GE Nuclear Medicine — field troubleshooting
3,436 field-service issues · page 35 of 43
Symptom, error message and equipment context for each GE Nuclear Medicine issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- I need the part number for the acquisition CPU on a Starcam Polestar.Nuclear Medicine
- I need the part number for the acquisition power supply in a Starcam PolestarNuclear Medicine
- Need the part number for the transceiver and receiver pieces of the Automatic Body Contouring (ABC) option on a MG gantry ring.Nuclear Medicine
- Need part number for MG/Myosight collimator Cart Lock Pin KeyNuclear Medicine
- What are the software revisions and patches for - Ventri?Nuclear Medicine
- While manually moving the Infinia Table Pallet with release handle, getting Error # 144 VELOCITY TEST FAIL AXIS = 8 Table LinearNuclear Medicine
- Infinia database runs out of available space without notifying the user.Nuclear Medicine
- Need a part number for the cover that goes over the VG / Infinia table clutch handle (also known as cart cover)Nuclear Medicine
- Is it ok to put Nuclear Medicine equipment on an emergency backup generator circuit?Nuclear Medicine
- What are the part numbers for the Starcam Polestar A/N and Image Monitor Scan EHT boards?Nuclear Medicine
- Xeleris 2 (M4) 2.0523 Application Notes and WorkaroundsNuclear Medicine
- Starcam Polestar (4000IAP, Maxxus, and Optima) 46-324174P1 (T3415XK ) HighRes Image Monitor ReplacementNuclear Medicine
- Unable to configure Infinia Gantry P-Scope displayNuclear Medicine
- Infinia Gantry GReset fails first thing in the morning with Error #155 on Axis 8 Linear, also on Axis 5 or 6 Swivel.Nuclear Medicine
- How to configure the Xeleris for a Kodak 8300 Dicom PrinterNuclear Medicine
- Infinia II Hawkeye 4 (HE4 Chiron) Recommend Spare Parts List (RSPL)Nuclear Medicine
- MPR which when going to the preprogrammed motion (PPM) "under the table'" position, the detector Tilt position is not at zero (0) degrees.Nuclear Medicine
- Service Note 43709_1 Dec/06 Microsoft Security Patch for Infinia I MS06-070, MS06-035, MS06-036, MS06-040Nuclear Medicine · 123748
- Service Note 43661_2 Jan/08 Backup and Restore Scripts for Vision POWERstations running 6.0.0 or subsequentNuclear Medicine · 43661
- Part number 300443 Info Motherboard backplane (Rack1) use on DS7/DSX 1000 series gantry has been changed.Nuclear Medicine · 300443
- Unable to start TIP Virtual Assist (2getin login fails, user not recognized)Nuclear Medicine
- Unable to load new software on 2347614 Genieacq Dell GX200 Computer, boots Installation Boot floppy, prompts for Utilities floppy but then is locked up.Nuclear Medicine · 2347614
- Part number 300513 PWD Backplane for DS7/DSX 1000 series gantry is no longer available.Nuclear Medicine · 300513
- Ventri System will not Initialize motions on power up - Low level ethernet communication errorNuclear Medicine
- Daylight Saving Time (DST) Customer CommunicationNuclear Medicine
- What are the Image data file sizes for Nuclear and PET data?Nuclear Medicine
- When ordering the detector board mounting plate, the part does not have holes for mounting the cooling fans.Nuclear Medicine
- SMV DS Camera Auto transfer is slow or does not transfer at all.Nuclear Medicine
- I need a complete list of cable part numbers for the Ventri table.Nuclear Medicine
- I need technical support on the Powerware UPS.Nuclear Medicine
- Inspector needs to know if the Gamatronics 3 phase UPS is a separately derived system as described in the NEC (National Electrical Code).Nuclear Medicine
- During Xeleris 1.1330 software installation on XW6200 (Spare Part 5142394 or 5146259 – a Replacement for XW4100), while loading Image Add On CD, the Exceed program does not appear on the menu selectio…Nuclear Medicine · 5142394, 5146259
- I need the part number for a 3 button mouse used on a Genieacq computerNuclear Medicine
- How do I find the patient name used in a Starcam user protocol?Nuclear Medicine
- I need the infinia Fox Pop board part numberNuclear Medicine
- I need the part number for the Ventri collimator T-handle.Nuclear Medicine
- Maxxus Table will not Move or Calibrate, and is Not on any limit switchesNuclear Medicine
- What are the Infinia software revisions and Windows patches?Nuclear Medicine
