GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 29 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Service Note 43633_1 Feb/06 Motion II ver. 2.0 Software for VG SystemsNuclear Medicine
- Service Note 43632_1 Feb/06 VG Service Pack # 5169169 Q3 ver 2.0Nuclear Medicine · 5169169, 43632
- Service Note 43420_0 Feb/03 Acquisition Console Monitor Tapping SchematicsNuclear Medicine · 43420, 43385
- Service Note 43419_2 Sep/06 DS7/DSX/DHD Dialog Console UpgradeNuclear Medicine · 43385
- Service Note 43418_0 Feb/03 Rotor Drive Shaft Inspection DHD/DS7/DSX camerasNuclear Medicine · 43418, 1007385
- Service Note 43417_0 Mar/03 Scintibed Linear Rail ReplacementNuclear Medicine · 43417
- Service Note 43416_0 Jun/03 MVME162 CPU Board RetrofitNuclear Medicine · 43416, 68030
- Service Note 43415_0 Jan/03 DSX/DST Safety Pad AttachmentsNuclear Medicine · 43415
- Service Note 43409_0 Jan/03 17’’ Monitor Upgrade, The 17’’ monitor [P/N 1750199] is obsolete and needs to be replacedNuclear Medicine · 1750199, 43409
- Part number is required for the RCU on the Infinia 1 systemsNuclear Medicine
- Part number required for the Infinia II / HE4 RCUNuclear Medicine
- Service Note 43422_2 Nov/05 Floor plate grounding upgradeNuclear Medicine · 43422
- XC/XR detector Energy calibration fails saying the adjustment is too far out of range.Nuclear Medicine
- Service Note 43408_0 Jan/03 Gantry lateral motor assembly verification & adjustment procedureNuclear Medicine · 43408
- Xeleris will not boot into application after Software Load.Nuclear Medicine
- How to get into VG Panel without a service activatorNuclear Medicine
- MG Under Genieacq AUI PPM control - when going from home to collimator exchange, going from collimator exchange to home, when changing from cardiac to whole body, and when changing from whole body to…Nuclear Medicine
- MG detector that was exhibiting extremely tubey image artifact, both corrected (with ECOR and LINCOR) and uncorrected with only PMT appliedNuclear Medicine
- Blank and no counts in some or all Gated Cardiac SPECT acquisition image framesNuclear Medicine
- Xeleris does not boot, video screen is blank.Nuclear Medicine
- Infinia Hawkeye processed data that exhibits a grainy over-filtered study, only on studies that are manually transferred to Xeleris 1.0 and processed with Volumetrix to check registration.Nuclear Medicine
- Power quality troubleshooting from the A1 to the input transformer on the Infinia.Nuclear Medicine
- Infinia will not go into L-Mode, as when it goes to move Laterally it gives Gantry Error #167 Max DAC Command on the Lateral axisNuclear Medicine
- How to make mains power wiring connections from the Gamatronic 10KVA UPS to the Infinia Mains Transformer for 208 V Delta Topology Configuration (USA)Nuclear Medicine
- Part number required for the Spring Slide Roller Cover Assemblies on the front of the Infinia gantry rotor.Nuclear Medicine
- Need to know if the Gamatronic UPS Model 10KVA is CSA and ANSI/UL listed for use in Canada and the US.Nuclear Medicine
- Need Infinia Saxophone (Elmo Motion Controller) rotation driver user manualNuclear Medicine
- What are the Infinia Saxophone (Elmo Motion Controller) Rotation Driver 7-segment Display Codes?Nuclear Medicine
- Service Note 43407_0 Jan/03 Consoles and New Line Power Supply UpgradesNuclear Medicine · 43407
- Service Note 43404_0 Dec/02 Pinhole Safety Device Test ProcedureNuclear Medicine · 43404, 735552
- Service Note 43402_0 Aug/03 SMV AAQ/DAQ Card Rack ModificationNuclear Medicine · 43402
- Service Note 43356_0 Feb/06 Infinia NEMA Phantom Kit.Nuclear Medicine · 43356
- Service Note 43490_3 Oct/06 DSTi and DSi Collimator Lock AdjustmentsNuclear Medicine
- Part number required for Millennium Table location plate (Puck) and anchorsNuclear Medicine
- Infinia Error #83 Drivers voltage testNuclear Medicine
- How to Troubleshoot MG Collision and E-Stop safety circuitNuclear Medicine
- How to shutdown or restart the Genieacq when the AUI is locked up, frozen and not respondingNuclear Medicine
- How to shutdown or restart the Genieacq when the AUI is locked up, frozen and not respondingNuclear Medicine
- No Counts on CSE Detector, reports High Voltage ErrorNuclear Medicine
- System will not boot Genieacq, takes login and password, blanks out screen briefly then immediately comes back to login screen.Nuclear Medicine · 212004014
