo Compressor incoming fuses, there is no label.MR
- Will Not Scan with Gradient Errors.MR · 2241550, 2241518
- DQA Slice Location test is sensitive to Phantom positioning.MR
- CWA ID119111. GPM PS breaker off on front of Gradient cabinet.MR · 2241508, 2225703
- Magnet Monitor 3 Helium Level Alarm Low Limit is determined by Florence Magnet Engineering.MR
- HDx TPS Reset Failure Due to a Image Compute Node ICN.MR · 2223878, 001631
- Can Exam Images Saved to MOD or CD From One Scanner Be Restored to a Different Software Revision GE Scanner.MR
- High Vessel pressure Due to the chilled water source NOT meeting Coldhead Compressor cooling requirements.MR
- Patient comfort sensor trip Due to Gradient Cooling Problem.MR · 2224667
- the u-shaped arm of the breast biopsy device that compresses the breasts is cracked.MR
- IBIS System not recognizing SPT as a full pass.MR
- Frequent Error Messages Regarding Unexpected Table Motion.MR · 2224842
- TPS Reset Fails Due to RF NB AMP I/O.MR · 2261239
- Low Voltage on the High Voltage SSM Supply.MR · 2225540, 2225526
- CWA ID119427. Will Not Scan With RF Errors.MR · 2254278
- CWA ID119430. The head coil was not placed at the end of the cradle in its base slot.MR
- 2255087 Shim Supply ADC Gain Error due to failed Z2 Supply.MR · 2255087, 2255085
- lcci2 alarm I2 ShieldTemp Low.MR
- Helium Vessel Pressure Low over long periods of time on BoilOff Magnets can be due to bad flow balancing. cxi2 alarm I2 HePressure Low.MR
- Table Longitudinal Drive Problems Due to Gear Reducer 40 to 1 Gear Box.MR
- Cannot scan Diffusion with Ref errors.MR · 2218527
- Defective Water Temperature sensor producing inaccurate temperature reading.MR
- Vessel pressure is low due to a magnet quench.MR
- Images are grainy due to poor seating of coil connector caused by loose banana plug.MR
- MAGNETS Shim Lead pins leak, low magnet pressure.MR · 003454
- FEs are uncertain how to address magnets delivered that are configured for Air Shipment.MR
- Magnet Monitor 3 DHCP Connection loss caused by Network Switch.MR
- How to install a DASM.MR
- High Speed Stability 3.0T (HSS) Procedure Lists a Non-3.0T HSS Kit 46-320383G1 as Tools and Test Equipment.MR · 5133330, 13222921
- Magnet Monitor 3 Does Not Regulate Magnet Vessel Pressure After SHeM Replacement.MR
- Will Not Scan With RF Errors due to SRFD2.MR · 2222733, 2225470
- Unable to Select Gradient Mode in the 3.0T HSS procedure (High Speed Stability 3.0T).MR · 13222921, 5133330
- The compressor is not charged properly.MR
- No Documented Procedure to Perform checkINFO on HFO4 Systems. checkINFO Procedure for HFO4 Systems.MR · 13214413
- The music system microphone was not turned on from the stereo control box.MR
- Unable to Run AP Component and Memory Diag due to Error in Software InstructionsMR
- Exam is not in the Browser because it was deleted.MR
- Cracked large shoulder coil.MR
- Is it necessary to power down a Magnet Monitor 3 prior to a scheduled power outage.MR
- Low Hydraulic Fluid Level.MR
- Wave Monitor is displaying no signal message box after HP replacement.MR
- HP will not boot to DVD during a software load.MR
- Fast Out Button Moves Table Briefly then Stops Due to SRI3.MR
- PPBM voltage has exceeded the allowed range Due to 8645 Output Shelf.MR · 2238549
- The Guided Install Configuration Language Was Improperly Set.MR · 13214745
- What is the Function of MAGNET MONITOR OUT on the HDe Cabinet Monitor Module.MR · 5144304
- How Can I Track Cabinet Monitor Functions Over Time.MR
- Will Not Scan With Patient Comfort Sensor Trip Due to Scan room temperature was warmer than normal.MR · 2248652, 2224666
- What is the Part Number for the Respiratory Bellows Assembly.MR
- MOD drive will not recognize media.MR · 10191, 10033
- Magnet Monitor 3 Helium Level Alarm Low Limit is determined by Florence Magnet Engineering. hfo_orgi2 alarm I2 HeLevelTop Low.MR
- ICW Reports that MNS Calibrations were Not Done on a System Without MNS Due to Upgrade Order Information Incorrectly had MNS Software Option.MR
- 2258107 Coil Check Host coil validation error Body Transmit Enable mismatch detected Due to large cable track and harness.MR · 2258107
- 16 Channel Switch Diagnostics Fail Due to 16 Channel Switch.MR · 2247386, 18571
- Magnet Monitor 3 U90 chip on the Water Sensor Circuits is failing.MR
- CWA ID120252. Host Computer Hard Disk Swap Space Too Low Due to Computer Being Run For Long Time Without Reboot.MR
- Filming is extremely Slow Due to Network Hub in Operator Workspace.MR
- Apparent Image Reconstruct Fail Blank Image Due to ASSET Calibration Scan Done at Wrong Location.MR · 2227991
- Auto Prescan Fails Due To Center Frequency Off By 2000 hz.MR · 2224666, 2224725
Full cause & resolution for every GE MR issue
Unlock the complete cause analysis, step-by-step resolutions and attached service documents — re-authored, web-first, searchable.
Start free trial7-day free trial · no credit card required