GE Healthcare · MRExcite224485122445772244578
2244851 Gradient Amplifier Y-Axis Current Distortion fault due to defective TRM.
Symptom
Will Not Scan in Zoom Mode with Gradient Amplifier Current Distortion Faults. See Long Description Will not scan in Zoom gradient mode with gradient amplifier current distortion faults logged. There is no problem when scanning in Whole gradient mode.
Error message
2244851 The GP is reporting a Gradient Amplifier %c Axis Current Distortion Fault. the same error as 2244577 on 11X, G3, openMR4 and 2244578 on 12X, E2, 14M4 (HDx, HDe), and openMR5. See Long Description 2244851 error code on Post 14M5 and 12.0 M5, is the same error as 2244577 on 11X, G3, openMR4and 2244578 on 12X, E2, 14M4 (HDx, HDe), and openMR5.2244851 The GP is reporting a Gradient Amplifier %c Axis Current Distortion Fault Example error message (could be any gradient axis, Y-axis is shown in this example): Error: 2244851 Host: lx-mr2 Process: NSP File: SCP:Grad Line: 2851 The GP is reporting a Gradient Amplifier Y Axis Current Distortion Fault.-> Extended error message This is a generic fault message indicating that the Gradient Amplifiers are not accurately following the current command from the IPG/SRF. If other faults occurred concurrently, they will provide useful information to assist with troubleshooting. Else, swap the control cable between the GP and the failing Gradient Amplifier with the Gradient Amplifier on another axis (swap one end of the cable only). If the fault moves, replace the Gradient Amplifier or Gradient Amplifier Control Board (board can be swapped with
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- SecondOpinion 3T 1.5T TRM 2144093-9 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.