GE MR — field troubleshooting
9,114 field-service issues · page 5 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Auto Prescan Fails Due To Center Frequency Off By 2000 hz.MR · 2224580
- MRIQ Profile Ghosting in all Axis.MR
- Medcam AP Reflex 50 and 100 Upgrades And Compatibility.MR
- Gradient Data Overrange Occurred.MR · 2241535, 2241534
- Coil ID Light is Always Green.MR · 2220007, 2218630
- TG Reached the High Limit Due to the 3T RF Body Coil. 3T Excite HDx 14.0 M5.MR · 2224713, 2224666
- CWA ID107298. Applications Software Will Not Boot.MR · 2223850, 10303
- Image partition on hard disk full..MR · 10182, 11007
- PM Check Fails with no Valid SPT PM Data Files were Found Message.MR
- Unable to download TPS or ISE or MGD chassis Due to Dual PPC Module.MR · 2227964
- Unable to Add Second Disk Drive in Install GUI on Octane Computer Due to Unmatched Drives.MR
- Large Patient Knee Scan with Low SNR.MR
- Unable To Scan With Driver Module Errors Due to 3T MKS RF Amplifier. 3T Excite HDx 14.0.MR · 2247161, 2247160
- Cannot Scan With intermittent TR and Dynamic Disable Faults.MR · 2252312
- Why does the HDe UPM Functional Check Troubleshooting Procedure State to Modify Body Cal Code in Head Mode.MR · 5144304, 13191659
- CWA ID107471. Unable to Download or Reset The TPS MGD or ISE.MR · 2254012
- How To Troubleshoot (repair) PCI Bridge PCI/GIO Errors.MR
- Coil ID Validation Error Caused by Coil Cable on 3.0T Quad Knee Coil.MR · 2262134
- CWA ID107486. Archive Status States No On All Exams After A Forced Database Reset During Boot up to Applications Due to Software Design.MR
- Axial images rotated due to fiber optics reversed at the Gradient Processor.MR
- CWA ID107509. Scanner stopped during scan.MR · 2249352, 2249321
- CWA ID107521. Auto Prescan failed, RF Amplifier is not ready.MR · 2225470
- MRIQ Black Band Artifact on FSE Images.MR
- CWA ID107525. Unable to scan with message Prescription allocation request fail.MR · 2218527, 2217995
- cx alarm He Level Low.MR
- During system operation, bus error occurs and system reboots unexpectedlyMR
- MRSPT Hangs on Eddy Current Test due to the Language Selected in Guided Install GUI due to a Software Bug.MR
- Octane computer will not boot.MR
- Can we do SAVEINFO on a CDROM in version 11.0?MR
- Protocol PSD Download Fails Due to MNS Exciter. 3T Excite HDx 14.0. 2247151 IRF Driver Function Failed to write a control value to the RRFMR · 2247151
- SCP2 board not installed in MGD Chassis.MR · 2256460
- 2252302 Multicoil Bias Fault due to defective coil cableMR · 2252302
- What Year Was My Magnet Manufactured.MR
- Images Slow to Reconstruct or Overall System Performance seems Slow Due to Corrupt Image Database.MR
- How to annotate information onto an image to be visible in a JPG format so the ACR images will show the annotation.MR
- Array Processor Errors Due to Master AP Board.MR · 2228010, 2228016
- Accidental Push of E-stop Button.MR · 2248662, 2248668
- Auto Transfer By Exam Only Allows Selection of One Remote Host From List Due to System Design.MR
- Software LFC fails during Applications load with message Set System Failed Due to No Selection for a NEC 1980 MonitorMR
- Multicoil open circuit fault due to damaged CTL cable.MR · 2224709, 2225551
- twinspeed alarm Water Flow Low.MR
- Customer's chiller is operating outside of specifications.MR
- Unable to Reset the TPS Due to the SCSI Expansion Box.MR · 2223840
- VRE Configuration Failed Due to ICN.MR
- Disk Partition Full.MR · 2218527
- Black and white grid on monitor Due to HP 8000 Computer.MR
- Coil ID Fails on All Multi Coils Due to 8 Channel Switch.MR · 2258107
- CWA ID108152. Fails TPS Reset when booting up to Applications or when Resetting TPS.MR · 2225691, 2225334
- Magnet Monitor 3 software update from 1.54 to 1.56 defaults Shield Cooler incorrectly.MR
- Will Not Print Due to Wrong Camera Selected.MR · 14145
- CWA ID108194 Asset Scan is outside of the Calibration Scan region.MR · 2227991
- Auto Prescan Fails with Signal Too Small on Multicoils. 2412286 FRU, 1.5T BREAST COIL w/o cable .MR · 2224725
- Unable to Boot Due to System Cabinet 8-Port Ethernet Hub Communication.MR
- SCIM Failure Caused TPS Reset Failure.MR · 2248592, 28727
- Corrupt Protocol.MR
- RF calibration not in specification.MR · 2225714
- 1.5T Extremity Coil (Quad Knee/Foot Coil w/o cable) was causing error 2224589 and grainy images.MR · 2248016, 32754
- Inhouse engineer had a valid service key but was unable to access proprietary tools because proprietary software had not been loaded.MR
- How can I find out what process created a core.MR
- Zipper artifacts due to missing several Gold fingers in screen room door.MR
- Collapsed Images Due to STIF Board.MR · 2248016, 32754
- Corrupted Entries In the /usr/g/protocols/patients/exam and series Directories.MR
- The Download of a Prescribed Series Failed Due to Remote RF Master Exciter.MR · 2248259
- Unable to Ping icn1-bmc and icn2-bmc.MR
- MRIQ Black Bands through Anatomy Due to Medcam.MR
- CWA ID10859. MRCustomerCall Image Quality OVERRANGE IMAGE ARTIFACT.MR · 2234211
- MRCustomerCall Image Quality Zippers / Banding due to Multiple-System Cross talk.MR · 50158, 638842710
- CWA ID108600. Cannot use Edit Patient Data on an Exam because the Exam is already in use.MR · 16027
- PDU in Stop Mode and TPS Download failure.MR · 2248602, 2244588
- How to order PPG Photoplethysmograph probe for PAC physiological acquisition controller.MR
- The Main Disconnect and PDU Power Breaker Tripped due to Incoming Power problems.MR
- Option is Unavailable after Loading with eLicense.MR
- CWA ID108664. MOD Will Not Eject or Detach Due To MOD Drive Hung.MR
- CWA ID108861. No respiratory gating signal at input to system cabinet.MR
- CWA ID108699. Corrupt Protocol.MR
- How Do We Get Vendor Service Support for the Compact PDU.MR
- The system host name had an invalid character (the underscore) in it.MR · 14148
- HFO alarm water flow low.MR
- Unable to Scan with 3T MKS RF Amplifier Due to RF Amplifier.MR · 2261230, 2254342
- Exciter Calibration Errors And Power Monitor Trips only when using T/R knee coil. due to defective CERD exciter.MR · 2225739, 2234496
Full cause & resolution for every GE MR issue
Unlock the complete cause analysis, step-by-step resolutions and attached service documents — re-authored, web-first, searchable.
Start free trial7-day free trial · no credit card required