GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 39 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Service Note 43681_1 Aug/06New Handset (HHC) MG/MC, MyoSight, MPR/MPS/MPTNuclear Medicine · 43681
- Service Note 43063_4 Jun/07 Starcam Polestar i Series Computers - New ESDI Floppy Drive part numberNuclear Medicine · 43063, 43062
- Service Note 43664_0 Jan/07 Scintibed II/IIb Brake UpgradeNuclear Medicine · 43664
- Orientation of the MIP (maximum intensity projection) image is misrepresented when displayed on other devices capable of viewing DICOM images.Nuclear Medicine
- How To Export Dataset (Image) in native Xeleris or Entegra dbi format using 'dbiwin' CommandNuclear Medicine
- Service Note 43711_2 Sept/07 Updated VG MCH_V Card 5197979 The MCH_V Board (PCA000492) does not support the old rotational gear with ratio 1Nuclear Medicine · 5197979, 43711
- How to export Entegra images to a Dicom file.Nuclear Medicine
- How to do a ping from the XT cameraNuclear Medicine
- I need the part number for the SMV DS7 pm tubesNuclear Medicine
- Service Note 43701_0 Feb/07 FX Tube Parts and MotherboardsNuclear Medicine · 43701, 090013
- When selecting an isotope the system gives an error of can not load offsets and dvdtNuclear Medicine
- When Millennium table was retracked it would hit the end limit switch and give Error table longitudinal axis on forward limit.Nuclear Medicine
- Network Data from Genieacq via UltraSPECT seems to be taking a long time to get to the processing stationNuclear Medicine
- After hard drive replacement, receiving error message "Not dos formatted drive"Nuclear Medicine
- Infinia / VG Gantry error #72 Drivers voltage test psd is pressedNuclear Medicine
- Millennium AUI system freezing during manual stop and resume on Static PST Flow IMMED scanNuclear Medicine
- Part Number Needed for Longitudinal, Vertical and Lateral Bearings for Millennium 3 Axis Patient TableNuclear Medicine · 212010832
- I need the password to gain access to the Multi Vender Nuclear Medicine Service CDNuclear Medicine
- Infinia hawkeye 4 QC image is rotated when displayedNuclear Medicine · 212003399
- Xeleris application does not start up - During system initialization, usually after connecting remote database, the system would crash, either on Debug Assertion or Dr.Nuclear Medicine
- Unable to read CD's archived from Entegra on XelerisNuclear Medicine
- What are the size of the bars on Ventri H3602RL Intrinsic QA Bar PhantomNuclear Medicine
- What is the Application DBs checkbox in Xeleris 2.0 System Configuration Utility - Backup / Restore tab?Nuclear Medicine
- How to move a DS camera that is stuck in collision (constant collision alarm)Nuclear Medicine
- My Microsoft Windows Taskbar has disappeared (missing) - How do I get it back?Nuclear Medicine
- Unable to save changes when editing an Entegra / Xeleris Text fileNuclear Medicine
- I need a listing and discription of the LED's, test points, fuses and jumpers on the Ventri DIB board UGP500115Nuclear Medicine
- How do I uninstall the VG Ver 6.0 Fox-Pop Patch LSW000463?Nuclear Medicine
- Infinia will not transfer data to Xeleris.Nuclear Medicine
- Ventri Position / Speed Error was generated in axis - follwowing up is done by the local Elmo driver and reported to GCU.Nuclear Medicine
- Service Note 43739_1 Jul/07 New Laptop Platform for Xeleris 2 Lenovo (formerly IBM) T-60pNuclear Medicine · 43739
- Service Note 43750_1 Jul/07 New eLicense License Mechanism for Xeleris WorkstationsNuclear Medicine · 43750
- Service Note 43752_1 Aug/07 Securing Ventry Gantry and GCU Signal CablesNuclear Medicine · 43752
- Service Note 43753_1 Aug/07 Using PMT Adhesion Ring Kit on VG SystemsNuclear Medicine · 43753
- Service Note 43758_1 Jul/07 Infinia Cover Screws now packed inside the installation kitNuclear Medicine · 43758
- Ventri Troubleshooting DIB ADAM GCU Test points, Fuse and LED functionsNuclear Medicine
- Need part number for Infinia Table new Flexible Couplings which are replacing the existing ones to ensure better robustnessNuclear Medicine
- Xeleris 2.0 reports ectb_oc_tmp license problems during Xeleris Licenses Check at start up.Nuclear Medicine
- Need alternate part number for Millennium Table Lateral axis Lead Screw MEC000022.Nuclear Medicine
- How to Backup QPS/QGS Customization on Xeleris 1.1Nuclear Medicine
