Unable to Run DQA Calibration Tool.
Symptom
Unable to Run Automated DQA Calibration Tool See Long Description and Attachment. It Fails With Error Message "Wrong imaging parameters for Isocenter-Z calibration" or "Wrong imaging parameters for Gradient [X or Y or Z] field calibration" iTrak #s 13155738 and 13154170: The Automated DQA Calibration Tool opens normally with a menu selection of Auto or Manual. The tool then presents a choice of Isocenter-Z, or Gradient X, Y, Z or ALL. Following proper set-up for the coil and DQA phantom, the tool configures the scan for the selected mode and scans. The Automated DQA Calibration Tool then gives the following error depending on the mode selected: (See Attachment for a screenshot) Wrong Imaging Parameters for Isocenter-Z calibration FOV: 24cm Acq. Matrix: Freq. ->512, Phase->256 Freq. Direction: A/P Wrong Imaging Parameters for Gradient [X or Y or Z] field calibration FOV: 24cm Acq. Matrix: Freq. ->512, Phase->256 Freq. Direction: X=L/R, Z=A/P, Y=A/P Also, on a related note, after completion of SPT, there are no results reported at the end. By selecting the “WhatFailed” button on the bottom right of the SPT window, the following message appears: "Unable to find/open the output file." The SPT results can be viewed normally through Report Manager with the corresponding PASS, MARGINAL, SEVERE status
Error message
Wrong imaging parameters for Isocenter-Z calibration See Attachment for a screenshot. This message appears within the Automated DQA Calibration Tool See Attachment for a screen shot. This message appears within the Automated DQA Calibration Tool Wrong imaging parameters for Gradient [X or Y or Z] field calibration This message appears within the Automated DQA Calibration Tool This message appears within the Automated DQA Calibration Tool.
Applies to
- Product
- Open Speed with EXCITE For HFO4 and HFO5 only
- Software
- OPENMR5-HFO5 Open Speed with Excite Product
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.