Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.Unable to Scan with RF Air Temperature Fau…
Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.Unable to Scan with RF Air Temperature Faults
Symptom
Unable to Scan with RF Air Temperature Faults
Error message
2261733 Heat Exchanger Cabinet (HEC) detected customer coolant temperature is out of specification (too high). See Long Description. 2261733 NSP SCP:CoolingHWO 2836 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 Heat Exchanger Cabinet (HEC) detected customer coolant temperature is out of specification (too high). Please verify that the facility coolant temperature and flow is within specification. This alarm will not stop scanning-> Extended Error: Heat Exchanger Cabinet (HEC) detected customer coolant temperature is out of specification (too high). Please verify that the facility coolant temperature and flow is within specification. %b 2268905 RF air temperature fault detected. Scanning will be inhibited until the RF air temperature matches expected. See Long Description 2268905 NSP SCP:SriCanHWO 1998 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: Unknown Coil: Unknown Scan: -1/-1 RF air temperature fault detected. Scanning will be inhibited until the RF air temperature matches expected Temperature difference: 107 0.1 degrees C Tolerance: 30 0.1 degrees C-> Exte
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.