GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 21 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Change to L mode paused, need to press set to continue.Nuclear Medicine
- NM Flood showes black holeNuclear Medicine · 5376374
- Static ACQ has strange PHA and STA when installation.Nuclear Medicine
- Need part number for Millennium table up/down motorNuclear Medicine
- Need part number for VG collimator lock microswitchNuclear Medicine
- Discovery NM/CT 670:During installationNuclear Medicine
- During Hawkeye X-ray (or any Cardiac) scan as rotation starts, motion intermittently stops, GDU showed "Press Resume to continue"Nuclear Medicine · 113845
- VG table can't move back and forward, gantry error 167 MAXIMUM DAC COMMAND,AXIS=BCK/FWDNuclear Medicine
- After replacing workstation, there is no network connectivity, whatever parameters are changedNuclear Medicine
- Infinia gantry Rotation motion, using Pamel diagnostics, move slow in only one direction.Nuclear Medicine
- Body Contour function is disabled message, Body Contour test failed message on GDU during starupNuclear Medicine · 02704
- Damage to the Ventri / 530c Prone Support Hand grippersNuclear Medicine
- Discovery NM 530c/570cNuclear Medicine
- Infinia VC FDG CODE image scan has no counts, NM TC99M scans are normalNuclear Medicine
- Norav No ECG gate Signal - Acquisition screen no ECG signal detected.Nuclear Medicine
- Need a part number for the ventri table retractor cable.Nuclear Medicine
- Table lock PIN's steel wheel was broken and the table couldn't be moved smoothly asid into the anchor plate during collimator exchange procedure.Nuclear Medicine
- Where to find total Hawkeye 4 CT Exposure time is given in seconds.Nuclear Medicine
- What is the thickness of the detectors shielding?Nuclear Medicine
- What is the weight of the decoy collimator on Infinia?Nuclear Medicine
- What is the tolerance for COR test acquired outside of central point of FOV?Nuclear Medicine
- Service Note 43914_1 Jul/2011Infinia II GP & Hawkeye 4 SP2 Cumulative Patch Ver. 2.105.030.10Nuclear Medicine
- Service Note 43906_1Jun/2011Infinia Rotation Motor, Coupling and Gear ReplacementNuclear Medicine
- Service Note 43900_1 Feb/2011Infinia Collimator Cart Translated Safety LabelsNuclear Medicine
- Service Note 43872_1 May/2011 Measuring Floor FlatnessNuclear Medicine
- During Patients CODE FDG scan in Infinia VC system, no image displayNuclear Medicine
- VGH system -With CODE- will not acquire getting Front End Initialization errorNuclear Medicine · 100008553
- VG Gantry Error 32 on Rotation Zero Switch Detected Misplaced during rotationNuclear Medicine
- Coincidence rate drops to 0 intermittently during VG CODE FDG scanNuclear Medicine
- VG/Infinia table cannot retract after it has been fully extended with or without a patient on it.Nuclear Medicine
- Infinia unable to scan get error FAILED TO START SEQUENCENuclear Medicine · 11411
- FDG CoDe acquistion has single rate, but has no counts rateNuclear Medicine
- VG/VH reported ERROR #46 on gantry displayNuclear Medicine
- Patient table linear motion does not move when starting acquisition.Nuclear Medicine
- What is the Registration limits difference between Hawkeye 1 and Hawkeye 4?Nuclear Medicine
- Radial 1 Brake Error 171 after a gantry resetNuclear Medicine
- What is the right P/N for the HEMIT Tank on the Brightspeed installed Discovery NM/CT 670Nuclear Medicine
- Greset or collimator exchange, gantry GDU prompts "PSD test", press CB2 PSD, no response (no relay sound).Nuclear Medicine
- When configuring HE4 newtork adapter getting message - IP address 192.168.251.192 you have entered for this network adapter is already assignedNuclear Medicine
