HC11255 — Middle-tray pick-up passed-sensor timeout (sensor S19)
Agfa CT error code, reported by the Film Tray Pick-up (Jam & Suction Timing).
What HC11255 means
On DryStar 5500 (Type 5364/100) and DryStar 5503 (Type 5364/300) CT systems, status code HC11255 indicates: Middle-tray pick-up passed-sensor timeout (sensor S19). The code originates in the Film Tray Pick-up — Jam & Suction Timing section of the Film Tray Pick-up (Jam & Suction Timing). Severity level alarm (Alarm).
Reported action: Open the middle input tray and remove any jammed sheet between the tray and sensor S19; if this keeps recurring, look for a mechanical blockage of sheet transport. If the jam clears but the fault persists, power off the printer, check that S19 is correctly positioned, and reposition or replace it as needed..
Raised on the Drystar 5500/5503 when no sheet triggers the middle pick-up "passed" sensor S19 within the time-out limit after a middle-tray film pick-up. Filed alongside the other pick-up jam and suction-timing codes for the upper, middle and lower trays.
Full troubleshooting for HC11255
The complete diagnosis, cause tree, and step-by-step remedy for the Film Tray Pick-up — Jam & Suction Timing subsystem are documented in the FSELIB Activion16 (TSX-031A) service manual — re-authored, web-first, with real figures.
Open the Activion16 service manualRelated Film Tray Pick-up — Jam & Suction Timing codes
Source: AGFA DryStar service manual — HC error catalogue (FSELIB authored corpus). Reference information re-authored by FSELIB — not a copy of the OEM manual.