During Hawkeye X-ray (or any Cardiac) scan as rotation starts, motion intermittently stops, GDU showed "Press Resume to…
During Hawkeye X-ray (or any Cardiac) scan as rotation starts, motion intermittently stops, GDU showed "Press Resume to continue"
Symptom
During Hawkeye X-ray (or any Cardiac) scan as rotation starts, motion intermittently stops, GDU showed "Press Resume to continue" During Hawkeye X-ray (or any Cardiac) scan as rotation starts, motion intermittently stops, GDU showed "Press Resume to continue motion intermittently stops during CT acquisition, GDU showed "Press Resume to continue The Consol displays a message saying "Acquisition has been paused". GDU displays "Press [GO] to resume , Press [OK] to stop". Error logs indicates an RCU key has been pressed , no other errors. Started as intermittent issue and became almost permanent after few weeks. Rotating at lower speeds would allow rotation.
Error message
Infinia GDU Message: X-RAY ON Press [GO] to Resume, GantryServer warning - RCU has been pressed Error Logs: [email protected] : 15:58:53 WARNING=Warning in GantryServer d:\tacq\su\src\cpp\gantry\server\translategantrytohost.cpp(320) Got warning from gantry: !WR(1,7167) 15:58:53 Received from Gantry : !SP(1002) 15:58:53 RCU has been pressed [email protected]: 15:58:52 GDU message:X-RAY ON 15:58:53 GDU message:Press [GO] to Resume Press [OK] to stop ! Syslog.csv may show: Task:SCAN Activity:PAUSE Parameters:TASK_UID=1.2.840.113845.11.1000000001804980978.20110227095758.1855469_REST-1|REASON=RCU has been pressed Task:SCAN Activity:RESUME Parameters:TASK_UID=1.2.840.113845.11.1000000001804980978.20110227095758.1855469_REST-1|REASON=Gantry server sent continue acquisition after pause
Applies to
- Models
- Infinia
- Product
- Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
- Component
- *Gantry Gantry Gantry 5176430 Infinia Elmo Tuba Rotation Driver 5176430 Infinia Elmo Tuba Rotation Driver
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.