On DryStar 5500 (Type 5364/100) and DryStar 5503 (Type 5364/300) CT systems, status code HC11310 indicates: Image cannot print — incompatible film sensitometry (New/Default.FMsen) file. The code originates in the Calibration & Sensitometry Files section of the Calibration Files. Severity level warning (Warning).
Reported action: Perform a film calibration from the tray you wish to print from..
Raised on the Drystar 5500/5503 when an image cannot be printed because the New.FMsen or Default.FMsen film sensitometry file on the hard disk is incompatible with the installed software release. Documented in the appendix's film/TH calibration-file compatibility block alongside HC11303 and HC11309.