GE X-ray R&F — field troubleshooting
3,432 field-service issues · page 7 of 43
Symptom, error message and equipment context for each GE X-ray R&F issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- P500D No auto-collimationX-ray R&F · 600500
- RFX/SFX and Legacy Z-Rail repair procedureX-ray R&F
- System won't auto collimate larger than 8x11 field size to table buckyX-ray R&F
- Unable to restore Protocol backup to new style console 5329293X-ray R&F · 5329293
- overhead collimator blades oscillating and sid display is jumping around to different numbersX-ray R&F
- XRAPPS DRS - Unable to acquire new study.X-ray R&F
- Exposure inhibit with message door open close the doorX-ray R&F
- QAP fails to launch and connection to 192.168.1.1 failure message is displayedX-ray R&F
- Modify cdwrite.cmd script for compatibility with SATA optical drivesX-ray R&F
- Collimator Lamp not workingX-ray R&F
- Contact PACS Administrator for room configuration checkX-ray R&F · 800040
- Collimator fails to complete boot sequenceX-ray R&F · 600513
- XRd2X, Def8000, AMX700 Worklist is not populating.X-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- What meter is used for collimator light field output testingX-ray R&F
- System can't exposal and fluoro in any model and exposure indicators were not light when we push buttonX-ray R&F
- no Auto positioning and collimator not working CB8 tripped on the TSL board in the OTSX-ray R&F
- What is the maximum weight limit that can be put on the tethered Detector?X-ray R&F
- What do the Z error codes mean on the Eclipse collimator?X-ray R&F
- Error 3501 on power upX-ray R&F
- Precision 500D Aretha Long and Vert Can Ampifier Node Guarding ErrorsX-ray R&F · 1090002, 1090004
- E stop message on consoleX-ray R&F
- FE replaced the Siemens CollimatorX-ray R&F · 2266999
- The user-added annotation size is too small when displayed on PACS or printed on Laser Film.X-ray R&F
- Revolution XRd Unit will error 6C00 and 6D00 in digital mode after first exposure.X-ray R&F
- PROTEUS Table LimitsX-ray R&F
- Computer red light blinks and beeps 4 timesX-ray R&F
- HP6400 communication via ethernet interface fail.X-ray R&F · 5198015
- Some users are unable to view DICOM images using the DICOM Viewer that is included on the CD/DVD archive media.X-ray R&F
- image pasting misaligned, pixel stitching is not acurate and the images are shifted laterally, a manual repaste is required.X-ray R&F
- Persisted Worklist Query Failure for DR-F system with V5 and V6 software.X-ray R&F
- Customers may feel that when images are printed on film, the Patient Info annotations or textX-ray R&F
- Brivo DR-FX-ray R&F
- PDU POWER FAILURES (LOSING PHASE)X-ray R&F
- The default MWL timeout in DR-F system is 15 seconds, but in some site we need take more than 50X-ray R&F
- CF CALIBRATION INSTRUCTION FOR V7 UPDATEX-ray R&F
- How to connect the MPH A5 PS2 part number 2264833X-ray R&F · 2264833
- Patient examination does not transfer to PACSX-ray R&F
- edit network-cfg.xml file see attached instructionsX-ray R&F
- Delay the power ON of the Prestige SI Table from the Generator power ONX-ray R&F
- FMI 10841 Implementation Issue:MUST use Teleservice 2.3 delivered with FMI kit and upgrade from 1.3x to 1.4x , then 1.5b.X-ray R&F
- PROTEUS What needs to be done when the KV Control Board in a Proteus JEDI Generator is replaced?X-ray R&F
- Definium 5000 Magic PC is booting slow, generator communication error.X-ray R&F · 3600024
- Silhouette HFX-ray R&F
- P500D Insite checkout fails.X-ray R&F
- Noise coming from inside the generatorX-ray R&F
- Getting error SYSTEM RUNNING IN DEGRADED MODE.X-ray R&F
- Error 4159 Filament drive failureX-ray R&F
- Compression power assist drives down by itselfX-ray R&F
- VIC - Light Bias Error 4727X-ray R&F
- Def8000 OTS UIF display flips the wrong way when X-ray tube is angulated 90 degrees.X-ray R&F
- Bad voltages on detector power supplyX-ray R&F
- Intermittent error 3800105 No Sensor FeedbackX-ray R&F · 3800105
- Def8000, XRd2X Several sites experienced a problem where after an acquisition, only the thumbnail images are displayed; full size images will not display.X-ray R&F
- How do you set the collimator LAMP ON TIME?X-ray R&F
- Def8000 Detector temperatureX-ray R&F · 691795, 000000
- HP workstation will not power up, red light on the front and 3 beeps, then a pause, then 3 beeps again.X-ray R&F
- X-ray R&F · 162122X-ray R&F
- Bad pixels may show up on wallstand detector images right after a load from cold of the Magic PCX-ray R&F
- The firmware on the detector is the same as the firmware being downloaded.X-ray R&F
- When “Restart TVA” Selected, TVA panel continues to display “Awaiting Connection”X-ray R&F
- Daylight Savings Time on the Gipeto (XRd)X-ray R&F
- Tube Spits or HV Inverter OverheatX-ray R&F · 3604009
- error code 3601277 ,right cell does not stop.X-ray R&F · 3601277
- Acquired images have large white borderX-ray R&F
- autopositioning don't work after manualy moving the OTSX-ray R&F
- Modify cdwrite.cmd script for compatibility with SATA optical drivesX-ray R&F
- OTS cable harness support is broken - cable hanging downX-ray R&F
- P500D IUI Console Motherboard CPU looses time and date when the system is powered off.X-ray R&F
- AMX 700 will not read service keyX-ray R&F
- AMX4 AMX4+ Charge Fault Error 104X-ray R&F
- AMX 4 - Error 326 Battery FaultX-ray R&F
- AMX4+ new Orion MX75 TH11 X-Ray tube and controller board compatibilityX-ray R&F
- When software is upgraded to latest version, there will be different requirements for FRUs.X-ray R&F
- Auto-shutter may fail sometimes.X-ray R&F
- only the longditudinal locks are releasingX-ray R&F