Service Note 43633_1 Feb/06 Motion II ver. 2.0 Software for VG Systems
Symptom
Service Note 43633_1 Feb/06 Motion II ver. 2.0 Software for VG Systems • Stopped on unknown during bed movement from NM scan to CT scans. • Velocity issues in HWK DLQC in L-Mode • Error #23 during Spect Acquisition • Error #167 during Collimator Exchange • Error #144 when table moving in for Hawkeye scan. Service Note 43633 _1 Feb/06 Motion II ver. 2.0 Software for VG Systems Background: GE Healthcare have been notified of the following errors which sometimes occur: • Stopped on unknown during bed movement from NM scan to CT scans. • Velocity issues in HWK DLQC in L-Mode • Error #23 during Spect Acquisition • Error #167 during Collimator Exchange • Error #144 when table moving in for Hawkeye scan. Notes: This patch must be installed on systems having a 5197979 MCH board mailto:[email protected]
Error message
Error #144 (Error 144) Velocity test fail axis = $ Axis # Axis Name 0 Lateral 1 Radial #1 2 Radial #2 3 N/A 4 N/A 5 Swivel #1 6 Swivel #2 7 Rotation 8 Linear 9 Height Error #23 (Error 23) Software failure send buffer Error #83 (Error 83) DRIVERS VOLTAGE TEST: SSR control bit mismatch Error #167 (Error 167) Max Dac Command Axis = $ Axis # Axis Name 0 Lateral 1 Radial #1 2 Radial #2 3 N/A 4 N/A 5 Swivel #1 6 Swivel #2 7 Rotation 8 Linear 9 Height
Applies to
- Product
- VGH VG and VG Hawkey and Varicam
- Software
- VGH 6.0 VGH Acq 6.0 VG Acq 6.0 Part #: UGP001355 VG/DVG VER.6 KIT FOR SPARE PART (also see additional requirements below) Includes Software LSW000398 VG DVH HAWKEYE VER. 6 SW PACKAGE: Engineering Bill of Materials Name Description LSW000382 VG VH HAWKEYE Ver. 6 SW CD LSW000312 RCU for Dell 1400SC LSW000332 DISKETTE 1 SYSTEM LSW000403 Ver 6.0 Supplement 12 patch ver 6.0 build 7.5 (SN43633) LSW000426 VG Ver. 6 Motion and Worklist Patch.(SN43524) Also Includes: Software LSW000333 SOFTWARE PACKAGE FOR OLD COMPUTER VG: Engineering Bill of Materials Name Description LSW000011 DISKETTE 1 SYSTEM LSW000203 CKERMIT for GX200 LSW000022 SOFTWARE DELL ECU DISKETTE LSW000101 RCU for DELL 1300 ESW000637 HPC-HP 3COM LSW000404 DISKETTE 1 SYSTEM For HP NetServer Dell 2200 In addition VG requirements : UGP001583 VG Ver. 6.0 MUGA Patch LSW000490, FMI 40788 5195796 VG CoDe 2 Cold Spot, FMI 40805, CODE system only. 5169077 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633 Optional: 5169169 Service Pack # 5169169 Q3 ver 2.0, SN43632
- Component
- *Software Software Software 5168896 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 5168896 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Muga patch FMI 40788 when loaded does not indicate it completed
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Part number needed for Optima E-Stop
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- Need part numbers for the Millennium MG/MC table E-Stop