GE X-ray R&F — field troubleshooting
3,432 field-service issues · page 20 of 43
Symptom, error message and equipment context for each GE X-ray R&F issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- DRS with MS90 camera, needs signal generator board with extendeer board, needs partsX-ray R&F
- Fluoro focus is off, rad exposures are OKX-ray R&F
- DRS Repro Alarm 10 Error with Sterling Laser.X-ray R&F
- DRS Laser camera interfaceX-ray R&F
- DRS Repro Error Alarm Code 19, LINX Cannot Capture Image AlarmX-ray R&F
- DRS Artifacts in Printed Films, OnlyX-ray R&F
- DRS Port Number for Hospital NetworkX-ray R&F
- DRS Repro Error Alarm Code 19, LINX 'No Study Open for Host Control Session' AlarmX-ray R&F
- DRS Repro Error Alarm Code 19, LINX "Cannot capture Image Alarm"X-ray R&F
- DRS 3.2 with 9.1GB Seagate ST39175LC Disk Drive replacement issueX-ray R&F
- No video on DRS but conventional fluoro is fine.X-ray R&F
- DRS 3.2 Patient directory is not displayed.X-ray R&F
- DRS Image not printing in reverse video from DRS GatewayX-ray R&F
- DRS with DRS Gateway "Remote server application not responding" Error MessageX-ray R&F
- DRS Gateway images will not transfer from the Gateway to the DICOM printerX-ray R&F
- DRS Gateway sent images to Dicom Printer Not in OrderX-ray R&F
- DRS P1 2.34 Intermittent Dark Images, locks up after 26 imagesX-ray R&F · 940005, 2107118
- DRS Gateway pcAnywhere Does Not WorkX-ray R&F
- DRS FMI 10690 500 images max after upgrade Fujitsu M1603 is only 545 megX-ray R&F · 10690
- DRS E3 error in the MHR cabinet motherboard hex display and console not coming up.X-ray R&F · 54553
- DRS Mother Board Error 47 and gel board haltsX-ray R&F
- DRS GEL, GELMFC & IMA Red LED Lights at Bootup, Major FailureX-ray R&F
- DRS slow network transfer to RADWORKS 10sec/image, 50 sec wait.X-ray R&F
- DRS Legacy FMI 10690 How to display the dictionaryX-ray R&F
- DRS Basic cannot draw ROW boxes with laptopX-ray R&F
- Laptop hookup to DRSX-ray R&F
- DRS Laptop Cable Part NumberX-ray R&F
- DRS Power Supply for 3.1 is different than 2.2, but are interchangeableX-ray R&F
- DRS How To Adjust Power Supply VoltagesX-ray R&F
- DRS Console partX-ray R&F
- DRS Second console option - max length of cable from DRS to 2nd console and part numbersX-ray R&F
- DRS Console contines to beep after boot upX-ray R&F
- MVP3 Error 14 when rotor is startedX-ray R&F
- MVP3 Error 24 at prepX-ray R&F
- MVP3 Errors 33 and 23, intermittentlyX-ray R&F
- DRS 3.1 Max distance without Wall Box.X-ray R&F
- DRS Disk Drive ReplacementX-ray R&F
- DRS VIC no Last Image Hold Fluoro, Conventional Fluoro OKX-ray R&F
- GPX DRS Service ModeX-ray R&F
- DRS Performed the DRS 2.0 to 2.2 upgrade now the images are blackX-ray R&F
- DRS Fluoro image darker than Fluoro imageX-ray R&F
- MPX kv servo inconsistent.X-ray R&F
- MPX No mA display no tube select large / small spot lights stay on Address 3959 load 51X-ray R&F
- MPX Generator O/L on (900 HZ Tone)X-ray R&F
- MPX 105 Photospot Camera Doesn’t ExposeX-ray R&F
- MPX Tool Auto Cal Mode Does Not Cal Large SpotX-ray R&F
- MPX halts unexpectedly.X-ray R&F
- MPX No fluoro KV overrideX-ray R&F
- MPX Service Note 3629 problem with 4 k Battery Memory BoardX-ray R&F
- MPX Voltpak oscillating in ABC.X-ray R&F
- MPX L300 collimator blades closed in fluoroX-ray R&F
- MPX New Ion Chamber installX-ray R&F
- MPX Tool DirectionsX-ray R&F
- MPX SFX will not angulate unless horizontal stop switch is offX-ray R&F
- 88SFD, MPX System.X-ray R&F
- MPX MG2A6A31 Rotor Controller Sequence Board 46-188890G1X-ray R&F
- MPX Line RegulatorX-ray R&F
- MPX HV Transformer PL1, PL2, PL3 amperage readings.X-ray R&F
- MPX X-ray MPX Database Tool install failsX-ray R&F
- MPX Does not turn on.X-ray R&F
- MPX SPX Console blanksX-ray R&F
- MPX SFD Photimed (PT) exposureX-ray R&F
- MPX The system locked up.X-ray R&F
- ADX LFX and MPX voltpac pot replacement.X-ray R&F
- MPX Info on interface kit for MPX to Ordogrpahy SystemX-ray R&F
- Video system programmer 2 (MX1 A5 A2) information.X-ray R&F
- MPX Intermittant heat storage wait and the attention messages flash on the monitorX-ray R&F
- MPX CalibrationX-ray R&F
- The laptop tool loads FF's to all locations when doing a database restore.X-ray R&F
- MPX tube selectionX-ray R&F
- MPX AEC exposures erratic with chest standX-ray R&F
- MPX The safety contactor does not energize. -15V power supply missingX-ray R&F
- MPX Relay MG3A2K15 in the SARC cube turns off and on at about 3 times/second after power on.X-ray R&F
- MPX SPX No mA during fluoro or RAD exposure.X-ray R&F
- MPX Generator Rad mA calibration problemsX-ray R&F
- MPX Phase 3 control panelX-ray R&F
- MPX Not terminating exposuresX-ray R&F
- MPX Not forced commutating, exposure is terminated by safety contactor.X-ray R&F
- MPX locked upX-ray R&F
- MPX At the console the KVP button not responding, the mAs is slow, and the mA is slowerX-ray R&F