GE Healthcare · Nuclear MedicineInfinia100008553
VGH system will not acquire getting Front End Initialization error
Symptom
VGH system will not acquire getting Front End Initialization error VGH system will not acquire getting Front End Initialization error.
Error message
Failed to initialize Front End (FE) Folllowing Example Only: Error on file error.log (apex\log\d): *** ERROR: in QfsSetPortAdr: SetPortAdr failed to set port <e05>, error <5> *** ERROR: in QfsSetControl: Failed to set control <EVENT_DETECTOR> *** ERROR: in QfsLoadContPorts: failed to load control ports *** ERROR: in QfsGetFile: Failed to read FEPAR file <5> commerr.log (acqdb\fe\error), after FE Diagnostic: Starting test fecomm 04/09/10 21:51:10 ERROR - Write port failed - port = e05 error = 504/09/10 21:51:10 ERROR - FRU - DOC 2 board - write error to DOC04/09/10 21:51:10 ERROR - COMMUNICATION TEST FAILED !!04/09/10 21:51:10 *** warnings:04/09/10 21:51:10 *** NO_RESPONE: 1204/09/10 21:51:10 *** CORRECT_DATA: 004/09/10 21:51:10 *** CRC_ERROR: 004/09/10 21:51:10 *** VIOLATION_ERROR: 004/09/10 21:51:10 *** SEMAPHORE_ERR: 004/09/10 21:51:10 *** TIMEOUT_ERR: 004/09/10 21:51:10 *** ENTER_CRIT_SEC_ERR: 004/09/10 21:51:10 *** EXIT_CRIT_SEC_ERR: 004/09/10 21:51:10 *** OTHERS: 004/09/10 21:51:10 *** TOTAL: 1204/09/10 21:51:10 *** End Test senseheat results: *** SENSORS TEST REPORT *** PORT HEAD 1 HEAD 2 --------------------------------------------- DOC_sens_1 31.176 26.144 DOC_sens_2 26.998
Applies to
- Models
- Infinia
- Product
- VGH VG and VG Hawkey and Varicam
- Component
- *Detector (Imaging Detector) *Detector (Imaging Detector) *Detector (Imaging Detector)
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.