GE MR — field troubleshooting
9,114 field-service issues · page 111 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- The ConnectPro Worklist comes up empty when updated on the MR system.MR
- Patch CDR Not Seen by System During Patch Installation.MR
- TR driver Fault Body Path Short Due to CPD Board.MR · 2225520
- No Automated SNR Test Available in HDx for 4 Channel CTL Coil.MR · 13091904
- Unable to Locate DC Offsets Calibration Procedure After ACGD-Lite SGA Replacement.MR · 2402212, 13156427
- Coil missing after software installMR
- Tech closes Ilinq window by clicking on the "x" in upper left of window.MR
- When scanning epi with standard head coil on an Excite system, the images come out just noise.MR
- Patient comfort trips due to faulty SRI.MR · 2248655
- Selected right knee coil when intending to select left knee coil.MR
- Missing ECC Coeficient Files Due to Grafidy3 Not Run.MR · 2252735, 2261245
- Loud Knocking Noise when Table Is Raised And Lowered Due to The rubber bumpers on dock unit were worn out.MR
- Illegal Character In The Localizer Protocol NameMR · 2224382
- Cradle will Reverse Direction when moving toward Home Due to Dock Motor Short.MR
- Intermittent Image Reconstruction Failures Due to AP Board.MR · 2228010, 2228016
- How do I adjust the PC clock running windows 98.MR
- 2252239 Startup Timeout was detected on the Drivers Control Board due to Driver Module.MR · 2252239
- Who do you call for service on a GEAR mobile. 1-888-367-4327.MR
- Unable to Scan With HV Supply Low, Front of Coil Short & Rear of Coil Short Always Logged.MR · 2249147, 2249159
- Unable to Scan due to to incorrect Line Frequency selection in the Install Gui.MR · 2222279
- CWA ID93588. Protocol PSD Download Fails.MR · 2217489
- GAIN STAGE ON RF AMP NOT ADJUSTING PROPERLY.MR · 2224589, 4062796
- Auto and Manual Prescan Fail when using the 8 Channel Body Array Coil.MR · 2252293, 2252301
- FE adjusting wrong pot on the Intercom board.MR
- Option conversion script failed during upgrade or saveINFO was not used.MR
- Unable to Download or Reset The TPS MGD or ISEMR · 2234498, 2237285
- Can We Scan With The Body Coil While Another Coil Is In The Bore.MR
- CWA ID93849. Keyboard And Mouse Not Working Due To Cable Pulled Out Of Wim.MR
- Current Distortion Faults Due to HFA CONTROL BOARD ASSEMBLY.MR · 2245053, 59528
- No signal on any Scans With no errors in log Due to Driver Module.MR
- Gradient Overvoltage Faults due to a failed HFA Control board.MR · 2244576
- AP failure due to memory module.MR · 2227966
- LCD Monitor Uniformity is Not Linear Across The Entire Display.MR
- Unable to log in due to password has changed.Unable to log into sdc, signa or mobile account.Reset Password to default. - wqr.Signa LX 9.1MR
- May Two Coils Be Connected to the MSHS Simultaneously.MR
- HDe Gradient Internal Wiring Fault Due To Control Board Assembly.MR · 2244851, 2244577
- CWA ID93985. How Can Customer Order Accessories When The Web Site Is Down.MR
- could not scan...getting error that prep action failedMR · 2225061
- Will Not Scan with Gradient Errors.MR · 2250082
- Unable to Download or Reset The TPS MGD or ISE.MR · 2246047, 2223621
- What is the 800 number for GE Healthcare Accessories and Supplies.MR
- Unable to Scan with Current Distortion Fault and No Lights On Any HFA Amplifier Including Control Board.MR · 2224666, 2244570
- Scans Abort with Gradient Amplifier Z-Axis Undervoltage Fault.MR · 2245100, 741345
- Can a HP 8000 be Replaced With a HP 8200, What are the Differences Between them.MR
- PAC respiratory waveform is flat line, PAC LED's bar does not move with bellows motion.MR
- FE did not check for new options to download from the eLicense web site.MR
- The DICOM Standard Does Not Allow the Use of 5.2GB MOD Media at this Time.MR · 10179, 10208
- CLARIFY Oxygen Alarm Sounds Intermittently and Can Be Reset.MR
- FE looking to change the MGD IP address scheme due to a change request by the hospital to update the Scanners IP address.MR
- Magnet Monitor 3 installed to replace a SHeM.MR · 2225113
- Network will Not Negotiate to full Duplex, Network is very slow.MR
- CWA ID94259. Ovation MFO Knee Coil Wire is Exposed.MR
- The Power Supply in the System Cabinet BIT3 FIBER OPTIC MODULE was Low at 4.8 VDCMR
- System is in non-proprietary mode.MR
- How can you view Printer configurations remotely.MR
- Edit Patient Data Button is Missing From Browser.MR
- How To Order Components for the MDP Main Disconnect Panel on Profile1 through 5MR
- Scan Pauses With Erbtec 32 Fault Due to U17 on Processor Board.MR · 2225622
- Table will not undock due to stretched cable in table.MR
- How to Change the Site Name on A Signa Advantage. 5.XMR
- What are the Jumper Settings for the Replacement 36 GByte HP Hard Drives. 36 Gig Fujitsu Hard Drive Information.MR
- Scans pause due to defective RF Door Switch.MR · 2248612
- MiniGRAM undervoltage faults caused by MiniGRAM or MiniGRAM PS.MR · 2234211, 2241515
- 3T rf amplifier power level degrades with time. 3T amplifier is a tube amp which needs periodic re calibration.MR
- RF amplifier power was high, causing intermittent power monitor to trips.MR · 2254051
- Cold Head Is Not Running.MR
- O2 Alarm Sensor is Defective.MR
- Can not Network or Ping to an AW Workstation Due to AW Network Configuration.MR · 11010
- CWA ID94626. Emergency Stop Button Accidentally Hit, How to Recover and Start System.MR · 2218537
- With the FE Service Key Installed, the System Defaults to Installation Calibration Wizard (ICW)MR
- MRIQ Profile Ghosting in all axis Due to Poor Connection of the Neutral Conductor.MR
- Preventive Maintenance (PM) Schedule F Requires Cardiac Gating Cable Test Due to an Error in Documentation.MR · 5155500, 640042
- The serial port on the PC is defective.MR
- CWA ID94706. Scan Aborts with MDS Link Error.MR · 2225704
- CWA ID94709. Can Not Scan.MR · 2218592
- FE is unable to connect to SHEM with Dell D630 Laptop.MR
- How to Determine if Functool Is Installed. 3T Excite HDx 14.0.MR
- Scan Pause and Bright Zipper or Band in Images caused by TWIN GRAD SWITCH BOX.MR · 2244648
- Is PURE Available on 11x Excite or 3.0T Platforms ?MR
- 420V ACGD Breaker Trips Due To a Bad SGA Power Supply. 420 Volt ACGD Circuit Breaker On The PDU Is Tripped OFF.MR · 2244588