GE MR — field troubleshooting
9,114 field-service issues · page 75 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Unable to start the MultiCoil Receive Chain Tool (MCR) baseline scan.MR
- False 3T 16 (sixteen) Channel Switch diagnostic failures seen from ports connected to "A" and "B" connectors.MR
- OpenSpeed with EXCITEMR
- IPG Sequencer RAM walking 1s and 0s test failed Due to the IPG II BoardMR · 2222267, 1094647477
- Grafidy3 B0 will Not Converge on all planes, all Other Items are Coming into Specification Due to RF ShieldMR
- “Install_In_Spec” Key Fails to PassMR · 30000
- Eddy Current test (Grafidy2 or Grafidy3) show large errors Due to eddy currents generated by moving carriage through the B0 fieldMR
- Mouse needs to move vertically instead of horizontally to get from host monitor to waveform monitor screen.MR
- Clarify Add default router on profile contourMR
- SPT Head Quick Check fails with a message "Wrong slice location has been detected."MR
- Clarify #018531 LX & CTMR
- When the table home or fast out buttons are pressed, the cradle moves 5-7mm towards the home direction immediately and then travels into the bore and stops at the mechanical stop at the end of the tab…MR
- Images Are Not Listed In The Browser but are Displayed in Autoview On A Linux HP Computer.MR · 2224340
- CWA ID23510. Cannot ArchiveMR · 10191, 10097
- Can Not Scan.MR · 2254204
- Clarify Procedure to check the resistance of the RF coil / tubeMR
- Will not scan with Air Temperature in the System Cabinet is Greater than 50 c.MR · 2247127, 74116
- What Does It Mean When Coil Is Listed As Asset Optimized vs Asset Compatible.MR
- Cannot load HD Applications Guide CDMR
- MRIQ Image Shift Artifact Due to the Bit3 VME I/F Board in the TPSMR
- Severe Image Smearing Due to Receiver BoardMR
- Dark Vertical Bands in Images Due to X axis PPBMMR
- Gating does not work and message returned on system boot or TPS resetMR · 2254702, 2225935
- Table Carriage is moving slowly Due to Clutch is too tightMR
- Advance to scan is Required Multiple times to get Table to Scan Position Due to 40-1 reducer gear boxMR
- Genesis Computer Will Not Boot With No ErrorsMR
- CWA No Video Signal Pop-up Message on Monitor.MR
- TPS or MGD Reset Fails With MDS Link ErrorsMR · 2239774
- Gradient Fails To Come Up To Ready Due to SCA LOC/REM Switch Was In The LOC PositionMR
- Warning That Equipment Room Temperature Is Higher Than NormalMR
- Unable to Create or Edit Protocols Because "setupProtocols" Script Was Executed From "root" Login Instead of "sdc"MR
- Intermittent Ghosting or Smearing Due to Z axis miniGRAMMR
- Clarify PC Is Stuck On Scandisk.MR
- Customer wants to reload the Operator Workspace PC with Windows 2000 or higher version Microsoft Operating Software.MR
- Black Bands through anatomy Due to 8607 Gradient ampMR · 2225462
- Customer wants to turn on the eMail server on the Operator Workspace PC, is this permitted?MR
- Cannot Scan, Film, or Remove ImagesMR · 2218082
- Clarify #026314 SPT Does Not Run, Error Is "The PSD Noise Could Not Be Started"MR · 2217482
- Troubleshooting information needed for the Driver Module used in 1.5T and 3T EXCITE HD 12.0 MR Systems.MR
- Is body coil compatible with ASSET scans?MR
- can't scan due to RF amp' peak power faults.MR · 2225762, 2225761
- Signa LX 9.1. The X axis minigram was shortedMR · 2241528, 2241530
- Unable to Scan Due to IT Link Fiber optic Cables.MR · 2227915, 2218527
- CWA ID24361 TPS or MGD Reset Fails With MDS Link ErrorsMR · 2248673
- Customer is Unable to Transfer Images to the AWWMR · 11074, 10435
- CWA ID2438. RF Power Monitor 1 Fault 2254051.MR · 2254051
- Cannot scan, getting Preamp Bias faults on all Coils.MR · 2240188
- Interpreting 12.X Excite HD Gather Load Data Results.MR · 2252301
- What does typical good/passing Gather Load Data results look like for the USAI/GE HD 8 Channel Breast Array Coil when plugged into Channel A of the 12.X HD LPCA?MR · 2252301
- What does typical good/passing Gather Load Data results for the USAI/GE HD 8 Channel Breast Array Coil when plugged into Channel B of the 12.X HD LPCA look like?MR · 2252301
- How to find the Error Message if only the Number is knownMR
- How to remotely find Camera name and type being used for filming, and all cameras declared on a scanner.MR
- Example typical failing open circuit Gather Load Data results for the USAI/GE HD 8 Channel Breast Array Coil when plugged into Channel A of the 12.X Excite HD LPCA.MR · 2252301
- Example of failing open circuit Gather Load Data results for the USAI/GE HD 8 Channel Breast Array Coil when plugged into Channel B of the 12.X Excite HD LPCA.MR · 2252301
- HISRIS Worklist Comes Up Empty Due to HISRIS Broker Process not running.MR · 11003, 11002
- Fails TPS Reset when booting up to Applications or when Resetting TPS. 3T Excite.MR · 2247806, 1126780121
- CWA MDS link failure and Reset TPS on Excite HD 12.0.MR · 2248670
- Unable To See Any Of The Proprietary Tools Or Access Service ProtocolsMR
- Just installed ConnectPro Option but it doesn't appear enabledMR
- OrthoMRI After the Replacement of the Hard Drive Customer could not Restore the Images from MOD.MR
- Indigo Computer Hangs During operation due to Memory Parity Error in SIMM S2MR
- 24797 Computer Will Not Boot With The Message On The Screen Says Do Not Interact With SystemMR · 200002352, 200002
- Unable to select "Schedule" from the "New Patient" windowMR
- MFO4 Ovation FE was performing FMI 67610 - Gradient upgrade from 8290 to 8295.MR · 67610
- System Applications Disk Is Full, Removing Studies Will Not HelpMR
- How do I Identiify Asset from sok_test?MR
- Are the Condor Power Supplies mounted in the front-right of the MGD chassis field-adjustable?MR
- Are the Condor Power Supplies mounted in the front-right of the MGD chassis field-adjustable?MR
- PDU is without power on mobile system. need to ID mobile type to determine proper power up sequence.MR
- Low SNR on all Channels of Standard Multicoil.MR
- After installation of software update, a slight increase in acquisition time of Oblique scans may be noticed.MR
- Clarify #027755 LX HFO Unable To Select Or Add An IVI Film ProtocolMR
- getting MC/TR driver faults / opens on multiple portsMR · 2225554, 2225553
- How to add FE to the subscibe FE to a site in PPadsMR
- Cannot Archive or Network Reformatted Images.MR
- Asset 8 Channel Body Array scan 40 FOV appears cut offMR · 2227991
- CWA Will Not Scan Due To Gradient ErrorsMR · 2241524
- Unable to locate DICOM Conformance Statement.MR
- CWA TPS Fails reset With Cerd Errors 2237275 CERD BOOT FAILUREMR · 2237275
- Unable to locate DICOM Conformance Statement.MR