GE Healthcare · X-ray VascularInnova500145149233511985251198535001550125
INX100, IN2K, No Gantry / Table movements and No Lights on TSSC; FOV would work.
Symptom
INX100, IN2K, No Gantry / Table movements and No Lights on TSSC; FOV would work. Loss All Gantry/Table movements and No Lights on TSSC but FOV would work.
Error message
50014, error Text = POS : II COLLISION, debug Text /= pos-error=4A12, hw-status=0008, 2nd level bump System impact: Half speed until system level1 collision is cleared. Error message cleared following 2 seconds. Displayed message : "Detector collision: reverse motion to continue". A collision is detected on the bladder 4A12 with Hardware 0008 indicates a 2nd level bump, not a level 1 bump as indicated by this concept Bolus System, Install the Bolus M4+ (kit #5149233) on the system. BOLUS KIT 1 and 2 to replace SW package . 5119852 rev 7 BOLUS UPGRADE KIT 1 for INNOVA 4100 3100. 5119853 rev 7 BOLUS UPGRADE KIT 2 for INNOVA 4100 3100. 50014 WR VAS / POS POS : II COLLISION Debug: hw-status=4 pos-error=4a12 usr-status=0 POS ERROR=4A12,HDW STATUS=0004,USR STATUS=0000 error Code = 50015, error Text = POS : COLLIMATOR COLLISION, debug Text /= pos-error=4A13, hw-status=0010, usr-status=0000, recovery Class /= WR, major Function /= VAS / POS System impact: Half speed until system level1 collision is cleared. Error message cleared following 2 seconds. Displayed message : "Collimator collision: reverse motion to continue". error Code = 50125, hw-status=00A2, error Text = POS TSUI: SMB or SM
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.