GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 40 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Have to confirm deletion of each study when deleting multiple studies from the VG acquisition Local Catalog.Nuclear Medicine
- MG-MC-Myosight intermittent operation of the VG lock assembly.Nuclear Medicine
- MG-MC-Myosight changing to cardiac position fails with Radial 2 errorNuclear Medicine
- Will not acquire QC or any scans, getting error on Infinia software, failed to start sequence.Nuclear Medicine
- Need the Product Datasheet for Optima NXNuclear Medicine · 212010832
- Need Product Datasheet for Starcam XRTNuclear Medicine · 212010832
- Need Starcam, Polestar, Optima, Maxxus Command Reference ListNuclear Medicine
- Processing and data transfers slow down 10 min after reboot.Nuclear Medicine
- Immediately after seeing the IGEMS on Starcam polestar boot up, an error message occurs that indicates Register at FF should be 44Nuclear Medicine
- Need troubleshooting for Infinia error 144 velocity test axis 8 Table Longitude motionNuclear Medicine
- Millennium Myosight Table will not move in or out and(longitudinal) will not release brake with either button.Nuclear Medicine
- Monitor image display color incorrect, distorted or missing part of image screen.Nuclear Medicine
- Genieacq will not boot after loading patches.Nuclear Medicine
- Genieacq system with X detector (XRT/XCT) getting detector power supply error when setting up for acquisitions.Nuclear Medicine
- Millennium MG system goes into Collision whenever radial 2 motion attempted.Nuclear Medicine
- Genieacq no response from Keyboard.Nuclear Medicine
- System gives Error 27 Gantry Mode Mismatch after rebooting or GRESETNuclear Medicine
- Infinia new installation, Table motions not functioning.Nuclear Medicine
- Need part number for Infinia / VG table pedal switchNuclear Medicine
- Need to know Xpert Dicom Communication Settings (AEtitle, Port Number)Nuclear Medicine
- Need part number for Millennium Collimator sensor plate contact boardNuclear Medicine
- During Full EDI upgrade, or any time computer is replaced the motion controller program is lost..Nuclear Medicine · 212010832
- Insite checkout failure, Telnet timeout - “Getting a telnet session to the product” and that is where it will eventually time out and fail.Nuclear Medicine
- Service Tool - Need Dial Indicator for Backlash AdjustmentNuclear Medicine
- How do I back up the Emory Cardiac Toolbox NRP reporting package data on XelerisNuclear Medicine
- Dicom device does not show when doing Pat Dir operationNuclear Medicine
- The MG Detector 1 24vdc LED is out on the gantry power supply board and getting intermittent collisions.Nuclear Medicine
- VG/Varicam Jaszczak phantom images have ring artifacts.Nuclear Medicine
- How to acquire Polestar Uniformity Correction for more than 100,000,000 countsNuclear Medicine
- How to view DICOM printer errorsNuclear Medicine
- MPR/MPS loses gantry position calibration with Pinhole collimator mountedNuclear Medicine
- When setting DynamicSCScreenBW or DynamicSCScreenColor as default on "print dialog", Aladdin Editor can't open then Xeleris restartsNuclear Medicine
- Need part number for Ventri Table Longitudinal Motion DriverNuclear Medicine · 5150729
- Part Number ASM000533 given in MPR/MPS service manual for Right Cover shows as not orderableNuclear Medicine
- What are the Maxxus handheld controller IC assignments on the DP1 board?Nuclear Medicine
- Service Note 43209_0 Jun/00 MPR/MPS Gantry Arm Collision Cover AssembliesNuclear Medicine · 43209
- Service Note 43756_2 Jul/08 Optional Gamatronics PowerPlus SA UPS and Vendor ListNuclear Medicine · 43756
- Xeleris application seems to be shifted on the screen causing problems activating certain processing protocols etc.Nuclear Medicine
- I need the PowerPlus User Guide for the new Gamatronic PowerPlus SA UPS used on the Infinia product.Nuclear Medicine
- Fetching patient data from the Infinia or Ventri database using the Xeleris processing station Query Retrieve is not supportedNuclear Medicine
