GE Healthcare · X-ray VascularInnova
The system reports "Internal Software Error" when performing QAP or IQST
Symptom
The system reports "Internal Software Error" when performing QAP or IQST
Error message
QAP/IQST fails. Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error. Review the results.html file for the failed test. If some some (or all) of “Composite phantom” measurements in the IQST results file, starting with “Lateral MTF at 2.0 lp/mm 20cmFOV”, provide “NODATA, missing measurement” error. The system is not properly detecting the composit phantom. Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error. Review the results.html file for the failed test. It can be found in c:\Program files\ GE Medical Systems\IQST\ Scratch or c:\Program files\ GE Medical Systems\IQST\archive\xxxDatexxx. If some (or all) of “Composite phantom” measurements in the IQST results file, starting with “Lateral MTF at 2.0 lp/mm 20cmFOV”, provide “NODATA, missing measurement” error. The system is not properly detecting the composite phantom. Innova: QAP / IQST error log indicates "Sorry, the system had problems detecting certain critical features in the phantom image. Please check the phantom orientation and acquisition paramet
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.