GE MR — field troubleshooting
9,114 field-service issues · page 14 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- The Low Level Magnet Drift Z2 Shim Supply Keeps Resetting to Zero Amps due to the Drift Rate per Day Was Not Entered into SoftwareMR · 60642
- Center Frequency was off.MR
- CWA ID123344. Unable to Download or Reset The TPS MGD or ISE.MR · 2218661, 2223621
- Low Signal Detected Due to Head Coil.MR · 2224725
- LCC Helium Level Alarm Low Limit is determined by Florence Engineering. lcc alarm He Level Low.MR
- Entries in the Patient Register Could Not be Removed due to Corrupted Entries In the /usr/g/protocols/patients/exam and series Directories Prevent Removal.MR · 2219776
- Browser is Over The Film Window And Won't Close.MR
- Defective Gradient Amplifier.MR · 2244868, 2244573
- Intermittent Ghosting or Smearing of Image and SPT Stability Failure Due to loose gradient cable in the rear pedestal.MR
- Patient Anatomy Is Reversed On Axial or Coronal or Sagittal Views Due To Swapped Gradient CablesMR
- T/R Driver Faults Due To SSM.MR · 2249152
- Profile Software Will Not Boot.MR
- What are the Details of the Signa Oncology Package Option.MR
- What Option Keys are in LX HFO Excite and Excite HD Software sok_test Output Need a Cross Reference ListMR
- Rerun LVShim and Full SPT in PM Mode, in that order.MR · 2218672
- SHEM Helium Meter Error Caused By Unreliable HE Level Readings.MR
- PPC Module failed on AP board.MR · 2223840, 2228016
- Processor Exception Frame Errors Due to Dual PPC Module.MR · 2223822, 2232902
- Unable to Complete UPM Body Forward Power Calibration due to Popup Message Error with modify_cv due to Head Coil Was Connected.MR
- HNS coil not configured correctly. 1.5T Head Neck Spine (HNS) Coil configuration errors in the GE System log.MR · 2257017
- Unable to Download PROPELLER PSD Due to Corrupt Software.MR · 2257109, 2257118
- OrthoMRI What is the Bios password for the windows 2000 Lunar MRI system OrthoMRI Escan XQ OrthoMRI Incorrect password please enter correct password OrthoMRI cascadeMR
- OrthoMRI Fill port screw is loose causing leakage of phantom fluid while in storage.MR
- Unable to Install HNS Coil Setup 3 in HNS Installation Manual.MR
- Corduroy Artifact Due to Exhaust Fan On in Magnet Room.MR · 2218672
- How to View XRFD Cold Plate Temperatures Real-Time Remotely?MR
- How Can The FE Optimize The SNR On Signa Profile System.MR
- The SDM buttons in SDM are greyed out in HDxt M3.MR
- CWA ID124003. PDU was in stop mode.MR · 2248602
- Will Not Scan ASSET due to Customer Had Started a New ASSET Calibration Scan and Then Hit Stop Scan Which Invalidates Previous ASSET Calibration Scan.MR · 2218527, 2227990
- TR Driver Faults Due to Shoulder CoilMR · 2225552
- What is the part number for the Nupro Valve for the magnet shim lead.MR
- Need part number for Swagelock Plug for the magnet shim lead.MR
- Current Distortion Fault Due to SGA.MR · 2245053, 59528
- Magnet Monitor 3 reporting that the Recondensor Si410 Cable is open or disconnected.MR
- Failed to Launch Propeller Application Due to Expired eFlextrial.MR · 2257102
- The MR PC LINUX CD (CTT Linux OS 4.5.10 DVD) is not distributed with the FMI.MR · 67807
- Vibrant scan times increased on 7 channel breast coil due to coil configuration.MR
- OrthoMRI How to set up Codonics printer on a windows 2000 based Lunar MRI system OrthoMRI Codonics Installation instructions for Escan and Cscan windows 2000 based systems OrthoMRI Escan XQMR
