Error Messages for MFO Systems refer to Rear and Front of BRM, which doesn't exist on Ovation.
Symptom
Error Messages for MFO Systems Refer to "Rear" and "Front" of BRM, which doesn't exist for Ovation5 systems. See long description. Error Messages for Ovation5 Systems Refer to Rear and Front of BRM, which doesn't exist for Ovation systems An FE encountered the following Dynamic Disable Bias Faults while troubleshooting a Ovation5 system: 2249157, 2249160 (see below). Each of these errors refer to either "front of coil" or "rear of coil", and also "FRONT of BRM" and "BACK of BRM". Evidently these are copies of the same errors from HD systems which use a cylindrical magnet and a BRM. Since the 0.35T Body coil has no "front" or "rear", and has no "BRM", the FE is at a loss as to where the system is pointing to in these errors. For Ovation5 the errors need to specify top or bottom. These error messages, and there are undoubtedly others like them, must be rewritten to properly identify the problem area for Ovation5. I suspect the same problem exists in previous incarnations of Ovation as well, such as on MFO3 & MFO4
Error message
2249160 Dynamic disable fault Rear of Coil open Dynamic Disable bias fault on back drivers. 2249160 lx-mr NSP SCP:../TrDriverMdsHWO.cpp 1691 Dynamic disable fault, Rear of Coil open Dynamic Disable bias fault on back drivers. Possibly a disconnected cable between the driver board and the dynamic disable switch boxes, or an open diode in dynamic disable switch boxes on BACK of BRM. 2249157 Dynamic Disable And T/R Driver Board Error Wed Aug 4 10:56:19 2004 Error: 2249157 Host: SIG1_OC0 Process: NSP File: SCP:../TrDriverMdsHWO.cpp Line: 1360 Dynamic disable and T/R driver board error. A spurious dynamic disable fault occurred. It cleared itself before the specific problem could be read. Possible causes: Noise on the dynamic disable board or a bad board.
Applies to
- Models
- Ovation
- Product
- Ovation with EXCITE
- Software
- OVATION5 Applies to Ovation5 (Excite) only. Ovation5 is 12.x platform software, not OvationHD.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100060 Unable To Film.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.
- Having Difficulties Setting Up Gradcal Scan From Dir 5112585 - Signa Ovation With Excite Technology
- CWA ID101091. Some or All Images in the Last Scan Did Not Reconstruct.
- HFO Cradle Will Not Move Due To Loss Of Home Flag Position.