GE MR — field troubleshooting
9,114 field-service issues · page 108 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- MDS Failures Due to Reversed Fiber Optic Cables TX MDS and the RX MDS at the STIF.MR · 2248662
- Computer Does Not Recognize The MOD Drive Due to The SCSI Card inside the HP PC failed.MR
- Auto and Manual Prescan Fails.MR · 2224667, 2255075
- Corrupt Image Database.MR · 10290
- Loud Knocking Noise when Table Is Raised And Lowered.MR
- CWA ID86707. Cold Reset Message occurs during Reboot.MR
- Scan Aborts with MDS Link Error 2248666 Due to CPDMR · 2248674
- CWA ID86712. Internal software error uable to scan.MR · 2223621
- Confusing Procedure for Loading Correct Version of Proprietary Magnet Monitor SoftwareMR
- The Power Supply in the System Cabinet BIT3 FIBER OPTIC MODULE Was Low at 4.8 VDC.MR · 2227973, 2227972
- The BIT 3 FIBER OPTIC INTERFACE Module in the Octane Computer Cabinet Failed.MR · 2227972, 11829
- Site Purchased the PROSE Option, But No MRS Phantom Was Provided.MR
- CWA ID86807. Corrupt Image Database.MR
- CWA ID86837. SGA Power Supply Errors May be Erroneous.MR · 2244585
- Defective coil.MR · 2225554
- Unable to Print Due to No Communication Between the DASM and Camera.MR · 14070
- Octane Computer Crashed.MR
- CWA ID86900. Unable to Graphically Prescribe off of a 3-plane Localizer, the Graphic Prescription Window Does not Come Up.MR
- Unable to Start Image Database Due to Software Corruption Caused by PCI Cardcage.MR · 2218079
- Unable to Print at ReportCARD Workstation.MR
- Satcomm What do the LEDs on the Satellite Modem indicate How can they be used Satcomm Details on the Satellite Modem LEDs Magnet Monitor 3MR
- CD and DVD Media Compatibility and Considerations.MR
- Can not load 16 channel option key due to previously installed 8 channel option key.MR
- Unable to View Serial Communications Displayed in APS, AGP, or SCP Terminal Windows, Garbled.MR
- unable to boot brainwave PC for first time during installation Due to The stim PC requires a windows xp authentication code.MR
- MNS spectroscopy requires updated revision of exciter bd.MR · 2247147, 21785575
- Where do I Find Part Numbers for Non Magnetic Tools.MR
- Magnets; Need a short List of the GE Magnet Prefix.MR
- Automated DQA tool Fails to Run Completely during Installation.MR
- Will not scan with 2248759 RF Amplifier Response Timeout Due to SRFD2 RF Amplifier.MR · 2223621, 2248759
- HP Video Card. System is booting on the small monitor.MR
- Gradient Error 2244573 GP Reporting X Axis SGA Internal Wiring Fault Due to SGA Board.MR · 2244573
- HP boot up fails when checking file systems Due to Corrupted Software.MR
- Error After System Boots But Scanning Normally, What Does The Message Mean?MR
- Unable to select bodyfull with the 12 channel body coil.MR
- Loose power and SCSI cable connections at the serial expansion box.MR · 2219971
- How to Find The Term Server MAC Address.MR
- How Can The Scan Room Door Switch be Safely Disabled Until Replacement Arrives.MR · 2224666
- Bulb is Burnt Out.MR
- Using the wrong Auto Install Floppy Disk 2304922.MR
- Unable to archive Due to svst File.MR · 10191
- MFO IV Service Document incorrect information for Magnet Enclosure type in system config file.MR
- Unable to Select Reflected Power in Body UPM Calibration on HDe System.MR · 5144304
- How Do I Change the ConnectPro Date Format.MR
- Mechanical installers did not install the new cat 6 cable properly in the systems cabinet during the upgrade.MR · 2223859
- CWA ID87507. 2248356 SSI Watchdog Timeout Due to Loose Power Plug on back of the MGD.MR · 2248356
- Cannot run SNR test on * channel Body upper nor 8 channel body lower coils.MR
- PSD download errors on any 8 channel coil Due to DRF Board.MR · 2248130, 2218592
- Oil Leak Under HDe Lite Table.MR
- CWA ID87640. How To Shutdown A Linux System.MR
- Can not get the vertical marker to set on the peak when in manual prescan.MR
- Defective Fiber Optic Cable Run # 712.MR · 2254702
- The water flow was low, causing the compressor to over heat.MR
- Will Not Scan With RF Errors.MR · 2225756, 2225757
- How Can I Make MCR (MultiCoil Receive Chain Troubleshooting Tool) Work for 1.0T Systems.MR
- Pulse Sequence Type and Sequence Variant Information Annotation Blank on Some PACS Systems.MR
- Will Not Scan With Patient Comfort Sensor Trip.MR · 2225687
- CWA ID87871. Browser Out Of Sync Due To Operator Deleting Images During Reconstruction Of ADC Map Images Browser List Suddenly is Empty.MR · 2219864
- Will Not Print Due to Wrong Camera Selected.MR · 14145
- Disk Partition Full.MR
- When an exam is created from a worklist patient with the Exam Description field filled in, you cannot edit this field with scan Rx.MR
- Entries in the Patient Register Could Not be Removed.MR
- Cannot Save Protocols to MODMR
- Loader shell's positioning crosshairs potentially do not line up with inner positioning crosshairs on DQA phantom.MR · 2321556, 2371512
- The 3T Passive Shim Kit is not listed as a FRU.MR
- Short Circuit in 16 Channel Switch caused failure in SRI.MR · 2261176
- What is the Phone Number to Contact Lindgren about Shielded MR Scan Rooms.MR
- What Does message Error in function emTimerSet Indicate.MR · 200002301
- Stimulus PC Stops Running the Brainwave Paradigm During fMRI Scan Due to The customer was pressing the Escape button on the StimPC while inside the fMRI study.MR
- No Documentation to Configure Codonics Printer for SAGE for 11.0 and 12.0 Software.MR
- CWA ID88207. PDU was in stop mode.MR
- CWA ID88215. Planned Maintenance PM Schedules Window Pops Up On The Screen Due to Too Much Time Since Last Planned Maintenance.MR · 2218670
- LX system is unable to network to any host on the network.MR · 11002, 14145
- Defective Analogic RF amplifier.MR · 2225750
- CWA ID88332. Auto Prescan failed, RF Amplifier is not ready.MR · 2225478
- How To Create an Anonymous Patient.MR
- How to Select Full or Partial Patient Anonymization and What are the Differences.MR
- Error Log Filling Up With ermes Errors With no Apparent Affect on the System.MR
- Can not select any 8 Channel Coil Due to Correct AP and DRF boards not installed.MR
- CWA ID88351. While building protocols the system locks up.MR · 200002352, 200002