MRIQ Shading in Images See long description Image Parameters Exam Description L-SPINE Series Description T1 SA…
MRIQ Shading in Images.
Symptom
MRIQ Shading in Images See long description Image Parameters Exam Description L-SPINE Series Description T1 SAG Anatomic Reference SN Scan Protocol Name Patient Weight (kg , Lb) 86 , 190 Image Type GE Advantage Windows Image Format Rectangular Image Matrix (pixels) 512 Image Suite ID #GEMS Study number 3128 Series number 3 Image number 6 Series Date & Time Nov 19, 1998 9:41:41 AM Image Date & Time Nov 19, 1998 9:41:41 AM Contrast information NO C Display FOV (mm) 300 Slice Thickness (mm) 4.0 Magnet Strength (Gauss) 15000 Number of excitations 2.0 Number of echoes 1 Flip Angle for GRASS(°) 90 TR (ms) 500 TI (ms) 0 TE (ms) 13 TE2 (ms) 0 Center Freq.(0.1Hz) 638915050 Auto Center Freq(0.1Hz) 638915050 Auto Trans.Gain(0.1dB) 170 Prescan R1 Analog 11 Prescan R2 Digital 15 SAT fat/water/none 0 Variable Bandwidth(Hz) 15.625 Nb of slices in this group 12 Phase contr. flow axis 0 Phase contr. velocity encoding 0 Prescan Flag Auto Prescan Succeeded Pulse Seq. Name fse-xl PSD Name FSE-XL Coil Name CTLBOT Slice Location (mm) -23.3 Scan Spacing (mm) 1.0 Recon. x (mm) -23.3 Recon. y (mm) -18.0 MRIQ Customer Image Library
Error message
2224713 No successful FTG check in X iterations APS1 will run automatically. Error: 2224713 Host: DMHMRI Process: NSP File: APS:aps_exec Line: 1 No successful FTG check in 2 iterations. APS1 will run automatically.
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.