GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 38 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Need guide for measuring power supplies for Nuclear Medicine Systems - Build Standard, Polestar, Optima, Maxxus, MillenniumNuclear Medicine
- Can not complete safety pad testNuclear Medicine
- Missing section of flood.Nuclear Medicine
- Part number is needed for the Infinia Radial Motor DriverNuclear Medicine · 212004100
- I need part numbers for retract rollers/ spring slides which cover vertical opening for lateral motion when in L-mode on VGNuclear Medicine
- Millennium images have blurry data streaking from a Hot areas to the edge of the FOVNuclear Medicine
- Need Xerox Phaser 8500 / 8550 Printer Installation and Product Support InformationNuclear Medicine
- Dicom copy does not work on Powerstation to any dicom databaseNuclear Medicine
- Need Xerox Phaser 8560 Printer Installation and Product Support InformationNuclear Medicine
- Wants to use manual motion correction on Xeleris but no icon exists.Nuclear Medicine
- Xeleris loses its network configuration after Power OnNuclear Medicine
- Need a part number for the ECG signal board in the Genieacq SuperMicro or IBM 205 computer.Nuclear Medicine
- Infinia database To Do List or Data Management List is missing some or all patient scansNuclear Medicine
- Gantry only rotates about 15 degrees in either direction, hear grinding noise when going past the 15 degrees.Nuclear Medicine
- Detector radius characterizing error.Nuclear Medicine
- MG/MPR table drive (brass) nut for Longitudinal, part number 2199952, is not in stockNuclear Medicine · 2199952, 212010832
- Error code E05 on PowerCom UPSNuclear Medicine
- Service Note 43642_0 May/07 DST Angulation Handle ReplacementNuclear Medicine · 43642, 1000265
- How to find software revision and patches on - Infinia?Nuclear Medicine
- Need correct Millennium CSE rectangular detector correct Spatial Phantom placement for X and Y for MG verses MPRNuclear Medicine
- Service Note 43665_2 May/07 NEC 1990SXi Installation Notes for SMV ProductsNuclear Medicine · 43665, 1750199
- Need to know how to delete customer created Xeleris 2.0 review templatesNuclear Medicine
- Part number required for detector PMT optical coupling greaseNuclear Medicine
- When booting Entegra / Xelieris error message application log full occurs.Nuclear Medicine
- During a collimator change the body contour arms opened up and would not close after installing the new set of collimators.Nuclear Medicine
- Need Part number for Hand Controller (HHC) for Millennium MPR/ MPS/ MPT system.Nuclear Medicine
- Hawkeye X-Ray generator Tube Spits (soft arcs) have been detected by monitors (User MessageNuclear Medicine · 02768
- Part number needed for the Infinia 1 RCU cableNuclear Medicine
- Need part number needed for the Infinia 2 RCU cable.Nuclear Medicine
- Xeleris 2.0 application software will not load on system, getting message which says missing Windows (SP2) Service Pack 2Nuclear Medicine
- Service Note 43212_0 Jan/00 Service Information for Dell Precision 610 Genie WorkstationNuclear Medicine · 142447
- Xeleris multi-frame secondary capture (MFSC) data network transfer is slow and sometimes fails.Nuclear Medicine
- Raw Dynamic image data sent from Xeleris to Agfa IMPAX PACs does not window correctly - Images appear dark and washed out.Nuclear Medicine
- FMI 40811 MPR-MPS-MPT Link to VISION or 3rd Partty Workstation, Rev. 1Nuclear Medicine · 40811
- How to resize the Xeleris / Entegra databaseNuclear Medicine
- Screen Saver locks and requires password to get back to applicationNuclear Medicine
- Hole in the flood artifact on Millennium CSE detector (PMT appears to be out)Nuclear Medicine
- Xeleris (Entegra) Contents of local database does not appear.Nuclear Medicine
- Need the catalog number for the UPS that works on the Millennium MPR/MPSNuclear Medicine · 80424
