GE MR — field troubleshooting
9,114 field-service issues · page 95 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- CWA ID 61036 Error Code 03 On Magnet DisplayMR
- CWA ID 61171 How do we power down and up the Profile 3/4 system?MR
- How to Adjust the Mouse Speed.MR
- Software Issue.MR · 2218086
- Intermittently unable to download or scan the Propeller PSD Due to the Eight Port Ethernet Switch.MR · 2256458, 2256853
- Linux OS Successfully Installs but Unable to Install Application CD.MR
- MagMon3 Helium Meter codeMR
- MagMon 3 Uptime.MR
- Coil ID fails for any coil connected to the upper LPCA port, but Coil ID works fine for any coil connected to lower portMR · 2220008, 2224854
- Faulty Cables In Some Signa HD Systems May Cause TPS Reset Failures or Unable to Login Using MGD_Term Script.MR
- REPLACING THE SUMITOMO CSA-71A HELIUM COMPRESSOR ON THE MOBILE UNITSMR · 61004
- Alternate Head Transmit path to the A port was added during the 12.0 upgrade.MR · 2252293, 2252305
- cannot load SP2 from FMI 60732 Due to FE put the CD in the DVD drive in the SCSI tower instead of in the HP8200 CD drive.MR · 60732
- Is it Possible to Remotely Remove Purchased Option Keys?.MR
- Software Updates Have Transferred from Quickplace to Support Central MR Software Download Web Site.MR
- OpenSpeed Service Methods (2402212-1) Rev5 does not describe boot up command of Linux OS Load for OpenSpeed 4 system . (Software/System Host Software/Host Load From Cold LINUX Computer /Host Operating…MR
- Cannot Pull Worklist from Broker Due to Date on the Host is Set Wrong.MR
- CWA ID61456 Will Not Scan With RF Errors.MR · 2254347
- It is sometimes difficult to attach the lifting brackets to the SGA or HFA FRUs.MR · 2393906, 2270055
- Milwaukee reported partial leaking (of water condensation) on several Magnets during Bay testing, this was due to inconsistent RTV caulking seal between the OVC and Drip Trays.MR
- Unable to Scan with X-Axis Current Distortion & Overcurrent Faults.MR · 2244578
- CWA ID 61651 Corrupt ProtocolMR · 2224893
- What Is The Catalog Number For MRI Patient Leadwire Set.MR
- Pop up message appears when patient is selected from the ConnectPro Schedule Due to Action Items sent from the RIS are not mapped out.MR · 2219940, 0072146
- Grafidy3 error for dc offset on 8645 base system.MR
- Unable To Run EPIWP Manually (From A Cshell).MR
- Images not showing up in browser due to corrupt image data base.MR · 10097
- Unable to Download or ResetTPS. 3T Excite HDx. 2223864 An executable file necessary to run image reconstruction cannot be copiedMR · 2223864
- MOD drive is hung and requires reboot.MR · 10033
- Unable to Run MCR Tool Due to Multi coil Faults were not disabled.MR
- MRCustomerCall Image Quality Ghosting Artifacts Due to Patient Motion.MR
- How Do You Remotely Determine the Netmask?MR
- Cannot DICOM Network Images Due to A back slash in the Protocol Name.MR · 11057
- TPS Fails Reset After CPC MNS Amp Option Installation on a 3T HDx. 3T Excite HDx 14.0. 2261238 The ASC BB IF Board was detected but is not configured in MRconfig.cfgMR · 2261238
- Cannot scan HNS coil with MQCA SNR tool.MR
- Unable to Scan a Phantom With RF Errors.MR · 2254051, 2254052
- Lost entire exam from the browser while editing Exam Data and accidentally Deleted the Exam.MR · 1093010919, 16027
- Defective USB to Serial cableMR · 2220071, 2220078
- Need to enter Net Mask In decimal and can only find it in Hexadecimal format.MR
- How To Create, Transfer, And Delete A SPRSNAP.MR
- What Does scsistat Command Show When A MOD Is Successfully Attached.MR
- OrthoMRI How To Tell If E-Scan (Unix) Is Digital Or Analog Hardware Version.MR
- New User CV in 12.0 and later for TOF and vascular family of scans called Vessel Uniformity.MR
- Power cycling can corrupt TPS Communication and Operating System software.MR · 2227994, 2218527
- Insufficient TPS memory installed to support large data collection pulse sequences back-to-back.MR · 2227994, 2218527
- Intermittent failure in Downloading of PSD's and Autoprescan failures.MR · 2219712, 2218630
- SecondOpinion 3T 35kW RF Amp 5104896.MR · 5104896
- Cannot Edit Patient Data.MR · 16003
- Corrupt Protocol.MR · 2234128
- Auto Prescan Fails With No Signal Due To the Wrong Coil Entered in the Protocol.MR
- Scan Stops Due To Coil Not Closed Completely.MR · 2224589, 4062796
- Coil ID Light Stays green with No coil Connected Due To ESD Filter on 8 Channel Switch.MR · 2220007
- What Does message Error in function emTimerSet Indicate.MR
- System Does Not Recognize the 0.7T Wrist Array Coil.MR · 2258106
- The FE had the cables attached to the shim supply and the magnet room door was not closed so the RF leak picked up by the UTNS antenna cut off receive signal.MR · 2224580
- Unable to archive Due to svst Files.MR
- PM SPT was missing all test results.MR · 2218600
- Will Not Scan with Gradient Errors.MR · 2248108
- Getting VTOC Overwrite error during LFCMR
- Text Annotation on Images Does not Transfer When Networked or Archived.MR
- Corrupt Dat Tape.MR
- MC Power Supply output too lowMR · 2262701, 2262724
- Excite HDx. MRSPT.MR · 2250082, 2250081
- Dark Bands in Images Due to Overlapping Graphically Prescribed Images.MR
- Root Password Is Not GE Standard Password Due To Site Changing Password.MR
- clarify 11.0 options Matrix.MR
- Problem was caused when the pre contrast series did not finish reconstruction.MR · 2224379
- Coil not plugged in properly.MR · 2220007
- Geometry errors Due To Software Update ServicePack-02.MR · 2218682, 2218680
- Images Are Not In The Browser Due To Database Out Of Sync.MR · 2243501
- No Body Receive Signal after HDx Upgrade.MR
- Intermittent Image Reconstruction Failures Due to AP Board.MR · 2227964
- What are the Details of the 1.5T SIGNA HDE LITE TABLE MCAT number M20022FK Top level Part 5146014 and how does it Differ from the Standard Signa Table.MR · 5146014
- Image Filter Button Greyed Out or Unavailable, Corrupt Software.MR
- Unable to Download or Reset The TPS MGD or ISE.MR · 1093269752, 093798480
- Unable To Scan With Driver Module Errors.MR · 2252357
- Images Not Displayed In The Viewer Or The Browser.MR · 2228718, 2228010
- Pop up message appears when patient is selected from the ConnectPro Schedule.MR
- How Do I Reload IVI (Interactive Vascular Imaging) Option Software on HDx?MR
- The ACGD/HFD SGA Power Supply has a heatsink overtemperature fault even though the equipment room temperature is less than 9C (48F).MR · 2244589, 2244590