- System will not boot Genieacq, takes login and password, blanks out screen briefly then immediately comes back to login screen.Nuclear Medicine · 212004014
- I have an Xeleris that shows all remote databases (In Xeleris config) with Red "X"'s next to them (and "ERR") - however they do work correctly.Nuclear Medicine
- RADIAL 1 drive goes maximum speed until MAX DAC error #167 is reachedNuclear Medicine
- Polestar Non IAP system - No display on monitor (A/N or Image), computer booting normallyNuclear Medicine
- GENIE Solaris will not boot up, stops at Database (db) check. (DB corrupted).Nuclear Medicine
- When performing a software Load From Cold (LFC) on IBACQ Software Version 2.9 getting error regarding not enough disk space when partitioning hard drive.Nuclear Medicine
- How to backup and restore site specific information on AIX powerstationNuclear Medicine
- Hawkeye X-Ray Detector Pin Alignment (X-Ray Center of Rotation) Calibration fails with unacceptable Detectors Shift Result valuesNuclear Medicine
- Genieacq Dell 1400SC will not boot AUI but would fail with error PR server License failing to validateNuclear Medicine
- Service Note 43456_0 Mar/06 DST and DST-XL Quad Power Supply Replacement Astec replaced by Omega ModelNuclear Medicine · 43456
- Part number required for Infinia Cross Bar (Body Contour) CED PSD switch assemblyNuclear Medicine
- Part number required for the Maxxus table longitudinal drive nutNuclear Medicine
- How to restore examples database on AIX PowerstationNuclear Medicine
- Part number required for Starcam XR/XC/AC Detector CableNuclear Medicine
- New mechanical lubrication grease replacing all previously used grease for SMV CamerasNuclear Medicine
- VG gantry rotation direction is unreliable, when commanded to go clockwise randomly goes other direction with no error in panelNuclear Medicine
- Infinia Flood image Crop Circle Image ArtifactNuclear Medicine · 100006836
- Processing a QGS/QPS protocol, would stop after several seconds a window opened with messageNuclear Medicine · 65536
- Genieacq IBM 205 PC fails to transfer intermittently or after first dataset.Nuclear Medicine
- Xeleris boots then closes down, message Unable to Open In-BoxNuclear Medicine
- What are the Millennium CSE detector Pixel size calculation based on matrix size and zoom factorsNuclear Medicine
- What is the normal resistance measurement of the PMT tube package in an XR or XC Detector?Nuclear Medicine
- Service Note 43630_1 Jan/06 Infinia Heavy collimators tooth edge effectNuclear Medicine · 43630
- Service Note 43597_1 Jul/05 Millinnium CSE Detector Plastic Seals For X-tal Frame NutsNuclear Medicine · 43597
- Part number required for the VG detector bushing where the collimator guide pin seatsNuclear Medicine
- Intermittent reverse pixels in high contrast Nuclear images (pixel burnout) on Powerstation LNX when sent to a 8700 Kodak laser imager.Nuclear Medicine
- When launching Service Virtual Assist (SVA) tool from VOLC, it fails to display password prompt.Nuclear Medicine
- Part number required for tuning source vial for XCXR, AC and CSE detectorsNuclear Medicine
- Part number required for the ESD safe Vacuum cleanerNuclear Medicine
- Part number required for the filter used in the ESD safe Vacuum cleanerNuclear Medicine
- What is the maximum Infinia table weight limit?Nuclear Medicine
- Unable to perform a Workstation Backup from the Configuration windowNuclear Medicine
- CSE detector DUI I/N Board Diagnostic each of the (10jx) 159, (10kx) 160, (10lx) 161, (10mx) 162 part tests reports errorsNuclear Medicine
- Need a part number for the switch bar on the patient cradle handle assembly for a Maxxus table.Nuclear Medicine
- Need to know conversion for Torque specification from Nm to pound feet or pound inch.Nuclear Medicine
- Need an Updated NM Equipment & UPS Cross Reference Matrix (UPS products used in Nuclear)Nuclear Medicine
- What TCP ports need to be open for broadband connectivity - GEHC-IT VPN Parameters & Protocols?Nuclear Medicine
- Customer request to download eFlexTrial software licenses key generation fails when downloading from the eFlexTrails Center websiteNuclear Medicine
- When the modality worklist entry is added to the Genieacq To Do list, none of the scans for the matching protocol are added.Nuclear Medicine
- High frequency noise coming from the 9125 2KVA Powerware UPSNuclear Medicine