GE Healthcare · X-ray VascularInnova1200107130010112001011200112
Innova System boot failure Any defect that prevents from getting the first acquisition after the system reset.
Innova System boot failure
Symptom
Innova System boot failure Any defect that prevents from getting the first acquisition after the system reset. Customer needs to boot again to recover. When Innova system has a actor issue.
Error message
1200107 (Frontal) 1300101 (Lateral) ERR_Conditioner_Boot_Failure 1200107 (Frontal) 1300101 (Lateral) ERR_Conditioner_Boot_Failure. 1200107 (1300101): Root Cause: Component(s) - Frontal (Lateral) Conditioner This error is due to time out on Communication to the frontal (lateral) Detector Conditioner or bad status returned by Conditioner. 1200107 (Frontal) - 1300101 (Lateral) ERR_Conditioner_Boot_Failure 1200107 (1300101) : Root Cause: Component(s) - Frontal (Lateral) Conditioner This error is due to time out on Communication to the frontal (lateral) Detector Conditioner or bad status returned by Conditioner. 1200101 Link between IDC and the conditioner is down. 1200101 ERR_CONDITIONER_COM DO XRImDet DEM Component(s)_RTAC_Conditioner_serial_link 1 0 [DemSupervisor::_handleConditionerCommunication] Link between IDC and the conditioner is down DemSupervisor.cpp 1063 1200112 ERR_CONDITIONER_BOOT_WARNING . Conditioner boot warning. sn4764 DIPB oscillator preventive check 1200112 ERR_CONDITIONER_BOOT_WARNING . Conditioner boot warning 1200112 ERR_CONDITIONER_BOOT_WARNING . Conditioner boot warning. See sn4764 DIPB oscillator preventive check
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Detector conditioner 5131740 SMC detector conditioner Detector conditioner Current rev is -15 but a -7 through -15 is acceptable. Detector Conditioner, connecter kit 2379172 5131740 SMC detector conditioner Detector conditioner Current rev is -15 but a -7 through -15 is acceptable. Detector Conditioner, connecter kit 2379172
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.
- DL system hangs while customer trying to change protocols