Coil ID fails for any coil connected to the upper LPCA port, but Coil ID works fine for any coil connected to lower port
Symptom
Coil ID fails for any coil connected to the upper LPCA port, but Coil ID works fine for any coil connected to lower port See Long Description for the errors logged. Note that error code 2224854 appears immediately on almost every applications software boot, and at other times as well. Tue Jan 16 23:39:31 2007 2224854 2 LXTS NSP SCP:SRI 350 SRI-8 Channel Switch Comm Error. SRI received packet from the 8 Channel Switch which did not include all parameters. If "Actual Cnt" is 0, fiberoptic cables between SRI and 8 Channel Switch may be disconnected. Cmd: 4 Expect Cnt: 5 Actual Cnt: 0 Tue Jan 16 23:42:22 2007 2220008 5 LXTS scn RxMgrDownload.m 2157 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. Upper coil connect status:1, Upper coil code:Null, Lower coil connect status:0, Lower coil code:Null Tue Jan 16 23:42:22 2007 2218630 4 LXTS scn RxManagerIF.m 951 The download of a prescribed series failed. Internal status code is 2220008.
Error message
2220008 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. 2220008 5 NSR334 scn RxMgrDownload.m 512 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. Upper coil connect status:1, Upper coil code:Null, Lower coil connect status:0, Lower coil code:Null 2224854 SRI 8 Channel Switch Comm Error. SRI Received Packet from the 8 Channel Switch which did not Include all Parameters. Wed Apr 14 08:32:03 2004 Error: 2224854 Host: exmr Process: NSP File: SCP:SRI Line: 350 SRI-8 Channel Switch Comm Error. SRI received packet from the 8 Channel Switch which did not include all parameters. If "Actual Cnt" is 0, fiberoptic cables between SRI and 8 Channel Switch may be disconnected. Cmd: 4 Expect Cnt: 5 Actual Cnt: 0 2218630 The download of a prescribed series failed. 2218630 Host: Andys3T Process: scn File: RxManagerIF.m Line: 556 The download of a prescribed series failed. Internal status code is 2218501.
Applies to
- Models
- Excite, Signa
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- 2362995-2 Eight 8 Channel Switch
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.