Pular para o conteúdo principal
WarningCalibration & Sensitometry Files

HC11310Image cannot print — incompatible film sensitometry (New/Default.FMsen) file

Agfa CT error code, reported by the Calibration Files.

What HC11310 means

On DryStar 5500 (Type 5364/100) and DryStar 5503 (Type 5364/300) CT systems, status code HC11310 indicates: Image cannot print — incompatible film sensitometry (New/Default.FMsen) file. The code originates in the Calibration & Sensitometry Files section of the Calibration Files. Severity level warning (Warning).

Reported action: Perform a film calibration from the tray you wish to print from..

Raised on the Drystar 5500/5503 when an image cannot be printed because the New.FMsen or Default.FMsen film sensitometry file on the hard disk is incompatible with the installed software release. Documented in the appendix's film/TH calibration-file compatibility block alongside HC11303 and HC11309.

Full troubleshooting for HC11310

The complete diagnosis, cause tree, and step-by-step remedy for the Calibration & Sensitometry Files subsystem are documented in the FSELIB Activion16 (TSX-031A) service manual — re-authored, web-first, with real figures.

Open the Activion16 service manual

Related Calibration & Sensitometry Files codes

Discuss HC11310 with other field engineers in the FSELIB forum

Source: AGFA DryStar service manual — HC error catalogue (FSELIB authored corpus). Reference information re-authored by FSELIB — not a copy of the OEM manual.