Loader shell's positioning crosshairs potentially do not line up with inner positioning crosshairs on DQA phantom.
Symptom
Loader shell's positioning crosshairs potentially do not line up with inner positioning crosshairs on DQA phantom See Resolution concept for the complete SMILe released 03/22/2007. Subject:Crosshairs on Loader and DQA Phantom Not Always Aligned in DQA Phantom with Loader Assembly Used with Split Head Coil. Effectivity:All DQA Phantom and Loader assemblies, part numbers 2321556 and 2371512, manufactured before FW 17 (week of April 23), 2007 and used with 1.5T and 3.0T Signa MR Split Head Coils. Problem:Loader shell's positioning crosshairs potentially don't line up with inner positioning crosshairs on DQA GE Healthcare SMILe's and Service Notes are copyright (c) to General Electric Company Inc with all rights reserved. SMILe's and Service Notes issued by GE Healthcare are proprietary to GE Healthcare. Disclosure to persons not employed by GE Healthcare or not in possession of a Advanced Service Agreement with GE Healthcare is prohibited. See Resolution concept for the complete SMILe released 3/22/2007 Subject: Crosshairs on Loader and DQA Phantom Not Always Aligned in DQA Phantom with Loader Assembly Used with Split Head Coil. Effectivity: All DQA Phantom and Loader assemblies, part numbers 2321556 and 2371512, manufactured before FW 17 (week of April 23), 2007 and used with 1.5T and 3.0T Signa MR Split Head Coils. Problem: Loader shell's positioning crosshairs potentially do not line up with inner positioning crosshairs on DQA phantom.
Applies to
- Models
- Excite, Signa
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- 2321556 1.5T DQA Phantom with Loader From the Signa HD & HDx 1.5T FRU’S DIRECTION 5166012 Revision 1 Documentation. To view the most recent appropriate and detailed documentation, click to go to MR Service Documentation.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.