98438 Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.

Symptom

Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76

Error message

INX100: 3602038 IH XRTechMgr Jedi: kvctl configuration problem JEDI Error Code: 0701H Saved RAM checksum pb 3602038 IH XRTechMgr Jedi: kvctl configuration problem Debug: jedi-error-code=701h JEDI Error Code: 0701H Saved RAM checksum pb Data Related to Error: 0 Tube 1 70C: OK, Tube 40C: OK, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY Generator PPC kV control board has detected corruption in the NV Ram verification (After power up)

INX100: 3602075 Jedi: Unkwnon Inhibit error; Generic error ''Generic_class4'' reported for JEDI Error Code: 0557H 3602075 Jedi: Unkwnon Inhibit error IH XRTechMgr acquisition Jedi_Unknown_IH_error 0 0 JEDI Error Code: 0557H Generic error ''Generic_class4'' reported for JEDI Error Code: 0557H Data Related to Error: 144 Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: POW XRPAtlasLogger.cpp 156 Jedi Error 557H - Root Cause: LVPS TRI: Detected +160V too low +160V is lower than 110V (measured on heater board). 3602075 Jedi: Unkwnon Inhibit error IH XRTechMgr acquisition Jedi_Unknown_IH_error 0 0 JEDI Error 

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Component
Innova Jedi Innova Jedi Innova Jedi
Area
X-ray Vascular

Full cause & step-by-step resolution