- Orthomri How can phase and frequency be swapped on the Lunar scans OrthoMRI ESAOTE does not allow phase and frequency to be swapped on any Lunar MRI systems OrthoMRI E-Scan (Windows) NEMR
- Corrupted Entries In the /usr/g/protocols/patients/exam and series Directories.MR
- Magnet Monitor 3 Helium Level Alarm Low Limit is determined by Florence Magnet Engineering. siiii2 alarm I2 HeLevel Low.MR
- Magnacoustics Music System Documentation Missing or Need Tech Help Parts.MR
- FE found the cold soldering in anterior portion of Knee coil.MR
- No signal on one side of TMJ Dual Combiner coil due to wrong coil Selected.MR
- How to Remotely Monitor the Discovery MR750 Cooling Cabinet (HEC) Feedback Variables, for both Current and Historical Readings.MR · 5500100
- Allocate DPR memory error due to AP Board.MR · 2248014
- Guide pins are loose and damaged making it difficult to maintain a good connection.MR · 2225554, 2225553
- CWA ID124514. Software Crashes to Wallpaper and 6 Icons.MR · 200002301
- MRCustomerCall Image Quality OVERRANGE IMAGE ARTIFACT.MR · 2234211
- How to Remotely Monitor or View the Discovery MR750 VRE Disk Drive Performance Data.MR
- Low water flow alarm due to Water Flow and Temperature Assembly Failure.MR
- Magnet Monitor devices Alarming for Coldhead Temperatures because the Checkout was not completed properly.MR
- Low Vessel Pressure Alarms due to Post Magnet Service Alarm Handling Procedure Failure. mbl alarm He Vessel Pressure Low.MR
- Can the HD Version of the Eight 8 Channel High Resolution Brain Coil Work on HDx Systems.MR · 2317112, 5146634
- On Bootup "Emergency Login" Screen Seen.MR
- Gip Reported Several PPBM Faults on the Z Axis Due to the PPBM.MR · 2241528, 2241530
- Scans Pause with RF Amplifier Heat Sink Temperature Fault due to a Kink in the Coolant Line Behind the XRFD Amplifier.MR · 2254616
- LEDs Installed Backwards LEDs are Polarity Sensitive Devices.MR
- USB Trackball and Trackball Buttons aren’t Responding.MR
- Clutch Slip During Cradle Motion Errors Logged due to Vendor May Not Be Properly Setting Clutch Tension.MR · 2268909, 50113
- Ovation scanning range is outside the head coilMR
- Download errors experienced during 8kW 3.0T MNS Amplifier Calibrations.MR · 2219712, 2147483647
- The Cradle Will Not Latch due to the LPCA Latch Hook is Physically Broken.MR
- Unable to Scan ASSET Series Due To Corrupt ASSET PSD Software.MR
- MRCustomerCall Fine line Artifact Due to Fractional Echo w/ Zip512 MRIQ040002.MR
- MRIQ Braid Pattern or Diagonal Line Artifact Due to Cross Talk and Scan Room Door Fingers.MR
- Unable to Complete Head or Body UPM Reflected Power Calibration due to Error, UPM Calibration failed due to failure to converge on a calibration point due to the FE Left the Dummy Load Connected to th…MR · 2257265, 50280
- HDe TPS Reset Fails Due to VRE Configuration.MR
- Removing core Files On Linux ComputersMR
- VRE Errors Due to ICN.MR · 2223860
- 2247383 Software Issue APS detected memory corruption while creating output filename for the anti-alias test.MR · 2247342, 219222
- Unable to scan with DCERD Temperature Error 2266418 due to Equipment Room too Hot.MR · 2244570, 2244851
- Loud noise coming out of SRFDII amp.MR
- CWA ID124838. Accidental Push of E-stop Button.MR · 2218537, 2225935
- After Downloading the Fiesta2D and Fiesta3D Options using eLicense, the Options are not installed.MR
- MOD Eject Button is Consistently Operating Even When no MOD is Present.MR
- Unable to locate the device in InSite 2.MR
- Unable to Send Images to PACS Due to Network Switch at the Site.MR · 31357
- HP Video Card. System monitor is scrambled.MR