GE Healthcare · X-ray VascularInnovaAdvantx30068

IThe Customer complains of a Water or a fluid leak on the system.

Symptom

The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. If zero stock on 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next. The Customer complains of a Water or a fluid leak on the system. The customer indicates there is water leaking from the closed loop cooling system. Fluid is coming out of the tube arm assembly or in the technical room. 2184070-2 RP ROTATING JOINT then order 2129844-2 RIGID WATER COOLING ASSEMBLY and it contain the joint part. Also replace the two O-rings with new or they will leak next

Error message

IN2K, Advantx, 41B4, 42FB, 30068:Tube casing water flow not detected IN2K, Advantx, 41B4, 42FB, 30068:Tube casing water flow not detected: This error does not inhibit Xrays. If the water flow issue is not address, the XRT could overheat enough to open the >70 degree C switch on the XRT, the error 42FB is then generated and time has to be allowed for the XRT to cool. Error 30068 is generated on an Innova 2000 system. IN2K, Advantx 41B4, 42FB, 30068: Tube casing water flow not detected: This error does not inhibit Xrays. If the water flow issue is not address, the XRT could overheat enough to open the >70 degree C switch on the XRT, the error 42FB is then generated and time has to be allowed for the XRT to cool. Error 30068 is generated on an Innova 2000 system.

Applies to

Models
Innova, Advantx
Product
Innova 2000 Innova 2000 systems Innova 2000 systems Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx, LFX Advantx product line LFX Advantx product line
Component
Positioner Gantry Positioner Gantry Positioner Gantry
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues