GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 28 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Need part number for Starcam XC/XR and Maxxus Turbo Preamp Assembly.Nuclear Medicine · 2171428, 212011743
- Service Note 43161_0 Jun/99 VGH, Four New Classes (gain range) of 3" Hamamatsu PMTNuclear Medicine · 43161
- Service Note 43541_2 Jan04 All Elscint Ring Gantry ActuatorsNuclear Medicine · 43541
- Service Note 43535_0 Jul/04 Powerstation LNX Networking xinetd, intermittent communications or “drop out” between LNX and XT.Nuclear Medicine · 43535
- Service Note 43543_1 Jan/04 Helix Collimator Cart Wheels Verification ProcedureNuclear Medicine · 43543
- Defibrillating a patient on the Millennium MG/MPR patient table.Nuclear Medicine · 212004179
- Part number required for Infinia / VG Table BumperNuclear Medicine · 212004179
- Infinia RDA troubleshooting guideNuclear Medicine
- Service Note 43413_0 Dec/02 Unable to Loosen SPx / CardiaL Actuator NutNuclear Medicine · 43413, 40728
- Service Note 43440_1 Mar/03 Phillips 60 mm PMT s for SP-HR and CardialNuclear Medicine · 43440
- Customer wants to use their existing IVY biomedical model 101T ECG gating deviceNuclear Medicine · 212020476
- Service Note 43457_1 Oct/03 ACQ 7.7.19, 7.9.7 & 8.0.2 Software UpdatesNuclear Medicine · 43457
- Service Note 43430_0 May/03 Counterweight Upgrade iSeriesNuclear Medicine · 43430
- Service Note 43426_4 Apr/07 LCS, Optimized LCS and LOPCO/REMA Board InformationNuclear Medicine · 43426
- When selecting DST STP3 (SMV Camera) from Xeleris Source caused Einstein Error and Xeleris crash during network data transfer.Nuclear Medicine · 212010031
- Infinia ASM001150 rotation gear mounting torque specifications are not publishedNuclear Medicine · 212004100
- What are the software revisions and patches for SMV cameras?Nuclear Medicine
- Service Note 43424_0 Mar/03 Installation des cadres autocontour (French Version)Nuclear Medicine · 43424
- Service Note 43423_2 Aug/06 DST-XL Autocontouring frame installation updateNuclear Medicine
- Codonics NP1600 / NP1660 ribbon sensor malfunction, No Ribbon and Check Ribbon error messages.Nuclear Medicine
- Part number required for description MOBIL GREASE 28, COLOUR REDNuclear Medicine
- Second Opinion Part 2199420 Swivel Assembly Head #1 or 2199421 Swivel Assembly Head #2Nuclear Medicine · 2199420, 2199421
- Genieacq acquires then terminates after only one second on Uniformity, COR, and Camunif calibration acquisitions.Nuclear Medicine · 212009819
- Need information on dbtool, the command line database tool for Genieacq.Nuclear Medicine · 212004179
- Why do we add 1000 to the traditional Hounsfield Unit, when we report our Hawkeye CT numbers during Acceptance Testing?Nuclear Medicine · 212004179
- Part number required for Key switch (S4) in the control panel of an iSeries system.Nuclear Medicine · 212020476
- Service Note 43628_2 Jul/06 Genieacq SuperMicro Computer, new PC platformNuclear Medicine · 43628
- Service Note 43629_1 Jan/06 Infinia II 2.5 Software SIS Service Information Sheet Version 2.005.005Nuclear Medicine · 43629
- Part number required for Monitors or LCD flat panel display used on Nuclear systems.Nuclear Medicine · 212011100
- Lost Bios settings due to bad battery on SMV Sopha Bridge PC.Nuclear Medicine
- Unable to acquire Genieacq Second Order Correction (SOC) file for any Isotope.Nuclear Medicine
- No Gantry motions, fails to calibrate without moving.Nuclear Medicine
- Part number required for VGACQ PCI and EISA versions of MFB and MAB acquisition boards.Nuclear Medicine
- From recent information a number of field engineers are having difficulty recognizing if FMI 40788 (VG MUGA patch) has been loaded correctly.Nuclear Medicine · 40788
- How to instruct customer to initiate Tip Virtual Assist (TVA ) also Service Virtual Assist (SVA), for insite remote accessNuclear Medicine
- What is the Bore width (gantry ring tube opening) of the Infinia / VG / Helix GantryNuclear Medicine · 212019705
- How to delete duplicate customer User Acquisition Templates on GenieAcq?Nuclear Medicine · 212020452
- Service Note 43380_0 Dec/02 Power Station LNX Parts ListNuclear Medicine · 43380
- Service Note 43390_1 Jun/02 New PC Platform for IB XC_XCR SystemNuclear Medicine · 43390
- Part number required for adjustable hinge for mounting ADAM/DOC assembly in VG detectorNuclear Medicine · 212004179