- When displaying data to Workspace, Getting an Error Message Pop Up with Xeleris 2.0Nuclear Medicine
- Genieacq 4.0 software, some patients not showing transferred that were transferred.Nuclear Medicine
- Ventri system, no counts or image on detector when setup for acquisition.Nuclear Medicine
- Noise during Table Longitudinal motion on Millennium 3-axis table.Nuclear Medicine
- Infinia Unable to move any motions, message "Cover switch Active"Nuclear Medicine
- What do I need to backup and restore when formatting the patient partition on a Polestar (Starcam), Maxxus, or Optima StarcamNuclear Medicine
- What is the Product Security Database and how do I find itNuclear Medicine
- Service Tool - Need part number for NEMA Test Resolution (Linearity) slit phantomNuclear Medicine
- What is a Manufacturer Disclosure Statement for Medical Device Security and where to I find itNuclear Medicine
- CSE detctor shows hot spots in center (or corner) of all PMT tubes on low count studiesNuclear Medicine
- Can not change line spacing or font size of header on hardcopyNuclear Medicine
- Xeleris Default print template cannot be deletedNuclear Medicine
- Xeleris (Entegra) appearance of a button like gray box on the screen.Nuclear Medicine
- Here is a way to backup and restore the Lan-Edit network configuration on the VG or Varicam system.Nuclear Medicine
- Part number required for covers used to cover the anchor bolts on front legs of stator assembly of the Infinia GantryNuclear Medicine
- Service Note 43744_1 Aug/07 VG Rotation Gear The CONE DRIVE Gear ASM001086 is available for order as part of the GEAR ADAPTOR KIT SPARE PART 5197869Nuclear Medicine · 5197869, 43744
- FMI 40813 EDI Dual Isotope Dynamic Scan GenieAcq SW Rev 4.5 Upgrade with Patches GA450-05-1, GA450-06-1, GA450-07-0, GA450-08-1, GA450-09-0Nuclear Medicine · 40813
- Service Note 43706_1 Jun/07 Radius Linear Bearing Replacement For SMV i-Series camerasNuclear Medicine · 43706
- When launching QGS/QPS get ARGi message box with choice to Turn Reporting Off or Exit ApplicationNuclear Medicine
- Part number required for rotor crate fans in the Elscint Helix system due to non compliant part being specified.Nuclear Medicine
- The Ventri GCU voltages all show zero volts when reading them from the debugger screen under gantry handler.Nuclear Medicine
- FMI 40810 Hawkeye 4 DAS Light Barrier - Penetration problem and will be implemented according to the screening results of the FMI 40808Nuclear Medicine · 40810, 40808
- Need part number for indexing board used on CDL type gantry systems.Nuclear Medicine
- During rotation for GLEVEL check on a VH system the gantry continues to rotate without finding the zero position.Nuclear Medicine
- How can I use the CD ROM drive to load Genieacq software on the Dell 1300 PC.Nuclear Medicine
- No gantry or table motions with the Remote Control Unit (RCU) after resetting Ventri systemNuclear Medicine
- Intermittent operation of Millennium Table Lateral motion, Error #9Nuclear Medicine
- Infinia Hawkeye CT X-ray to NM registration fails, and is above the acceptable deviationNuclear Medicine
- XFL (Xeleris Floating License) client will not connect to master Xeleris after performing FMI 40806 (M3 to M4 upgrade).Nuclear Medicine · 40806
- Service Note 43700_0 Sep/07 Mechanical Alignments for the i-Series Cameras.Nuclear Medicine · 43700
- Service Note 43730_1 Sep/07 Uniformity Parameters for SMV Cameras.Nuclear Medicine · 43730
- Unable to start Xray Scan or QC, getting message failed to start sequenceNuclear Medicine · 11404, 11411
- VGH RCU enable key intermittent, getting stuck when pressedNuclear Medicine
- Part number required for Infinia CT/NM Hawkeye registration phantom introduced with the 2.5 software releaseNuclear Medicine
- Ventri system, unable to clear Collision (PSD) error.Nuclear Medicine
- How do I add a default gateway from a remote location to a MS Windows based system (Xeleris, Infinia, Ventri)Nuclear Medicine
- How do I use Infinia Gantry Handler Debugger mode to open or close cross barsNuclear Medicine
- Schedule Management Window does not open during Insite configurationNuclear Medicine
- Part number needed for the source cartridges (syringe) used in the X-Ray to NM Hawkeye registration phantomNuclear Medicine
- During Genieacq Load From Cold, Lynx OS Installation Utilities Disk giving "Disk Fault" error.Nuclear Medicine · 212010832