- Part number required for the rubber collision sensor on the edge of the MPR detectorNuclear Medicine · 212004100
- Need part number for off white Dell 1400 keyboardNuclear Medicine
- When using QGS/QPS or ECToolbox error message 'motion correction license missing' is displayedNuclear Medicine
- Service Note 43749_2 Jul/07 Ventri M4 FRU Spair Parts List ReleasedNuclear Medicine · 43749, 143457
- Service Note 43716_2 Jul/07 Xeleris 2 - HP XW6400 PCNuclear Medicine · 5194926, 43716
- Need instructions for routing Ventri cable CBL500170 from Norav ECG unit to connect to cable CBL500171 inside the stator.Nuclear Medicine · 2414306
- VG Acquisition computer will not power up and there is a yellow led flashing on the front of the PC.Nuclear Medicine
- Where do I find documents on the NEMA DICOM standard.Nuclear Medicine
- How to change user interface (AUI) display theme on 4.0, 4.5 softwareNuclear Medicine
- Xeleris workstation will not boot up and displays yellow flashing led on front of CPU.Nuclear Medicine
- Part number is required for the Optima Table Vertical Motor and BrakeNuclear Medicine
- Transfered VG Hawkeye studies with X ray images fails when using "copy" or "copy to new"Nuclear Medicine
- How to copy or delete files from the ENuclear Medicine
- How to determine the size of the hard drive running XT software.Nuclear Medicine
- How to change the password in system running XT softwareNuclear Medicine
- How to find out the existing password on a XT system.Nuclear Medicine
- Intermittent DST & DST-XL over temperature errorsNuclear Medicine
- Need part number for table grease used on a Millenium table during preventative maintenanceNuclear Medicine
- Xeleris Review templates do not run, error window appearsNuclear Medicine
- How to configure or setup FX site specific infoNuclear Medicine
- MPR/MPS COR value keeps increasing over time.Nuclear Medicine
- VG has no keyboard response, tried reboot, hangs at OS/2 window.Nuclear Medicine
- Xeleris application will not launch or boot.Nuclear Medicine
- PDB Base error #508 trying to boot the systemNuclear Medicine
- Icon for CT-PET Volumetrix missing from programs listNuclear Medicine
- Service Note 43728_0 May/07 Codonics Horizon Printers warranty expiration service strategyNuclear Medicine · 43728
- Product Safety Notification 5165107-100_1 Mar06 Potential Mismatch between Patient Name and ImagesNuclear Medicine · 5165107
- System boot stops at ACQ boards initializationNuclear Medicine
- Error Message Detector near edge or outside the range of calibration when go into camera modeNuclear Medicine
- Schedule Management Window does not open during Insite configurationNuclear Medicine
- Infinia 1 Systeem, Fan Beam Collimator Calibration procedure not listed in Service ToolsNuclear Medicine · 13120658
- During bootup of Xeleris / Entegra application the system sticks at META 4 startup and holds there.Nuclear Medicine
- Starcam Polestar Computer console not booting up, no power indication at console, gantry does have power.Nuclear Medicine
- Reading Xeleris pixel data from database failed message.Nuclear Medicine
- Part number required for Infinia P-Scope power cordNuclear Medicine · 212004100
- Service Note 43755_1 Jul/07 Infinia I / Infinia II / Hawkeye 4 SEM to CIB Part Number Compatibility MatrixNuclear Medicine · 43755
- Service Note 43754_1 Jul/07 INFINIA Dolly Caster CollapsedNuclear Medicine · 43754
- Service Note 43751_1 Jul/07 Ventri IPS GroundingNuclear Medicine · 43751
- Service Note 43748_1 Jun/07 Ventri M4 Security Patches Network Vulnerabilities MS07-019 & Windows XP DST, for Ventri M4 Configuration currently at 1.004.040.1Nuclear Medicine · 43748
- Service Note 43745_2 Aug/07 New Spare Parts for Xeleris WorkstationsNuclear Medicine · 43745
- Service Note 43727_1 05/07 New Ventri Collimator Storage CabinetNuclear Medicine · 43727