The Medrad HD NV Coil may demonstrate intermittent Open Circuit Driver faults during scanning.

Symptom

The Medrad HD NV Coil may demonstrate intermittent Open Circuit Driver faults during scanning See long description. Error code 2252301. SMILe 8/23/2005 This information is Property of GE - For GE Service Personnel Only. Disclosure to Third Parties Prohibited. Subject: MR SMILe: Updated! Signa HD 1.5T NV Coil Intermittent Driver Faults Effectivity: All Signa Excite HD (12.x) systems with the 1.5T HD NV Coil by Medrad (M3087JJ, 5117092-2). This coil can be identified as the only 1.5T neurovascular coil with the new HD system connector. Problem Description: The Medrad HD NV Coil may demonstrate intermittent open circuit driver faults (error code 2252301) during scanning. Investigation has indicated that this failure is caused by a combination of system DC fault specifications and gradient-induced signals on the coil DC lines. The frequency of failure will vary by site (many sites showing no failures at all) due to several site-varying parameters that impact bias currents (cable length, etc.) Corrective Action: Install 12.0 M4 Patch 10 (patch_12.0_M4_10-PA-2.i386.rpm). This patch modifies the bias voltages and open circuit fault values to prevent driver faults. After patch installation all HD NV coil names must be removed from the site list and added back in using the config file manager. This must be done for the changes provided by the patch to take effect. See the readme note included with the patch for details. Thank you! Kyle Zeller MR Product Quality GE Medical Systems SMILe's and Service Notes are copyright (c) to General Electric Company Inc with all rights reserved. SMILe's and Service Notes issued by GE Medical Systems are proprietary to GE Medical Systems. Disclosure to persons not employed by GE Medical Systems or not in possession of a Advanced Service Agreement with GE Medical Systems is prohibited. Author Kyle Zeller SME Scott Allsop

Error message

2252301 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCDx Channel x of y, counting from 1 Value x mA Limit y mA See Long Description for Extended Error 2252301 MRI_GB_OW0 NSP SCP:DCB 816 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 (or MCD2) Channel 1 of 16, counting from 1 Value: 2 mA Limit: 298 mA Mask of failed channels: 0x1 Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B-> Extended Error: This fault was detected by the Driver Module. An open circuit fault occurs when the actual value is less than the pre-defined limit. Check system cables, connectors, coils and configurations. Re-seat all coil connectors. The mask of all failed channels indicates additional channels with the same fault - convert the hex number to a bitmap to decipher the mask, with channel 1 indicated by the least significant bit and channel 16 indicated by the most significant bit. For example, a mask of 0x3c converts to 0011 1100, meaning channels 3, 4, 5, and 6 all experienced the same failure. The key at the bottom of the error message shows the MC driver bias channels provided by the Driver Module used with each mult

Applies to

Models
Signa, Excite
Product
Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
Software
15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
Component
5117092-3 1.5T Medrad HD NV Array Coil Cable 5117092-3 1.5T Medrad HD NV Array Coil Cable
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.