GE Healthcare · MRExciteSigna2224666224457022445782248645
Unable to Scan with Current Distortion Fault and No Lights On Any HFA Amplifier Including Control Board.
Symptom
Unable to Scan with Current Distortion Fault and No Lights On Any HFA Amplifier Including Control Board Unable to Scan with Current Distortion Fault and No Lights On Any HFA Amplifier Including Control Board. 2244578 The GP is reporting a Gradient Amplifier % Axis Current Distortion Fault
Error message
2224666 Auto Prescan failed, Master Gradient is not ready 2244570 The gradient amplifier failed to go to Ready when commanded. 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded.-> 2244570 TOiMR2 NSP SCP:Grad 1106 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Spin Echo Coil: US SHOULDER PA Scan: 379/4 The X Axis gradient amplifier failed to go to Ready when commanded. 2244578 The GP is reporting a Gradient Amplifier % Axis Current Distortion Fault 2248645 Master Gradient is not ready. Error: 2248645 Host: OMR2_OC0 Process: NSP File: APS:aps_pass2 Line: 238 Master Gradient is not ready. 2224666 Auto Prescan failed, possible data acquisition error. Try again or use Manual Prescan. Wed Dec 1 09:09:30 2004 Error: 2224666 Host: lx-mr Process: psc File: PscMainControl.cc Line: 1322 Auto Prescan failed, possible data acquisition error. Try again or use Manual Prescan.
Applies to
- Models
- Excite, Signa
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- 2396050-2 HFA CONTROL BOARD ASSEMBLY
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.