- How to configure the ACI board optionNuclear Medicine
- Part Needed for COR Jig used on Ventri and Infinia for COR BUILD and COR TESTNuclear Medicine · 212010832
- How to calibrate the AOB board for a Starcam PolestarNuclear Medicine
- Infinia II acquisition computer hangs with a blue screen and config_initialization_failed error while booting.Nuclear Medicine
- Who do we call for Start-up and Service on the Gamatronics on-line UPS Series and the new H2505ZE PowerPlus SA UPS.Nuclear Medicine
- Xeleris will not boot into application after new licenses generated, message Not a valid license file.Nuclear Medicine
- Optima COR values are above limits.Nuclear Medicine
- Need part number for the coupler in the arm connecting angulation motor to gearbox in the DS iSeriesNuclear Medicine
- Service Note 43760_1 Oct/07 Xeleris Software Updates (Version 2.0551) for Xeleris 2Nuclear Medicine · 43760
- Service Note 43729_1 Oct/07 VPL and PV-Wave Install GuideNuclear Medicine · 43729, 1007432
- MG/Myosight/MC system in collision and unable to boot genieacq or acquire on one or both detectors.Nuclear Medicine
- Ventri/ I need the part nubmer for the GE logo on the front cover of the gantryNuclear Medicine
- New printer which is add in Xeleris configuration utility is not appearing in the Workspace Print DialogNuclear Medicine
- Unable to read Entegra dicom cd on the Xeleris.Nuclear Medicine
- Infinia collimator and PSD cover names do not cross reference from Elscient to GE part numbersNuclear Medicine
- Infinia Gantry Missed Target error 143 on axis 9 table height motionNuclear Medicine
- Need to know part numbers for materials needed for detector recoupling.Nuclear Medicine
- Infinia gantry error 118 ILLEGAL AXIS NUMBER OR AXIS DISABLEDNuclear Medicine
- Polestar XC, XR, Maxxus Detector Controller Power Supply 46-288052G5 (T3415TL) Troubleshooting HintsNuclear Medicine
- Infinia table stretcher was giving "Obstructed track" error during scanNuclear Medicine
- Infinia Hawkeye scan extended pause during the transition from nuclear emission to CT transmissionNuclear Medicine
- Infinia Center of Rotation (COR) calibration value is out of specification, above limitNuclear Medicine
- LNX workstation The part number for Dell Precision 330 (PN 2340856) for Entegra will work on LNX WorkstationNuclear Medicine · 2340856, 212007816
- Infinia / VG Table up down noisy with motionNuclear Medicine
- Sevice Note 43119_0 Jan/99 Modification to Millenium Patient Table CastersNuclear Medicine
- See patients on camera's database from Powerstation that do not transfer.Nuclear Medicine
- Infinia Hawkey 4 Scan erors in log indicating that there has been a HIB communication error.Nuclear Medicine
- Need part number for Isolation transformer used on Xeleris and Entegra systemsNuclear Medicine
- Xeleris Monitor is blurry, has ghost behind icon'sNuclear Medicine
- How do we activate the Maintenance Bypass on a Gamatronics MPS series 3 phase 10 KVA UPS without disconnecting power from the load?Nuclear Medicine
- Need the catalog number for the new Gamatronic PowerPlus SA UPS that comes with the Infinia cameraNuclear Medicine
- I need the part number for the MG roll motor assemblyNuclear Medicine
- Service Note 43761_2 Feb/07 Xeleris 2 and 3 USB HASP ID Transfer ToolNuclear Medicine · 43761
- Service Note 43764_1 Oct/07 Infinia DST Daylight Savings Time Patch for Windows 2000Nuclear Medicine
- Service Note 43765_1 Oct/07 Infinia DST Daylight Savings Time patch for Windows XPNuclear Medicine
- How to configure Genieacq Acquisiton system for VPN Broadband Insite connection.Nuclear Medicine
- Need information on Millennium 2168930 Can Handset Buss board LEDs, connectors and jumpersNuclear Medicine · 2168930
- Need the part number for replacement Infinia collimators for LEHR (45) for Detector and 2Nuclear Medicine
- Infinia image quality issue - energy peak shiftedNuclear Medicine
- Writing to CD getting message Cannot attach to driver CDUDF.SYS.Nuclear Medicine