Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
4000083 Arcnet chip is not ready to send a packet 4000083 Arcnet chip is not ready to send a packet. Will cause error 600105 Recommended Action: Check the 48V Martek Run RTAC subsystem//PCHost//Gitane_ARCNET_COM diagnostics. verify the power distribution in the Positioner (the Martek modules) check the ARCNET fiber from the RTAC to the positioner 4000080 GEB Drive failed to Xmit the packet ARCNET Communication 4000080 GEB Drive failed to Xmit the packet AR XRTitan logTitanError Component(s) ARCNET Communication 1 0 GebDriver local error code = 2 , error number = 3997698 Tif.cpp IN2K: Ping Test from Digital Leader to Titan Kernal Fails Ping Test from Digital Leader to Titan Kernal Fails. The Ping from the Digital Leader (DL) to the Titan fails. Attempt to ping the Titan Kernal from the DL. Open a command window and Ping 165.100.10.3. If The system reports "request timed out", The Ping to the Titan Kernal has failed
Applies to
- Models
- Innova, Advantx
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.