GE Healthcare · MRExcite225434422543472254352
RF Amp Not Ready with Error Codes 2254347, 2254342, and 2254352 due to SRFD2 RF Amplifier.
Symptom
Will Not Scan With RF Errors Will not scan with RF errors
Error message
2254344 The RF Amp failed to respond to the AIF. 2254344 Host: lx-mr Process: NSP File: SCP:../rf_nb_serial Line: 1855 RF Amplifier Interface RF Amplifier serial link failure. The RF Amp failed to respond to the AIF. If the link is broken, a separate error message will be logged. 2254344 Host: lx-mr Process: NSP File: SCP:../rf_nb_serial Line: 1855 RF Amplifier Interface <-> RF Amplifier serial link failure. The RF Amp failed to respond to the AIF. If the link is broken, a separate error message will be logged. 2254347 RF Amplifier Interface RF Amp serial link failure. RF AIF failed to receive a packet transmission echo on 2nd try. If link is broke, a separate error message will be logged. If not, a spurious error occurred. Timer: 5080 Expired time: 40 Tx by 2254347 PAC3T NSP SCP:../rf_nb_serial 1947 RF Amplifier Interface RF Amp serial link failure. RF AIF failed to receive a packet transmission echo on 2nd try. If link is broke, a separate error message will be logged. If not, a spurious error occurred. Timer: 5080 Expired time: 40 Tx byte: M 2254347 PAC3T NSP SCP:../rf_nb_serial 1947 RF Amplifier Interface <-> RF Amp serial link failure. RF AIF failed to receive a packet transm
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Component
- SecondOpinion SRFD2 1.5T Solid State RF Amplifier 2351573 See comments in Resolution Concept for second opinion requirements before ordering this part. SecondOpinion SRFD2 1.5T Solid State RF Amplifier 2351573
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.