- Workstation will not reconstruct any type of raw tomoNuclear Medicine
- When initializing Ventri, operator can't disengage the clutch to pull table pallet outNuclear Medicine
- Xeleris/ Entegra gives error that "Event Log is Full" or near full, during bootup, or processing or displayNuclear Medicine
- Genie HP715 and Genie Solaris date Time change (DST) Daylight Saving TimeNuclear Medicine
- Need part number for Ventri Norav ECG patient cableNuclear Medicine
- Service Note 43702_1 Mar/07 Time Changes on Vision Systems - AIX POWERstations and FX Cameras, Vision Acquisition Stations, Hitachi SystemsNuclear Medicine · 125338
- Need part number for Ventri GCUNuclear Medicine · 212010832
- Need replacement part number for Starcam (Sony) Alpha Numeric (A/N) or IMAGE Monitor when original P/N no longer available.Nuclear Medicine · 2333553, 2133532
- Daylight Saving Time (DST), Date and Time Change for NM Products Cheat Sheet.Nuclear Medicine
- Service Note 43726_2 Mar/07_Adjusting the Daylight Saving Time (DST) on Windows XP NM WorkstationsNuclear Medicine · 125468
- Need the correct table travel distance (clearance) at maximum extension for Myosight.Nuclear Medicine · 2355311
- Need part number for operator's console cart casters (set of 4) for DST-XL/Xli/Xi/DSTi/DsiNuclear Medicine
- Starcam Build StandardNuclear Medicine
- The 1x2 format is not available -is greyed outNuclear Medicine
- Need the MPR/MPS A1 regulator board PCA000501 adjustment test pointsNuclear Medicine
- How to configure Xeleris for Codonics as a windows printer (in addition to Xeleris application configuration) for jpeg files etc.Nuclear Medicine
- Worklist query fails -unknown job statusNuclear Medicine
- Unable to start acquisition on Infinia due to "gantry not ready" messageNuclear Medicine
- Need to know the catalog number for the OSI option and requirements for Xeleris to network to Starcams and Elscint systems via ethernet.Nuclear Medicine
- When entering the Xeleris application an error window opens stating "Failed to Start Archive Card"Nuclear Medicine
- Maxxus IPS Voltage Regulator Board test pointsNuclear Medicine
- Service Tool - Need tool part number for the linearity phantom kit for VGNuclear Medicine
- Computer reports database offlineNuclear Medicine
- Need part number for MG/MC/Myosight detector cable that connects the detector to the gantry cable chainNuclear Medicine
- Need part number for touch up paint or physical damage to system requires touch up paintNuclear Medicine
- Not able to delete printing queue from PowerstationNuclear Medicine
- Millennium motion Sequence FailureNuclear Medicine
- Customer wants both Remote Database and DICOM configured for the same remote station.Nuclear Medicine
- Service Tool - Need part number for Helix moving kitNuclear Medicine
- Auto Processing feature on Infinia will not launch on the XelerisNuclear Medicine
- Powerstation software license key will not loadNuclear Medicine
- Can not adjust screen saver to for longer wait time (or need to turn off the screen saver)Nuclear Medicine
- Millennium Non-uniform flood image (tube out), but improves after 2-3 minutes.Nuclear Medicine
- DS camera will not boot, No characters on the displayNuclear Medicine
- How do I replace the Infinia Pinhole collimator insert?Nuclear Medicine
- Xeleris / Entegra Application hung on patient database verification or connecting to database, Application does not boot.Nuclear Medicine
- Xeleris / Entegra Application bootup is hung on Archive database verificationNuclear Medicine
- Part number required for detector high voltage power supplyNuclear Medicine
- Part number required for MG/MC/Myosight collimator cart docking switch / receptacleNuclear Medicine
- How to find software revision and patches on - Powerstations?Nuclear Medicine
- Getting message "Cannot prepare archive handler" when stating acquisition on VG.Nuclear Medicine
- How to watch Genieacq detector tuning updates during tuning iterationsNuclear Medicine
Full cause & resolution for every GE Nuclear Medicine issue
Unlock the complete cause analysis, step-by-step resolutions and attached service documents — re-authored, web-first, searchable.
Start free trial7-day free trial · no credit card required