- VGH system will not acquire getting Front End Initialization errorNuclear Medicine · 100008553
- Need a part number for Glide TapeNuclear Medicine
- FMI 40831_1 Aug/11 Discovery NM/CT 670 Labels AttachmentNuclear Medicine · 40831
- Discovery NM 530c/570cNuclear Medicine · 43919
- KANM Migration Test IssueNuclear Medicine · 11760
- During rotation, intermittent gantry error 120 collimator unlock occurs randomly on either detector.Nuclear Medicine
- Gantry Error 157, GDU show Error 157 CLC OVERCURRENT axis = $Nuclear Medicine
- Discovery 670 wholebody scan image shiftNuclear Medicine
- After changing Language Support to the Keyboard, login password is not working after reboot.Nuclear Medicine
- Norav No ECG gate Signal - Acquisition screen no ECG signal detected.Nuclear Medicine
- Unable to create Extended database on Z400 Xeleris 3Nuclear Medicine
- Xeleris 3 Extended Database option will not reduce the existing database sizeNuclear Medicine
- Xeleris 3 when archiveing to Sony MOD, Write Now button not activeNuclear Medicine
- After camera upgrade to software version 38_4 SW, Xeleris does not process EFB (Evolution) data.Nuclear Medicine
- Service Note 43873_r1 Jul/11 SPECT Phantom QC for ACR on Millennium SystemsNuclear Medicine · 43873
- FMI 40833_1 GenieAcq PR Server License ExtensionNuclear Medicine · 40833
- Service Note 43940 SEP/11 D630/D670 Precautions to be taken when lifting Detectors Lead CoversNuclear Medicine · 43940
- Service Note 43924_1 Sept/11 Introducing NM Digitized PM ChecklistsNuclear Medicine · 43924
- What are Infinia Hawkeye 4 X-Ray generator specification?Nuclear Medicine
- Infinia after a Greset getting an Error # 172 DAC test failed to initialize 5 V sense messageNuclear Medicine
- Need the part number for the Ventri table front cover.Nuclear Medicine · 5183812
- VG has no image and no counts detected during acquisitionNuclear Medicine
- During automatic motion of the table linear (Axis 8) the table would move several inches and then display velocity Error 144.Nuclear Medicine
- Millennium MPR static images show detector with strip block of no counts from moduleNuclear Medicine
- after gantry power on,automatic reboot again,then display all axial position wrongNuclear Medicine
- Infinia 1" Detector showing PMT cold spot (hole) in flood imageNuclear Medicine · 11279
- Ventri will not setup for scan getting failed to start sequence error.Nuclear Medicine
- CoDe Best Width calibration results always failed during coincidence calibration.Nuclear Medicine
- Error #148 happens intermittently when Radial axis is beginning to moveNuclear Medicine
- Need EMEA part info for X-ray Tube Lifting CraneNuclear Medicine
- Xeleris fails to boot up, message unable to load i8042prtNuclear Medicine
- Intermittent gantry errors #47, #103, #120Nuclear Medicine
- Discovery NM 530c/570cNuclear Medicine
- Service Note 43936_1 SEP/11 Discovery 630 and Discovery NM CT 670 SW version 38_4 release notesNuclear Medicine · 43936
- Service Note 43916_1 Xeleris MS Security Patch MS11-020 for Xeleris 3 and 2.x with Service Pack 3 (SP3)Nuclear Medicine · 43916
- Need part number for Pinhole Collimator insert locking nutNuclear Medicine
- Hawkeye X-Ray QC or Patient images ring artifactsNuclear Medicine
- Gantry in L mode, noisy gantry rotation gantry and generates 167 errors on axis 7Nuclear Medicine
- Millennium MG Gantry only have Rotation motion, all other motions fail to move with handset or initialize.Nuclear Medicine
- Discovery NM 750b (MBI)Nuclear Medicine
- Infinia failing Xray Daily QC results, scout image abnormal, also table in/out made strange crunching noise.Nuclear Medicine