- Color screen capture from Xeleris will not allow for windowing and color change on CRENER PACS display, B&W format will allow this on this PACS systemNuclear Medicine · 212004179
- iLinq browser is missing Service and Applications iconsNuclear Medicine · 212004179
- How to configure the VGH system for Insite Broadband connection.Nuclear Medicine
- Gantry init................................... never completes after 16 dots just keep goingNuclear Medicine · 212020476
- Second Opinion Part 9CRY0089-A Optima CrystalNuclear Medicine
- VG MCH-V card PCA000492 With new PCA000492 fitted in old VariCam's error in rotation will occur during Tomo Step and shoot.Nuclear Medicine · 13066634
- Mandatory on Request FMI 40763 Vision LNX Powerstation 6.0, kits UPG001291 are shipped with a currently outdated revision of Direction 2354938-100, Rev 2 producing an incorrect installation of LINUX O…Nuclear Medicine · 40763, 2354938
- FMI 40763_0 Nov/02 Vision 6.0 for an LNX POWERstation Kit UGP001291Nuclear Medicine · 40763, 2354938
- ADAC Gated Spect and MUGA dataset for Blood Pool Gated Spect transfered to Xeleris via DirectConnect does not process.Nuclear Medicine
- Service Note 43223_1 Dec/00 New Collimator Cart Floor Plate ASM000862-01 for VG / Varicam SystemNuclear Medicine · 43223
- Infinia (or VG) Table and Gantry Motor Driver Identification (Elmo Driver)Nuclear Medicine
- While retrieving or archiving patient data from Xeleris (Entegra) archive CD, getting Out of Resource / Resource Full / Memory error Or, when archive job reports 80% complete, the source icon goes red…Nuclear Medicine
- On Genie P&R reboot, system displays the "Select (b)oot or (i)interpreterNuclear Medicine
- Unable to burn CD on Xeleris 1.1, Nero will not launch.Nuclear Medicine
- Part number required for the VG Collimator Cart in place micro switch.Nuclear Medicine
- How to procedure for XC-XR Measuring Preamp OffsetNuclear Medicine
- Network Connection Debugging Checklist - DICOM Configuration on XelerisNuclear Medicine
- On IBACQ Genieacq 4.0 Second Order Correction never updates the correction file even though it seems to complete and store normally.Nuclear Medicine · 212004014
- Database does not resize after creating databaseNuclear Medicine
- Millennium VG Parts ID NotebookNuclear Medicine
- Infinia II Parts ID NotebookNuclear Medicine
- MG/MC/Myosight Parts ID NotebookNuclear Medicine
- MG Gantry shudders or vibrates during rotationNuclear Medicine
- What are the GenieACQ File Backup / Restore Options in st_bru?Nuclear Medicine
- VG / Infinia table starts to move up or down very fast out of control and then the gantry reports error #167 max dac.Nuclear Medicine
- RDA - Not to check the ability to send data - How to check the ability to send dataNuclear Medicine
- Part number required for MG Pin Hole Collimator PSD Switch AssemblyNuclear Medicine
- How to replace HP Surestore 5200 MOD with Sony SMO-551 MODNuclear Medicine
- Infinia MEGP/HEGP/UHEHR Collimators Cookie cutter edge artifact (toothed edge pattern) on flood imageNuclear Medicine
- GenieAcq System files, Utilities, Functions, Commands and LocationsNuclear Medicine
- Cheat Sheet Genie (Solaris) Cheat-Sheet System files, Utilities, Functions, Commands and LocationsNuclear Medicine
- Part number required for Infinia table front indexing diskNuclear Medicine · 212004100
- How to find information on EOPL (End of Product Life) for Nuclear systems.Nuclear Medicine
- How to ftp multiple files without user confirmation when using mget command.Nuclear Medicine
- Part number required for Infinia Swivel Motor PulleyNuclear Medicine · 212004100
- PSDB Help -- Using PSDB NM Knowledge Online / Offline Key Word Search Guide -- PSDB HelpNuclear Medicine · 44444
- Mystery Interrupt error when booting from Polestar SCSI system Start-up disk.Nuclear Medicine
- Part number required for VG or Infinia ECG signal (coax) cable (connects ECG Gate device to acquistion computer)Nuclear Medicine
- Part number required for VG and Infinia table up down drive shaft flexible couplingNuclear Medicine
- Part number required for the new Hawkeye TTH Single Slice Generator components (Not for Chiron - Hawkeye 4)Nuclear Medicine
Full cause & resolution for every GE Nuclear Medicine issue
Unlock the complete cause analysis, step-by-step resolutions and attached service documents — re-authored, web-first, searchable.